Search results for "Temperature measurement"

showing 10 items of 123 documents

Emissivity measurements of several soils and vegetation types in the 8–14, μm Wave band: Analysis of two field methods

1997

Abstract The two variants of the box method (with one and two lids) has been rigorously analyzed. As a result of this analysis, a correction factor that takes into account the nonideality of the materials used for the box, as well as its geometry, has been derived A simple method for determining the effective downward atmospheric temperature that uses only the temperature measurement at the zenith also has been proposed. Finally, by using one of the two variants of the box method, 72 in situ emissivity measurements in the 8–14 pin wave-band region of typical vegetation, soils, and rocks of Europe and South America, has been obtained. The use of these data for the ernissivity correction of s…

Advanced very-high-resolution radiometerThematic MapperEmissivitySoil ScienceRadiometryGeologySatelliteComputers in Earth SciencesAtmospheric temperatureTemperature measurementGeologyZenithRemote sensingRemote Sensing of Environment
researchProduct

Study of Temperature Heterogeneities at Sub-Kilometric Scales and Influence on Surface–Atmosphere Energy Interactions

2019

The retrieval of land surface temperature (LST) from remote sensing techniques has been studied and validated during the past 40 years, leading to important improvements. Accurate LST values are currently obtained through measurements using medium resolution thermal infrared (TIR) sensors. However, the most recent review reports demonstrated that the future TIR LST products need to obtain reliable temperature values at a high spatial resolution (100 m or higher) to study temperature variations between different elements in a heterogeneous kilometric area. The launch of high-resolution TIR sensors in the near future requires studies of the temporal evolution and spatial heterogeneities of th…

Advection0211 other engineering and technologiesTerrain02 engineering and technologyTemperature measurementAtmosphereSea surface temperatureThermalGeneral Earth and Planetary SciencesEnvironmental scienceSatelliteElectrical and Electronic EngineeringImage resolution021101 geological & geomatics engineeringRemote sensingIEEE Transactions on Geoscience and Remote Sensing
researchProduct

A qualitative examination of performance and energy yield of photovoltaic modules in southern Norway

2010

Three different, commercially available photovoltaic modules have been monitored outdoors in the town of Grimstad, Norway. The present paper describes the experimental setup that was implemented, in particular details of the low-cost electronic loads. Results compare measured performance with manufacturer's data, and temperature measurements enable a comparison with performance at standard test condition temperature. Overall, the monocrystalline module performed best both regarding maximum efficiency and overall energy production, whereas the module based on triple junction amorphous silicon technology had the worst performance considering these criteria. The gross numbers of energy yield c…

Amorphous siliconEngineeringRenewable Energy Sustainability and the Environmentbusiness.industryPhotovoltaic systemElectrical engineeringSolar energyTemperature measurementAutomotive engineeringMonocrystalline siliconMaximum efficiencychemistry.chemical_compoundchemistryPerformance ratiobusinessEnergy (signal processing)Renewable Energy
researchProduct

Development of a test station for accurate in situ I-V curve measurements of photovoltaic modules in Southern Norway

2011

The development of an outdoor test station for accurate in situ I-V curve measurements of photovoltaic (PV) modules is described. The modules are installed in an open-rack configuration at the University of Agder in Southern Norway. Seven new and three aged PV modules of different type and make are being tested, including mono-and multicrystalline silicon from differing manufacturing routes, triple-junction amorphous silicon, and CIS. Data acquisition is controlled with a multichannel electronic load system and LabVIEW software, recording high-resolution I-V curves at one-minute intervals. Between I-V curve sweeps, each module is operated at the maximum power point. Characteristic electrica…

Amorphous siliconSiliconMaximum power principleVirtual instrumentationbusiness.industryPhotovoltaic systemElectrical engineeringchemistry.chemical_elementSolar irradianceTemperature measurementchemistry.chemical_compoundData acquisitionchemistryEnvironmental sciencebusiness2011 37th IEEE Photovoltaic Specialists Conference
researchProduct

A steady state and dynamic fuel cell model including temperature effects

2009

In the last few years fuel cells have attracted much interest from both academic and industrial researchers to replace current lithium-ion and similar rechargeable battery systems. A wide variety of research areas benefit from fuel cell use: electro-chemical, stationary, transportation and portable electronics can be cited as an example. Potential applications range from few watts to megawatts systems. Even concerning quite different scientific areas, fuel cell modelling is a common requirement. The complexity of such a topic relies not only on the modelling approach but also in the model structure and implementation. In this paper a steady state and dynamic fuel cell circuital model includ…

Battery (electricity)WattSteady state (electronics)Computer sciencefuel cell modellingRange (aeronautics)Proton exchange membrane fuel cellFuel cellsControl engineeringElectronicsTemperature measurement
researchProduct

