Search results for "Testing"
showing 10 items of 1769 documents
Mechanical behavior of provisional implant prosthetic abutments
2014
Introduction: Implant-supported prostheses have to overcome a major difficulty presented by the morphology and esthetics of peri-implant tissues in the anterior sector. Diverse therapeutic techniques are used for managing the mucosa adjacent to the implant and the most noteworthy is immediate/deferred fixed provisionalization. Objectives: In vitro testing of strength and deformation of implant prosthetic abutments made from different materials (Titanium/PEEK/methacrylate). Material and Methods: Forty Sweden&Martina® implant prosthetic abutments (n=40) were divided into five groups: Group MP: methacrylate provisional abutments with machined titanium base; Group PP: Poly ether ether ketone (P…
Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.
2013
Abstract Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the s…
Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study
2007
Determination of cortical bone thickness is warranted, e.g., for assessing the level of endosteal resorption in osteoporosis or other bone pathologies. We have shown previously that the velocity of the fundamental antisymmetric (or flexural) guided wave, measured for bone phantoms and bones in vitro, correlates with the cortical thickness significantly better than those by other axial ultrasound methods. In addition, we have introduced an inversion scheme based on guided wave theory, group velocity filtering and 2-D fast Fourier transform, for determination of cortical thickness from the measured velocity of guided waves. In this study, the method was validated for tubular structures by usi…
Determination of Bubble Size Distribution Using Ultrasound Array Imaging
2020
In this article, ultrasonic phased arrays are deployed as an imaging tool for industrial process analysis. Such arrays are typically used for sonar, medical diagnosis, and nondestructive testing; however, they have not yet been applied to industrial process analysis. The precise positioning of array elements and high frequencies possible with this technology mean that highly focused images can be generated, which cannot currently be achieved using ultrasound tomography. This article aims to highlight the potential of this technology for the measurement of bubble size distribution (BSD) and to demonstrate its application to both intrusive and noninvasive process measurements. Ultrasound imag…
Laser ultrasonics for defect evaluation on coated railway axles
2020
Abstract This scientific paper focuses on the application of an advanced non-destructive technique for an effective inspection of railway axles. The method pertains to ultrasonic techniques, which are widely used in the railway field. The experimental investigation was carried out on simulated defects tooled near the cross section reduction of the axle, in order to simulate fatigue cracks which, due to notch effect, can trigger crack propagation and axle failure. The aim of this research activity is to evaluate how efficiently the proposed technique detects defects and to verify its applicability to axles with a black coating for protection. In view of the experimental setup, comprising a p…
Comparison of spring characteristics of titanium-molybdenum alloy and stainless steel
2017
Background Titanium-molybdenum alloy (TMA) and stainless steel (SS) wires are commonly used in orthodontics as arch-wires for tooth movement. However, plastic deformation phenomenon in these arch-wires seems to be a major concern among orthodontists. This study aimed to compare the mechanical properties of TMA and SS wires with different dimensions. Material and Methods Seventy-two wire samples (36 TMA and 36 SS) of three different sizes (19×25, 17×25 and 16×22) were analyzed in vitro, with 12 samples in each group. Various mechanical properties of the wires, including spring-back, bending moment and stiffness were determined using a universal testing machine. Student’s t-test showed statis…
Effect of alloy type and casting technique on the fracture strength of implant-cemented structures.
2010
Objectives: To evaluate the influence of alloy type and casting procedure on the fracture strength (FS) of metallic frameworks for implant-supported fixed prostheses. Study design: Thirty three-unit structures for lower posterior bridges were waxed-up and randomly assigned to two groups (n=15) according to alloy type and casting technique: Group 1 (C): cobalt-chromium cast in a centrifugal machine (TS1, Degussa-Hüls); Group 2 (T): titanium cast in a pressure-differential device (Cyclarc II, Morita). Each structure was cemented onto two prefabricated abutments under a constant seating pressure. After 6 months of water aging, samples were loaded in a static universal testing machine (EFH/5/FR…
Outgrowth endothelial cells isolated and expanded from human peripheral blood progenitor cells as a potential source of autologous cells for endothel…
2006
One challenge of particular importance in tissue engineering is to improve vascularization of larger size defects, which would then facilitate a sufficient supply with oxygen and nutrients to the central regions of a larger tissue-engineered construct or in highly vascularized tissues. In this study, we show that outgrowth endothelial cells (OECs) derived from human peripheral blood can serve as a source of human autologous endothelial cells and can be used in combination with fibroin silk fiber meshes for applications in tissue engineering. OEC reveal a highly differentiated endothelial phenotype as well as a high phenotypic stability during their expansion. Furthermore, OEC showed very pr…
Tissue-like self-assembly in cocultures of endothelial cells and osteoblasts and the formation of microcapillary-like structures on three-dimensional…
2007
The survival and functioning of a bone biomaterial requires a rapid and stable vascularization after implantation. However, the mechanisms involved in the context of the complex healing microenvironment are poorly understood. To evaluate the vascularization potential of bone biomaterials, angiogenic stimuli were added to human dermal microvascular endothelial cells (HDMEC) growing on three-dimensional (3-D) bone biomaterials consisting of porous hydroxyapatite, porous calcium phosphate, porous nickel-titanium, successfully being used in humans, and also silk fibroin nets. HDMEC did not migrate to form microcapillary-like structures as they did on cell culture plastic. In cocultures of HDMEC…
Endothelialization of a non-woven silk fibroin net for use in tissue engineering: growth and gene regulation of human endothelial cells
2004
Abstract We have previously shown that a biomaterial consisting of a non-woven fibroin net produced from silk (Bombyx mori) cocoons is an excellent scaffolding material for a wide variety of human cells of different tissue types. Endothelialization must take place for a biomaterial to be successful after implantation. Therefore, primary human endothelial cells and the human endothelial cell lines, HPMEC-ST1.6R and ISO-HAS-1, were examined for adherence and growth patterns on the fibroin nets by confocal laser scanning microscopy after vital staining of the cells and by electron microscopy. Endothelial cells adhered and spread along individual fibers of the nets and did not fill the gaps bet…