Search results for "Tears"
showing 10 items of 102 documents
Proteomics of tear fluid in thyroid-associated orbitopathy.
2012
Proteomics and mass spectrometry are useful tools for peptide screening in body fluids. In thyroid-associated orbitopathy (TAO), evidence for lacrimal gland involvement with altered composition of tears has been reported. Our objective was to detect and evaluate potential changes in the proteomic patterns of tear fluid in TAO.Tear fluid was collected from 45 patients with TAO and 15 healthy controls. Tear proteins were analyzed using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry, and peptides were identified using matrix-assisted laser desorption/ionization time-of-flight technology.Peptides with molecular weights 3808 Dalton (Da, p=0.004), 3734 Da (p=0.034),…
Longitudinal analysis of taurine induced effects on the tear proteome of contact lens wearers and dry eye patients using a RP-RP-Capillary-HPLC-MALDI…
2012
Tear proteomic studies revealed distinct similarities between contact lens wearers and dry eye patients. AMO Complete® multipurpose contact lens cleaning solutions containing taurine seem to have a beneficial effect regarding contact lens induced dry eye. To illuminate the effect of taurine on the tear proteome of contact lens wearers and sicca patients we developed a gel-based RP-RP capillary HPLC-MALDI TOF/TOF MS strategy. Two contact lens wearer groups, one using eye drops containing 0.05% taurine; the other for control physiological NaCl solution were monitored. Also, a third group of sicca patients using taurine solution was studied (N=4 individuals/group). Tear pools of each group at …
Response of the aging eye to first day of modern material contact lens wear
2018
Objectives: To investigate the ocular surface of an aged population wearing a daily disposable contact lens over their first day of wear. Methods: Forty eyes from forty presbyopic subjects were fitted a daily CL (Delefilcon A). Tear osmolarity, tear meniscus area (TMA) and ocular surface aberrations (total higher order root means square (RMS)) were assessed at baseline (t0), at 20 minutes (t1) and after 8 hours (t2) of wear. Fluorescein corneal and conjunctival staining and tear break up time (TBUT) were performed at t0 and t2. Results: No statistically significant changes were found between t0, t1 and t2 for TMA, and between t0 and t2 for fluorescein corneal and conjunctival staining. TBUT…
Effects of a nutraceutical formulation based on the combination of antioxidants and ω-3 essential fatty acids in the expression of inflamma…
2013
Maria D Pinazo-Durán,1,* Carmen Galbis-Estrada,1,* Sheila Pons-Vázquez,1 Jorge Cantú-Dibildox,2 Carla Marco-Ramírez,1 Javier Benítez-del-Castillo21Ophthalmic Research Unit Santiago Grisolia, Department of Surgery/Ophthalmology, Faculty of Medicine, University of Valencia, Valencia, Spain; 2Department of Ophthalmology, Hospital of Jerez, Jerez de la Frontera, Spain*These authors contributed equally to this workBackground: Women, and those older than 65 years of age, are particularly susceptible to dry eye disorders (DEDs). Inflammation is clearly involved in the pathogenesis of DEDs, and there is mounting evidence on the antioxidant and …
How Do Different Digital Displays Affect the Ocular Surface?
2020
Digital display use has been accepted as a contributing factor to dry eye disease. Nowadays, plenty of new models of digital displays have been developed, and the differences in their nature and the ways in which they are set and used may contribute to differences in the eye-related problems they cause.This study aimed to analyze the differences in ocular surface, tear film, and visual fatigue parameters after reading on different digital displays, with and without initial instillation of artificial tears.Thirty-one healthy individuals ranging in age from 20 to 26 years (mean ± standard deviation, 21.26 ± 1.73 years) were included in this prospective clinical study. Subjects' ocular surface…
A 12-month Prospective Study of Tear Osmolarity in Contact Lens Wearers Refitted with Daily Disposable Soft Contact Lenses
2020
SIGNIFICANCE Tear osmolarity has been reported as one of the best diagnostic tests for dry eye disease and its management. Contact lens wear is thought to influence tear homeostasis. Understanding how regular wear of contact lenses and their type affect tear osmolarity is important. PURPOSE The purpose of this study was to assess changes in tear osmolarity and ocular symptoms over a period of 12 months following refitting contact lens wearers with daily disposable contact lenses. METHODS Fifty subjects aged (mean ± SD) 26 ± 4 years were refitted with either silicone-hydrogel (delefilcon A, SiHy, n = 34) or hydrogel (omafilcon A, Hy, n = 16) daily disposable soft contact lenses. Study includ…
Assessment of corneal thickness and tear meniscus during contact-lens wear
2014
To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…
Meibomian glands structure in daily disposable soft contact lens wearers: a one‐year follow‐up study
2020
Purpose To assess the impact of daily disposable soft contact lenses on meibomian gland morphology over a period of 12 months. Methods Forty-one subjects (33 experienced and 8 neophytes) were fitted with either silicone-hydrogel or hydrogel daily contact lenses. The study protocol included four visits: baseline, day-2 for contact lens fit and follow-up measurements, as well as after 6 and 12 months of lens wear. Non-contact infrared meibography images were acquired with Keratograph 5M topographer (www.oculus.de) and analysed with an automated method, which objectively estimates the area of gland atrophy, gland length and width, number of glands and gland irregularity. Protocol at follow-up …
Ocular surface assessment in soft contact lens wearers; the contribution of tear osmolarity among other tests.
2014
: Purpose: To determine whether tear osmolarity contributes to the assessment of the ocular surface in soft contact lens (CL) wearers. Methods: Prospective, case–control series in 44 CL wearers (28 tolerant and 16 intolerant) and 34 healthy subjects. Every patient underwent a thorough ophthalmic examination with a tear osmolarity test (TearLab System), conjunctival impression cytology and meibomian lipid sampling. Symptoms, break-up time (BUT), tear osmolarity, conjunctival expression of HLA-DR and meibomian fatty acid composition were evaluated. Results: Tear osmolarity did not differ between controls and CL wearers (p = 0.23). Flow cytometry results expressed in antibody-binding capaci…
Assessment of induced corneal hypoxia in diabetic patients
2002
Comparative Study Address correspondence and reprint requests to Dr. C. Creuzot-Garcher, Service d'Ophtalmologie, CHU, Hopital Général, 3 Rue du Faubourg Raines, BP 1519, 21033 Dijon, France. E-mail: Catherine.creuzot-garcher@chu-dijon.fr; To assess the control of corneal hydration in patients with diabetes during a contact lens-induced hypoxia. Corneal stress was induced in 15 patients with diabetes and 23 healthy patients by having them wear contact lenses for 2 hours. Pachymetries were measured and corneal parameters (percentage recovery per hour [PRPH], time for deswelling [T99%] and induced swelling [IS]) were calculated. In the mean time, tears were collected to assess the activity of…