Search results for "Thermometer"
showing 10 items of 48 documents
Metal thin-film temperature sensor embedded in heat-sink for CPV cells characterization
2014
The efficiency of a photovoltaic cell is dependent on its temperature, for this reason an accurate measurement of this parameter is important to fully characterize the device and to optimize its performance. For CPV applications a significant heat flux is needed to remove excess heat from the cell towards a heat sink, making it difficult to derive the cell temperature. In fact, measurements performed directly between the cell and the heat-sink, by use of commercial bulk sensors, would produce a significant disturbance in the heat flow; on the other hand, a measurement performed out of the cell / heat sink axis would be subject to large uncertainties, due to the high radial temperature gradi…
A Luminescent Thermometer Exhibiting Slow Relaxation of the Magnetization: Toward Self-Monitored Building Blocks for Next-Generation Optomagnetic Dev…
2019
The development and integration of Single-Molecule Magnets (SMMs) into molecular electronic devices continue to be an exciting challenge. In such potential devices, heat generation due to the electric current is a critical issue that has to be considered upon device fabrication. To read out accurately the temperature at the submicrometer spatial range, new multifunctional SMMs need to be developed. Herein, we present the first self-calibrated molecular thermometer with SMM properties, which provides an elegant avenue to address these issues. The employment of 2,2′-bipyrimidine and 1,1,1-trifluoroacetylacetonate ligands results in a dinuclear compound, [Dy2(bpm)(tfaa)6], which exhibits slow …
System B, Endo-Twinn and E-Fill. True temperatures inside the canal
2012
Background: The aim of this study is to verify the variations of the temperature inside the root canal with three different gutta-percha heating systems. Materials and Methods: A split-tooth model was built with a lateral groove at 3.5-mm from working length (WL) in order to insert a Chromel-Alumel K-type thermocouple placed in contact with gutta-percha. The thermocouple was connected to a digital thermometer. Sixty obturations were made with medium gutta-percha points. For 20 specimens the System B was used with the Buchanan fine plugger and the temperature was set at 200°C; for other 20 specimens the Endo-Twinn with a fine plugger was used and for the last 20 specimens we used the E-Fill …
Niobium Nitride Thin Films for Very Low Temperature Resistive Thermometry
2019
We investigate thin film resistive thermometry based on metal-to-insulator-transition (niobium nitride) materials down to very low temperature. The variation of the NbN thermometer resistance have been calibrated versus temperature and magnetic field. High sensitivity in tempertaure variation detection is demonstrated through efficient temperature coefficient of resistance. The nitrogen content of the niobium nitride thin films can be tuned to adjust the optimal working temperature range. In the present experiment, we show the versatility of the NbN thin film technology through applications in very different low temperature use-cases. We demonstrate that thin film resistive thermometry can …
Control of brain temperature during experimental global ischemia in rats.
1999
Temperature control during experimental ischemia continues to be of major interest. However, if exposure of brain tissue is necessary during the experiment, regional heat loss may occur even when the core temperature is maintained. Furthermore, valid non-invasive brain temperature monitoring is difficult in small rodents. This paper describes a method for both monitoring and maintenance of brain temperature during small animal preparations in a stereotaxic frame. The device used includes an ear-bar thermocouple probe and a small near-infrared radiator. The new equipment permitted to maintain peri-ischemic brain temperature at a desired level while carrying out non-invasive continuous record…
Precisión diagnóstica del termómetro de distrés en neoplasias hematológicas
2016
Objective: The present study extends the previous investigation about validity and diagnostic accuracy of the DT for detecting psychosocial distress among Spanish cancer patients. The Distress Thermometer (DT) is a common screening tool, but other methods –such as Impact Thermometer (IT)- have recently been proposed with the aim of improving its diagnostic accuracy. In this paper, we investigated the emotional symptomatology captured by the DT, and the diagnostic accuracy of both the DT alone and combined with the IT, using two possible combination methods. Methods: A sample of 81 adult patients with hematologic cancer completed the DT, the Colored Complaint Scale (CCS), the IT and the Brie…
Feasibility of Coulomb blockade thermometry in metrology
2000
Abstract Coulomb blockade thermometer (CBT) is a simple, magnetic-field-independent primary thermometer for everyday use at cryogenic temperatures. Its properties are well understood by now. The absolute accuracy at present is about ±0.5%. Recently, we have started studying the possibility of using CBT in metrological applications. We have especially in mind the future extension of the international temperature scale below 0.65 K, which is the lower end of ITS-90. Experiments with arrays containing more than 100 tunnel junctions in series are in progress in order to decrease the effects of electromagnetic environment and of co-tunnelling even below the present level.
Noise analysis for calorimetric low-temperature detectors for heavy ions
2004
The energy resolution of calorimetric low-temperature detectors for heavy ions has been analyzed. It is shown that the contribution of base line noise is small. The energy resolution is determined by intrinsic fluctuations of the detector signal. An incomplete energy thermalization during the stopping process of the heavy ion, the dependence of signal shape on impact position and fluctuations of the Al-TES thermometer response are considered as main sources of detector line broadening. Test measurements with 5 MeV α-particles are presented.
One and two dimensional tunnel junction arrays in weak Coulomb blockade regime-absolute accuracy in thermometry
1999
We have investigated one and two dimensional (1D and 2D) arrays of tunnel junctions in partial Coulomb blockade regime. The absolute accuracy of the Coulomb blockade thermometer is influenced by the external impedance of the array, which is not the same in the different topologies of 1D and 2D arrays. We demonstrate, both by experiment and by theoretical calculations in simple geometries, that the 1D structures are better in this respect. Yet in both 1D and 2D, the influence of the environment can be made arbitrarily small by making the array sufficiently large.
Sub-kelvin current amplifier using DC-SQUID
2000
Abstract We have set up a system where a low-noise DC-SQUID is used as a current amplifier. The SQUID output is read using a wide band electronics unit based on the noise cancellation scheme. The SQUID has been installed in a compact Nanoway PDR50 dilution refrigerator, and superconducting transitions of Ti/Au thermometer strips for X-ray calorimeter applications have been measured. We can operate at 100 mK using a SQUID with Pd shunt resistors. Noise and bandwidth results of the setup are presented.