Search results for "Thermodynamics"

showing 10 items of 2774 documents

Thermodiffusion motion of electrically charged nanoparticles

2012

AbstractThe present work deals with experimental studies to examine the theoretical model of thermodiffusion of electrically charged nanoparticles. Three different ionic magnetic colloid samples have been synthesized and profoundly analyzed. The theoretical model is a classical one, based on the calculation of the temperature and the electric potential distribution around nanoparticles. The discrepancy between experimental data and theory turns out not to exceed 20%. We focus on applying different approximations between calculated electrical double layer in the theoretical model and experimental determination of the surface charge density of colloidal particles. We assume this is the main r…

magnetic colloidsWork (thermodynamics)Materials scienceCondensed matter physicssoret coefficientPhysicsQC1-999General Physics and AstronomyIonic bondingMagnetic colloidNanoparticleMotion (geometry)Charge densityelectrically charged nanoparticlesClassical mechanicsColloidal particletermodiffusionElectric potentialOpen Physics
researchProduct

Geometric Aspects of Thermodynamics

2016

This chapter deals with mathematical aspects of thermodynamics most of which will be seen to be primarily of geometrical nature. Starting with a short excursion to differentiable manifolds we summarize the properties of functions, of vector fields and of one-forms on thermodynamic manifolds. This summary centers on exterior forms over Euclidean spaces and the corresponding differential calculus. In particular, one-forms provide useful tools for the analysis of thermodynamics. A theorem by Caratheodory is developed which is closely related to the second law of thermodynamics. The chapter closes with a discussion of systems which depend on two variables and for which there is an interesting a…

media_common.quotation_subjectEuclidean geometryExterior derivativeThermodynamicsDifferential calculusVector fieldSecond law of thermodynamicsCanonical transformationTangent vectorDirectional derivativeMathematicsmedia_common
researchProduct

Analysis of a viscoelastic phase separation model

2020

A new model for viscoelastic phase separation is proposed, based on a systematically derived conservative two-fluid model. Dissipative effects are included by phenomenological viscoelastic terms. By construction, the model is consistent with the second law of thermodynamics, and we study well-posedness of the model, i.e., existence of weak solutions, a weak-strong uniqueness principle, and stability with respect to perturbations, which are proven by means of relative energy estimates. A good qualitative agreement with mesoscopic simulations is observed in numerical tests.

media_common.quotation_subjectFOS: Physical sciencesSecond law of thermodynamics02 engineering and technologySpace (mathematics)01 natural sciencesStability (probability)ViscoelasticityMathematics - Analysis of PDEs0103 physical sciencesFOS: MathematicsGeneral Materials ScienceStatistical physicsUniqueness010306 general physicsMathematical Physicsmedia_commonPhysicsMesoscopic physicsDynamic structure factorMathematical Physics (math-ph)021001 nanoscience & nanotechnologyCondensed Matter PhysicsDissipative system0210 nano-technologyAnalysis of PDEs (math.AP)
researchProduct

Identical fits of nonnegative matrix/tensor factorization may correspond to different extracted event-related potentials

2010

Nonnegative Matrix / Tensor factorization (NMF/NTF) have been used in the study of EEG, and the fit (explained variation) is often used to evaluate the performance of a nonnegative decomposition algorithm. However, this parameter only reveals the information derived from the mathematical model and just exhibits the reliability of the algorithms, and the property of EEG can not be reflected. If fits of two algorithms are identical, it is necessary to examine whether the desired components extracted by them are identical too. In order to verify this doubt, we performed NMF and NTF on the same dataset of an auditory event-related potentials (ERPs), and found that the identical fits of NMF and …

medicine.diagnostic_testComponent (thermodynamics)Property (programming)business.industryFeature extractionPattern recognitionElectroencephalographyMatrix decompositionNon-negative matrix factorizationTime–frequency analysismedicineArtificial intelligenceNonnegative matrixbusinessMathematicsThe 2010 International Joint Conference on Neural Networks (IJCNN)
researchProduct

Fast Isolation by AFLP of Sequences Containing Repeats

2013

Fast isolation by AFLP of sequences containing repeats (FIASCO) is a rapid and simple method for separating microsatellite-containing DNA fragments from genomic DNA de novo. The method takes the advantage of the amplified fragment length polymorphism (AFLP) technique that relies on effective digestion-ligation reaction. The repeat-containing fragments are selectively hybridized to biotinylated probes and harvested by streptavidin-coated magnetic beads. The enriched microsatellite-containing fragments can be cloned and sequenced to yield a variety of microsatellite loci for applications in many different fields in molecular genetics.

medicine.medical_specialtyAmplified Fragment Length Polymorphism AnalysisComputational biologyBiologygenomic DNAchemistry.chemical_compoundNucleic acid thermodynamicschemistryMolecular geneticsmedicineDirect repeatMicrosatelliteAmplified fragment length polymorphismDNA
researchProduct

Assessment of the cardiostimulant action of propionyl-L-carnitine on chronically volume-overloaded rat hearts.

