Search results for "Techniques"
showing 10 items of 4426 documents
Response to dopamine agonists of the rat isolated uterus.
1993
1. Quinpirole did not produce any effect in isolated uterus from oestrogenized rats even when it is contracted by KCl (37 mM). 2. Fenoldopam produced a relaxant effect on rat isolated uterus contracted by KCl which was not significantly modified by SCH 23390. 3. Reserpine decreased the effect of the lowest doses of fenoldopam. In reserpinized rats, propranolol (10(-9), 10(-8), 10(-7) M) antagonized the effect of the lowest doses of fenoldopam and neither SCH 23390, sulpiride nor ranitidine modified the effect of fenoldopam. 4. The results confirm our previous finding that DA1-receptors are not functional in our preparation. The effect of fenoldopam was partially due to a catecholamine-relea…
“The effectiveness of rapid antigen test-based for SARS-CoV-2 detection in nursing homes in Valencia, Spain”
2021
The usefulness of the PANBIOTM COVID-19 Ag rapid test for SARS-CoV-2 infection detection has not been widely studied, especially in specific population groups such as the elderly who are institutionalized. Rapid diagnostic tests have the potential to benefit testing strategies, as they have short turnaround times, they are cheap, simple to perform and can be used in decentralized testing. The objective of this study is to show the performance of the PANBIOTM COVID-19 Ag Rapid test device conducted at geriatric institutions and to compare results to those obtained from RT-PCR. A total of 448 individuals were enrolled in the study, including both residents and employees. Nasopharyngeal swabs …
Secretory effect of azodisalicylate (azodisal sodium) on the short circuited mucosa of the rat ileum in vitro.
1988
Azodisalicylate (ADS) is one of the newly developed substitutes of sulphasalazine consisting of two molecules of 5-amino-salicylic acid. Azodisalicylate caused diarrhoea in some patients, apparently caused by an antiabsorptive secretagogue action of this compound. The mechanism of this was studied in the short circuited isolated mucosa of the rat ileum. Mucosal addition of ADS increased the potential difference (PD) and short circuit current (Isc) at a concentration of 1.3.10(-4) mol/l (4 mg/dl) with maximal effects at 1.3.10(-3) mol/l (40 mg/dl). Epithelial resistance was only slightly decreased at the higher concentrations of 40 and 100 mg/dl. Serosal ADS had no effect on electrical param…
Model-specific effects of bumetanide on epileptiform activity in the in-vitro intact hippocampus of the newborn mouse.
2007
The immature brain has a higher susceptibility to develop seizures, which often respond poorly to classical pharmacological treatment. It has been recently suggested that bumetanide, which blocks Na(+)-dependent K(+)-Cl(-)-cotransporter isoform 1 (NKCC1) and thus attenuates depolarizing GABAergic responses, could soothe epileptiform activity in immature nervous systems. To evaluate whether bumetanide consistently attenuates epileptiform activity, we investigated the effect of 10 microM bumetanide in five different in-vitro epilepsy models using field potential recordings in the CA3 region of intact mouse hippocampal preparations at postnatal day 4-7. Bumetanide reduced amplitude and frequen…
Load progression criteria in exercise programmes in lower limb tendinopathy: a systematic review
2020
ObjectiveThe objective of this study is to summarise and analyse the current literature about what progression criteria are applied in loading exercise programmes in lower limb tendinopathies and their evidence and effectiveness.DesignSystematic review.MethodsPubMed, Embase, Scopus and PEDrowere searched from inception to 24 September 2020. The inclusion criteria were randomised controlled trials that included patients with midportion Achilles, patellar or gluteal tendinopathy; assessed function, pain or performance; included at least one group where progressive physical exercise was administered as monotherapy; included at least a control group. We excluded studies that included subjects w…
Measuring Intraoperative Oesophageal Anastomotic Tension With a Knot-Pusher–Mounted Dynamometer Is Not Quite Ready for Take-Off
2021
A Continuous Suture Anastomosis Outperforms a Simple Interrupted Suture Anastomosis in Esophageal Elongation.
2020
Abstract Introduction Long-gap esophageal atresia represents a distinct entity among the esophageal atresia spectrum. In many patients, achieving a reasonable anastomosis depends on some millimeters of tissue. We aimed to determine what effect the suturing technique would have on esophageal ex vivo elongation as it may determine the strength of a primary anastomosis. Materials and Methods In an analysis of porcine esophagi from animals for slaughter (100–120 days old with a weight of 100–120 kg), we determined esophageal length gain of simple continuous and simple interrupted suture anastomoses subjected to linear traction until linear breaking strength was reached. Statistical power of 80%…
In vitro comparison of platinum-iridium and gold tip electrodes: lesion depth in 4 mm, 8 mm, and irrigated-tip radiofrequency ablation catheters
2009
Aims We compared a newly developed irrigated gold tip electrode ablation catheter and a gold tip 4 and 8 mm catheter with the corresponding platinum–iridium (Pt) tip catheters in an in vitro setting. Methods and results In a flow chamber simulating physiological flow conditions, radiofrequency catheter ablation was performed on tissue samples of porcine endomyocardium and liver. Lesion depth, energy and temperature delivery, and popping frequency were determined. Two hundred and fifty-three ablations were conducted. Four and eight millimetre, gold tip electrode catheters produced significantly deeper lesions compared with the Pt tip electrode (liver 4 mm: 4.67 ± 1.7 vs. 2.9 ± 1.0 mm, P < 0.…
Accuracy of automatic airway morphometry in computed tomography-correlation of radiological-pathological findings.
2010
Abstract Objectives Airway morphology shows characteristic changes in different pathologies. This study assesses the accuracy of a current automatic airway assessment technique by correlating CT images of porcine airways to histological slices of the same localization. Materials and methods Four isolated and ventilated porcine lungs were frozen in a liquid nitrogen bath and examined with a CT scanner (MDCT). This technique both preserved normal radiomorphological appearance and made it possible to slice the specimens for histological examination for subsequent correlation. The parameters wall thickness (WT), wall percentage (WP), and total diameter (TD) were assessed by computer-aided measu…
Modulatory action of acetylcholine on cerebrovascular sympathetic neurotransmission
1991
1. Acetylcholine (10 micrograms/min) diminished the electrically-induced cerebral blood flow reductions. Atropine (1-2 mg) partially blocked this inhibitory effect. 2. Exogenously administered noradrenaline (1-10 micrograms) and tyramine (50-500 micrograms) reduced cerebral blood flow but this effect was unchanged by acetylcholine infusion. 3. Acetylcholine inhibited the nonadrenergic component of the electrically-induced contraction at a concentration greater than or equal to 10(-6) M and potentiated the adrenergic component at a concentration greater than or equal to 10(5) M. Atropine 10(-7) M) inhibited both of these effects. In addition, acetylcholine (10(-4) M) enhanced the electricall…