Search results for "Tibial Fracture"
showing 10 items of 23 documents
Can Clinical and Surgical Parameters Be Combined to Predict How Long It Will Take a Tibia Fracture to Heal? A Prospective Multicentre Observational S…
2018
Background. Healing of tibia fractures occurs over a wide time range of months, with a number of risk factors contributing to prolonged healing. In this prospective, multicentre, observational study, we investigated the capability of FRACTING (tibia FRACTure prediction healING days) score, calculated soon after tibia fracture treatment, to predict healing time.Methods. The study included 363 patients. Information on patient health, fracture morphology, and surgical treatment adopted were combined to calculate the FRACTING score. Fractures were considered healed when the patient was able to fully weight-bear without pain.Results. 319 fractures (88%) healed within 12 months from treatment. Fo…
Leg ulcer and osteomyelitis due to methicillin-susceptible Staphylococcus aureus infection after fracture repair treatment: a case highlighting the p…
2015
Prostaglandins appear to reduce biofilm formation and chronicization of infections, and stimulate a rapid and effective clearance of infecting micro-organisms. We report a case of recovery from methicillin-susceptible Staphylococcus aureus (MSSA) osteomyelitis after multidisciplinary management with antibiotics, anti-thrombotics and prostaglandin E1 (PGE1) vasodilator, in a patient with tibial plateau fracture repaired with internal fixation devices. A 47-year-old HIV-negative male with chronic ulcer on the proximal third of the left leg was admitted to the Orthopaedic Unit of the Orestano Clinic in Palermo, Italy, for suspected osteomyelitis. A biopsy of the skin ulcer and blood cultures w…
Augmentation of tibial plateau fractures with an injectable bone substitute: CERAMENT™. Three year follow-up from a prospective study
2015
Background: Reduction of tibial plateau fractures and maintain a level of well aligned congruent joint is key to a satisfactory clinical outcome and is important for the return to pre-trauma level of activity. Stable internal fixation support early mobility and weight bearing. The augmentation with bone graft substitute is often required to support the fixation to mantain reduction. For these reasons there has been development of novel bone graft substitutes for trauma applications and in particular synthetic materials based on calcium phosphates and/or apatite combined with calcium sulfates. Injectable bone substitutes can optimize the filling of irregular bone defects. The purpose of this…
Effect of previous exercise on fracture healing: a biochemical study with mice.
1974
(1974). Effect of Previous Exercise on Fracture Healing: A Biochemical Study with Mice. Acta Orthopaedica Scandinavica: Vol. 45, No. 1-4, pp. 481-489.
Assessment of Lower Limb Load Distribution in Patients Treated with the Ilizarov Method for Tibial Nonunion
2021
BACKGROUND Successful treatment of tibial nonunion should lead to a complete bone union, lack of pain, and pathological mobility of the lower extremity, as well as to the achievement of satisfactory joint mobility and muscle strength, which in turn improves its biomechanics. The objective of this study was to assess the load placed on the lower limbs in patients subjected to treatment with the Ilizarov method due to aseptic tibial nonunion. MATERIAL AND METHODS This research involved 24 participants (average age, 55 years). All were diagnosed with aseptic tibia nonunion and treated with the Ilizarov external fixator between 2000 and 2017. The control group was matched to the treated group i…
Secondary Osseous Integration of Cementless Unicompartmental Knee Arthroplasty After Internal Fixation of a Felix Type IIIB Fracture
2021
Case A 76-year-old man presented with periprosthetic tibial plateau fracture (TPF), with a completely loosened tibial component 3 weeks after cementless unicompartmental knee arthroplasty (UKA). Internal fixation by buttress plating was performed, and the tibial component was retained and left in situ primarily as a spacer. Revision was planned after fracture consolidation, but at 3 months, the patient was able to walk without support, without pain, and with full range of motion. At 1 year, he is free of complaints. The initial loosened tibial component reintegrated. Conclusion Internal fixation combined with preserving the loosened tibial component may be a treatment option for TPF involvi…
Valoración funcional en pacientes intervenidos mediante plastia de LCA con semitendinoso-recto interno y sistema Togglelock.
2020
espanolIntroduccion: Una de las lesiones mas frecuente de la rodilla y que esta en aumento, sobre todo en el ambito deportivo es la lesion del ligamento cruzado anterior. La reconstruccion quirurgica es fundamental para recuperar la biomecanica de la rodilla, proporcionar una correcta estabilidad y funcionamiento libre de dolor, asi como evitar cambios degenerativos tempranos. El objetivo del presente estudio fue valorar la recuperacion funcional de los pacientes sometidos a una reconstruccion del ligamento cruzado anterior mediante ligamentoplastia con tendon semitendinoso-recto interno y sistema Toggelock. Material y metodos: Se diseno un estudio retrospectivo descriptivo observacional, e…
Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing.
1998
Abstract During 41 procedures of intramedullary nailing of femoral and tibial fractures, the primary surgeon and the first assistant wore ring dosimeters on their dominant index fingers. While the average fluoroscopy time per procedure was 4.6 min, the average dose of radiation to the dominant hand of the primary surgeon was 1.27 mSv and 1.19 mSv to the first assistant. The dose limit for the extremities is 500 mSv per year, as recommended by the International Commission on Radiological Protection. Extrapolation of the mean dose of the primary surgeon and first assistent per procedure of 1.23 mSv leads to the result that the recommended dose limit of 500 mSv would only be exceeded if more t…
The rodent tibia fracture model: A critical review and comparison with the complex regional pain syndrome literature
2018
Abstract Distal limb fracture is the most common cause of complex regional pain syndrome (CRPS), thus the rodent tibia fracture model (TFM) was developed to study CRPS pathogenesis. This comprehensive review summarizes the published TFM research and compares these experimental results with the CRPS literature. The TFM generated spontaneous and evoked pain behaviors, inflammatory symptoms (edema, warmth), and trophic changes (skin thickening, osteoporosis) resembling symptoms in early CRPS. Neuropeptides, inflammatory cytokines, and nerve growth factor (NGF) have been linked to pain behaviors, inflammation, and trophic changes in the TFM model and proliferating keratinocytes were identified …
The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
2013
Displaced distal tibia fractures require stable fixation while minimizing secondary damage to the soft tissues by the surgical approach and implants. Antegrade intramedullary nailing has become an alternative to plate osteosynthesis for the treatment of distal metaphyseal fractures over the past two decades. While retrograde intramedullary nailing is a standard procedure in other long bone fractures, only few attempts have been made on retrograde nailing of tibial fractures. The main reasons are difficulties of finding an ideal entry portal and the lack of an ideal implant for retrograde insertion. The Retrograde Tibial Nail (RTN) is a prototype intramedullary implant developed by our group…