Agreement between body surface and rectal temperature in cats

2021

Measuring body temperature in cats is an essential part of every clinical examination. Typically, rectal temperature measurement is conducted, but the procedure is poorly tolerated, and it often triggers stress-related changes in physiological parameters like pulse rate and blood pressure. Therefore, non-contact infrared thermometers have been studied on a few body surface measurement sites. However, existing studies included only commercial thermometers, which do not guarantee the correct temperature readings. In this study, we applied a custom-made and calibrated infrared thermometer for measuring feline body surface temperature on easily-accessible measurement sites of the eye, gum, and …

Body surface temperatureMean stressCATSMaterials scienceInfrared thermometerBlood pressurebusiness.industryBody surfaceRectal temperatureNuclear medicinebusinessTemperature measurementOptical Diagnostics and Sensing XXI: Toward Point-of-Care Diagnostics
researchProduct

Surface temperature in the context of FLuorescence EXplorer (FLEX) mission

2007

It has been demonstrated that the spectrum of fluorescence emission is dependent on leaf temperature, thus there is a need for thermal information in order to interpret fluorescence signals. Temperature is also related to transpiration and stomata closure, which affects CO2 uptake and fluorescence. Therefore temperature measurements help to confirm the trends observed in fluorescence measurements. While fluorescence is immediately and uniquely related to photosynthesis, temperature provides additional information about plant status and instantaneous energy/water fluxes between plants and the atmosphere. The objective of this paper is to demonstrate the role of surface temperature in the con…

BrightnessPlanetary boundary layerMeasuring instrumentEmissivityRadiometryContext (language use)Atmospheric temperatureTemperature measurementRemote sensing2007 IEEE International Geoscience and Remote Sensing Symposium
researchProduct

CARS spectroscopy of CH4 for implication of temperature measurements in supercritical LOX/CH4 combustion

2007

International audience; Experimental and theoretical investigations of coherent anti-Stokes Raman spectroscopy of CH4 have been carried out. Experimental spectra were measured in a heated high-pressure test cell and compared with numerical simulations. Good agreement was obtained for the temperature and the pressure dependence of CARS spectra in the ranges 300-1100 K and 0.1-5.0 MPa. The observed dependencies provide useful guidance for CARS thermometry, allowing quantitative measurements of temperature in high-pressure combustors. Application of multiplex CH4 CARS thermometry for single-shot measurements in a LOX/CH4 combustion at high pressure was demonstrated at supercritical conditions …

CH4 spectroscopyMaterials scienceAnalytical chemistryAerospace EngineeringCombustion01 natural sciences7. Clean energyTemperature measurementSpectral lineMethane010305 fluids & plasmas010309 opticssymbols.namesakechemistry.chemical_compoundNuclear magnetic resonancesupercritical pressure0103 physical sciencesLOX/CH4 combustionSpectroscopy[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics][ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]temperatureSupercritical fluidchemistrysymbolscoherent anti-Stokes Raman scatteringLiquid oxygenRaman spectroscopyAerospace Science and Technology
researchProduct

Temperature measurement in gas mixtures by femtosecond Raman-induced polarization spectroscopy

2003

The potential of femtosecond Raman-induced polarization spectroscopy (RIPS) for the simultaneous determination of temperature and concentrations was investigated. These measurements were related to the rotational time response of the molecular gas mixture, which was measured as a function of the pump-probe time delay. The change of the polarizability anisotropy with respect to the vibrational levels was taken into account. The results of temperature measurements in pure CO2 showed good agreement with the values obtained by a thermocouple. The RIPS technique was also applied to a CO2-N2 gas mixture to determine simultaneously temperatures and concentrations at temperatures up to 600 K. The a…

ChemistryAnalytical chemistryInduced polarizationTemperature measurementsymbols.namesakeThermocouplePolarizabilityFemtosecondsymbolsGeneral Materials ScienceAnisotropyRaman spectroscopySpectroscopySpectroscopyJournal of Raman Spectroscopy
researchProduct

Temperature imaging and image processing in the steel industry

1996

Our aim is twofold: to present our temperature measurement system based on CCD technology, which gives a linear response versus temperature, and to display two industrial applications in which our system has been involved to optimize and characterize the process. We present a short summary dealing with temperature evaluations from radiation measurements. We consider especially the problems of the surroundings, the atmosphere, and the emissivity assumption. After selecting a value for the emissivity, we show that the use of the CCD technology enables us to obtain high spatial and temporal resolution temperature imaging, and provides further information, mainly a linear response versus temper…

Cladding (metalworking)Computer sciencebusiness.industryGeneral EngineeringImage processingRadiationTemperature measurementAtomic and Molecular Physics and OpticsAtmosphereTemporal resolutionEmissivityProcess controlProcess engineeringbusinessOptical filterImage resolutionSimulationOptical Engineering
researchProduct