Search results for "Technology"
showing 10 items of 30343 documents
Residual Stress Effects on Fatigue Crack Growth in Ti-6Al-4V Friction Stir Welds
2008
Recent studies have illustrated a predominant role of the residual stress on the fatigue crack growth in friction stir welded joints. In this study, the role of the residual stress on the propagation of fatigue cracks orthogonal to the weld direction in a friction stir welded Ti-6Al-4V joint was investigated. A numerical prediction of the fatigue crack growth rate in the presence of the residual stresses was carried out using AFGROW software; reasonable correspondence between the predictions and the experimental results were observed when the effects of residual stress were included in the simulation.
Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach
2020
Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bo…
Traction test of temporary dental cements
2017
Background Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Material and methods Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear…
Quasi-Fractional Models of Human Tendons Hereditariness
2018
In this study, the authors, after collecting a series of experimental evidences following a creep and relaxation tendon campaign, propose a non-linear model of the viscoelastic behavior of the tendons. The ligaments investigated are the patellars and the hamstrings. The analytical model proposed by the authors aims to explain the non-linear hereditary behavior of these tissues and proposes an approach with which to develop a hereditary fractional-order non-linear model.
Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept
2020
Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsi…
Bio-silica and bio-polyphosphate: applications in biomedicine (bone formation)
2012
Bio-silica represents the main mineral component of the sponge skeletal elements (siliceous spicules), while bio-polyphosphate (bio-polyP), a multifunctional polymer existing in microorganisms and animals acts, among others, as reinforcement for pores in cell membranes. These natural inorganic bio-polymers, which can be readily prepared, either by recombinant enzymes (bio-silica and bio-polyP) or chemically (polyP), are promising materials/substances for the amelioration and/or treatment of human bone diseases and dysfunctions. It has been demonstrated that bio-silica causes in vitro a differential effect on the expression of the genes OPG and RANKL, encoding two mediators that control the …
Type V collagen counteracts osteo-differentiation of human mesenchymal stem cells
2014
In search of novel gene signatures for osteo-differentiation of mesenchymal stem cells (MSCs), we submitted cDNA preparations from undifferentiated and differentiating MSCs to differential display- and semiquantitative-PCR and found down-regulation of COL5A1 in osteo-induced cultures at days 21 and 28, when the mineralized matrix accumulates. We also cultured osteo-differentiating MSCs onto type V collagen substrates and found a decrease in the accumulation of extracellular calcium compared to those grown in uncoated flasks. To our knowledge, this is first evidence that type V collagen might represent a stromal component that impairs osteogenesis.
Bioactividad del polimetilmetacrilato (cemento óseo) modificado
1988
The polymethylmetacrylate bone cement reaction in clinical practice is conditioned in part by its biological activity and ageing An in vivo and in vitro experimental study was conducted to elucidate the possible implications of some bone cements mineral additives on bioactivity behaviour. ' Some substances (as quartz and wollastonite) can develop bioactivity phenomena when added to PMMA cement and may enhance its biological compatibility.
Ritz Solution for Transient Analysis of Variable-Stiffness Shell Structures
2020
The dynamic response of thin-walled structures is driven by mass and stiffness distribution. As such, variable-stiffness (VS) composites offer opportunities to tune structural dynamic responses. To this extent, efficient analysis tools become increasingly important for structural analysis and design purposes. In this work, an efficient and versatile Ritz method for free vibrations and linear transient analysis of VS doubly curved shell structures is presented. VS shell structures are modeled as an assembly of shell-like domains. The shell kinematics is based on the first-order shear deformation theory, and no further assumption is made on the shallowness or on the thinness of the structure.…
Stiffness and Reinforcement Effect of electrical Resistance Strain Gauges
2007
: The increasing use of low-modulus materials, on which the reinforcement effect of the electrical resistance strain gauge is not negligible, has re-opened the research interest into this issue. This study deals with the evaluation of stiffness, and of the strain gauge Young's modulus involved in the estimation of both the global and the local reinforcement effect; the relationship between the strain gauge stiffness and the local reinforcement effect is also analysed. In particular, the experimental technique used to determine the stiffness of some commercial strain gauges is described. The results show that the strain gauge stiffness alone does not permit an accurate evaluation of the loc…