Search results for "Technetium"
showing 10 items of 42 documents
A simple method of bronchoprovocation using a valved holding chamber.
2004
This study was undertaken to ascertain whether the use of a valved holding chamber (VHC) during bronchial provocation testing might increase lung deposition and repeatability of the test relative to the tidal breathing method. The 2-min tidal breathing results were compared to five inhalations from a VHC device in patients using the Pari-provoII nebulizer (MMD = 2.1mkm). Lung and mouth deposition, losses though the exhaled air and losses before aerosol delivery to the patient's mouth were measured in patients using a radiolabeled 99Tc-DTPA solution and gamma camera. The study revealed that lung deposition was 67% with the VHC method, and losses with exhaled air were 29% of the inhaled amoun…
1937, Palermo: la scoperta del tecneto
2018
The Italian and international scenario of Physics and Chemistry in the thirties will be described, in order to introduce and better understand the successive steps that followed to the discovery of element 43 (Technetium). Of course, more emphasis will be given to the academic life in Palermo, where the discover took place: main characters and bit actors will be treated to give a full picture of the milieu. Finally, a glance will be given to the political events preceding and following the discover, and their consequences on people involved, as the possibility to realize in Palermo a multi disciplinary research team of high level, working on innovative arguments, was deeply compromised by t…
G.F.R. measuring with 99mTc-DTPA: limits in obstructive acute renal failure.
1991
After a short introduction on the advantages and limits of G.F.R. determination with Ccr, the radioisotopic methods proposed by Schlegel and Gates for this parameter are described, and as well as ERPF and FF, without blood serial samples being necessary. In a severe renal failure case due to obstruction, the Authors have found a great mismatch in the results between the traditional methods and the radioisotopic ones. After the clinical case description, a possible explanation of this discrepancy is proposed: Schlegel and Gates' methods, which well correlate Ccr in chronic renal failure cases, in severe renal failure on obstructive basis, of recent onset, could not indicate the effective glo…
Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children.
1995
Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm2 body surface) in addition to normal oral fluid intake, weight-related dose of99mTc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as “normal” with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinu…
Unusual case of continuous urinary dribbling in a young female due to unknown complex urogenital malformation: magnetic resonance features
2020
Congenital anomalies of kidney and urinary tract (CAKUT) occur in up to 3.2% of infants, and in almost one third of cases they are associated to genital aberrations. DMSA renal scintigraphy is considered the gold standard in CAKUT patients, to assess renal function, depict and locate ectopic kidney and to guide eventual surgical management. Recent cases have shown the noticeable limit of scintigraphy in detecting poorly functional renal moieties and associated genital anomalies; thus leading to a substantial delay in therapy, and, in females, to severe uro-gynecological complications. We herein describe a case of a young girl with unusual urinary dribbling, where DSMA scintigraphy was not d…
Experimental study of $^{100}$Tc $\beta$ decay with total absorption $\gamma$-ray spectroscopy
2017
International audience; The β decay of Tc100 has been studied by using the total absorption γ-ray spectroscopy technique at the Ion Guide Isotope Separator On-Line facility in Jyväskylä. In this work the new Decay Total Absorption γ-ray Spectrometer in coincidence with a cylindrical plastic β detector has been employed. The β intensity to the ground state obtained from the analysis is in good agreement with previous high-resolution measurements. However, differences in the feeding to the first-excited state as well as weak feeding to a new level at high excitation energy have been deduced from this experiment. Theoretical calculations performed in the quasiparticle random-phase approximatio…
Visualizing the atherosclerotic plaque: a chemical perspective.
2014
Atherosclerosis is the major underlying pathologic cause of coronary artery disease. An early detection of the disease can prevent clinical sequellae such as angina, myocardial infarction, and stroke. The different imaging techniques employed to visualize the atherosclerotic plaque provide information of diagnostic and prognostic value. Furthermore, the use of contrast agents helps to improve signal-to-noise ratio providing better images. For nuclear imaging techniques and optical imaging these agents are absolutely necessary. We report on the different contrast agents that have been used, are used or may be used in future in animals, humans, or excised tissues for the distinct imaging moda…
99mTechnetium-Mercaptoacetyltriglycin (MAG3) zum Nachweis von Nierenveränderungen nach extrakorporaler Stoßwellenlithotripsie
1992
Extracorporeal shock wave lithotripsy (ESWL) has become the treatment of choice for urinary calculi. 117 patients were studied prospectively with 99mTc mercaptoacetyltriglycine (MAG3) before and after ESWL. 79 (66%) of the 119 kidneys treated had abnormal findings. Of these 63/119 (53%) had abnormal scans. 41 (65%) had focal lesions with a delayed intrarenal transport. The remaining 22 had a diffuse delay of intrarenal transport. A loss of relative renal function of 3% and more compared to the pretreatment values was observed in 50/119 (42%) patients. 99mTc MAG3 should be done routinely together with radiologic tests (CT or MRI) before and after ESWL to select the patients at risk for post …
Re: Internal Jugular Vein and Cerebral Venous Sinus Infective Thrombophlebitis Detected With 99mTc-HMPAO White Blood Cell Scintigraphy.
2021
Laparoscopic sentinel lymph node mapping and excision of the rectum using a radioactive tracer — a prospective experimental study
2009
Introduction: Patients with a low risk T1 rectal carcinoma can undergo the therapy of a local excision. In these patients the lymph node status remains unknown. There is a potential risk of up to 7% for nodal metastasis, in high risk cases it can rise up to 35%. To investigate the possibility of using the Sentinel lymph node (SLN) concept, which is anchored in the therapy of malignant melanoma and breast cancer, an experimental study on pigs was undertaken. The objective of the study was to laparoscopically identify and extract SLN’s from the rectum using a radioactive tracer (RT). Material und Methods: The experiment was conducted upon 30 pigs, because sample size calculation indicated tha…