Search results for "Thermistor"
showing 6 items of 6 documents
Steam sterilization processes affect the stability of clinical thermometers: Thermistor and prototypal FBG probe comparison
2020
Abstract Temperature is one of the most frequently measured physical quantities in clinical environment and a good biomarker of illness. The need for reusable probes, which have to be sterilized to prevent infections, requires the metrological qualification of thermometer probes in response to ageing effects induced by several sterilization processes. In this study, we investigated the effect of repeated sterilizations on both a commonly-used autoclavable thermistor probe and a prototypal Fiber Bragg Gratings (FBG) probe for temperature measurements. Findings highlighted a greater reliability of the proposed FBG probe than the commercial thermistor. Specifically, the FBG probe was able to w…
Electric and elastic properties of conductive polymeric nanocomposites on macro- and nanoscales
2002
Abstract In the past several years, the macroscopic electric and elastic properties of conductive polymeric composites have been studied from the viewpoint of such applications as thermistors and pressure sensors. In particular, we studied carbon black (CB) polymeric nanocomposites on macro- and nanoscales, using polyisoprene as the composite matrix. The filler component was an extra conductive carbon black (PRINTEX XE2, DEGUSSA) with a primary particle diameter of about 30 nm. A very strong reversible tensoresistive effect of electric resistance dependence on uniaxial tension deformation was observed in composites with the 10 carbon black mass parts added to 100 mass parts of polyisoprene.…
Difference temperature-to-time electronic interface based on a thermistor-to-generalized impedance converter
2010
Abstract In this work a difference temperature-to-time converter is shown using two thermistors working in a DC generalized impedance converter. Voltage drop in one of the thermistors depends on the temperature difference between them. This voltage is compared with a time varying exponential reference voltage obtaining a time interval at the output circuit with good linear dependence with respect to the input temperature difference. Experimental results are obtained showing a new generalized impedance converter application. The implemented circuit was characterized by a repeatability of 1.0%, a reproducibility of 4.5% and a relative accuracy of 1.3%.
The constellation-X focal plane microcalorimeter array: An NTD-germanium solution
2002
The hallmarks of Neutron Transmutation Doped (NTD) germanium cryogenic thermistors include high reliability, reproducibility, and long term stability of bulk carrier transport properties. Using micro-machined NTD Ge thermistors with integral “flying” leads, we can now fabricate two-dimensional arrays that are built up from a series of stacked linear arrays. We believe that this modular approach of building, assembling, and perhaps replacing individual modules of detectors is essential to the successful fabrication and testing of large multi-element spectrometers. Details of construction are presented.
Spectral broadening by spatial effects in X-ray microcalorimeters with superconducting absorber and NTD-Ge thermal sensor
2004
We discuss how the sensitivity to the position of absorption of the photons can affect the spectral resolution of X-ray microcalorimeters with superconducting Sn absorber and NTD-Ge thermal sensor. Data obtained through the computer simulations are reported for microcalorimeters with different geometries and phonon transmission probabilities at the interface between the absorber and thermistor.
A fully planar approach to the construction of X-Ray microcalorimeters with doped Germanium sensors
2008
We have investigated a fully planar technology for the development of arrays of X-ray microcalorimeters with doped germanium thermal sensor. We describe the proposed approach and show promising results obtained with the deep etching of germanium, the most critical step of the whole process.