1993

Chronic volume overload was induced in young rats of Wistar strain by surgical opening of the aorto-caval fistula. Three months later, during in vitro perfusion with exogenous palmitate, left ventricular function and energy turnover (QO2) of hypertrophied hearts were severely depressed. This seemed to be related to impaired long-chain fatty acid utilization, as reflected by decreased 14CO2 production from U-14C-palmitate and decreased tissue levels of L-carnitine. Another group of rats exposed to chronic volume overload was pretreated for 2 weeks before sacrifice with propionyl-L-carnitine (250 mg/kg/day), and the hearts were perfused with 1.2 mM palmitate and 10 mM propionyl-L-carnitine. I…

medicine.medical_specialtyCardiotonic AgentsVolume overloadPalmitatesCardiomegalyMitochondria HeartVentricular Function LeftMuscle hypertrophyContractilityOxygen ConsumptionInternal medicineCarnitinemedicineAnimalsPharmacology (medical)Rats WistarPharmacologychemistry.chemical_classificationVentricular functionbusiness.industryMyocardiumFatty acidGeneral MedicinePropionyl l carnitineCarbon DioxideMyocardial ContractionRatsEndocrinologychemistryVolume (thermodynamics)Cardiac hypertrophyCardiology and Cardiovascular MedicinebusinessCardiovascular drugs and therapy
researchProduct

Indirect estimation of stomach volume of rainbow trout Oncorhynchus mykiss (Walbaum)

2005

The main hypothesis of this study was that if stomach volume is correlated with food intake it can be estimated without laborious and destructive direct measurement. Rainbow trout, Oncorhynchus mykiss (Walbaum), ca. 500^1300 g, were starved for 1, 4, 8 or16 days at151C after which they were fed in excess with dry pellets containing known amounts of X-raydense markers. Immediately after feeding the ¢sh were killed, X rayed and weighed. Then the stomach was dissected, its contents removed and weighed, and stomach volume was measured. X-ray plates were developed and feed intake was estimated based on the amount of marker. All measured variables correlated positively with stomach volume. The be…

medicine.medical_specialtyFood intakeStomachdigestive oral and skin physiologyAquatic ScienceBiologyEndocrinologyAnimal sciencemedicine.anatomical_structureDry weightVolume (thermodynamics)Internal medicinemedicineRainbow troutAquaculture Research
researchProduct

Resistance Training with Single vs. Multi-joint Exercises at Equal Total Load Volume: Effects on Body Composition, Cardiorespiratory Fitness, and Mus…

2017

The present study aimed to compare the effects of equal-volume resistance training performed with single-joint (SJ) or multi-joint exercises (MJ) on VO2max, muscle strength and body composition in physically active males. Thirty-six participants were divided in two groups: SJ group (n = 18, 182.1 ± 5.2, 80.03 ± 2.78 kg, 23.5 ± 2.7 years) exercised with only SJ exercises (e.g., dumbbell fly, knee extension, etc.) and MJ group (n = 18, 185.3 ± 3.6 cm, 80.69 ± 2.98 kg, 25.5 ± 3.8 years) with only MJ exercises (e.g., bench press, squat, etc.). The total work volume (repetitions × sets × load) was equated between groups. Training was performed three times a week for 8 weeks. Before and after the…

medicine.medical_specialtyPhysiologySquatAerobic capacity; Fat loss; Muscle strength; Resistance exercise; Strength training; Physiology; Physiology (medical)Bench presslcsh:Physiology03 medical and health sciences0302 clinical medicinePhysiology (medical)strength trainingMedicinefat lossOriginal ResearchAerobic capacity Fat loss Muscle strength Resistance exercise Strength trainingSettore M-EDF/02 - Metodi E Didattiche Delle Attivita' Sportivelcsh:QP1-981Multi jointbusiness.industryResistance trainingVO2 maxCardiorespiratory fitness030229 sport sciencesaerobic capacityresistance exerciseVolume (thermodynamics)Muscle strengthPhysical therapymuscle strengthbusinessSettore M-EDF/01 - Metodi E Didattiche Delle Attivita' Motoriehuman activities030217 neurology & neurosurgeryFrontiers in physiology
researchProduct

Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik

2005

Purpose To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. Materials and methods Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using …

medicine.medical_specialtyShort axisVentricular functionmedicine.diagnostic_testbusiness.industryPhase contrast microscopySignificant differenceMagnetic resonance imagingBlood flowlaw.inventionSurgeryVolume (thermodynamics)Flow (mathematics)Paired sampleslawmedicine.arteryAscending aortaLeft ventricular Stroke volumeMedicineRadiology Nuclear Medicine and imagingSystolebusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Blood Volume Substitutes in Emergency Care

1985

Volume substitutes for restoring circulating blood volume are eminently important for emergency care. In addition to side effects, the intravascular volume effect immediately after infusion and the duration of this volume effect are determining factors for the selection of volume replacement solutions available on the market today. Therefore, we controlled the intravascular volume effect of 16 test solutions, immediately as well as 90 and 240 min after the end of infusion.

medicine.medical_specialtyVolume (thermodynamics)Volume effectbusiness.industryAnesthesiaVolume replacementEmergency medicineEmergency MedicineIntravascular volume statusMedicineBlood volumeEmergency NursingbusinessPrehospital and Disaster Medicine
researchProduct