Search results for "Time of Flight"
showing 10 items of 114 documents
Multi-MHz time-of-flight electronic bandstructure imaging of graphene on Ir(111)
2016
In the quest for detailed spectroscopic insight into the electronic structure at solid surfaces in a large momentum range, we have developed an advanced experimental approach. It combines the 3D detection scheme of a time-of-flight momentum microscope with an optimized filling pattern of the BESSY II storage ring. Here, comprehensive data sets covering the full surface Brillouin zone have been used to study faint substrate-film hybridization effects in the electronic structure of graphene on Ir(111), revealed by a pronounced linear dichroism in angular distribution. The method paves the way to 3D electronic bandmapping with unprecedented data recording efficiency.
Long axial crystals for PET applications: The AX-PET demonstrator and beyond
2013
The usage of long, axially oriented scintillator crystals in a PET scanner has been shown by the AX-PET Demonstrator as a possible solution for a high resolution and high sensitivity PET detector. In the AX-PET implementation, arrays of wavelength shifting (WLS) strips, placed orthogonally behind every crystal layer, are used to define the axial coordinate. After extensive characterization measurements, the AX-PET Demonstrator has been successfully used for the reconstruction of several phantoms and a few rodents. Possible extensions of the AX-PET concept towards Time Of Flight capabilities have been investigated, using Philips digital SiPMs as alternative photodetector. Promising CRT value…
Effects of the process conditions on the plume of a laser-irradiated indium–tin-oxide target
2001
Abstract The plume of a laser-ablated indium–tin-oxide target was investigated by optical emission spectroscopy. Atomic and ionic species of indium, tin and oxygen were observed; moreover, molecular bands of indium oxide were identified in the fluorescent spectra. The effects of the oxygen as a background gas and of the laser fluence on the behaviour of the ejected particles were studied with respect to the intensity of the emission and the delay time as a function of the observation distance from the target surface. The non-linear behaviour of the fluorescent species with the process conditions could infer spatial variations of the plume composition. The analysis demonstrates a plume expan…
Optimization of the preanalytical steps of matrix-assisted laser desorption ionization-time of flight mass spectrometry identification provides a fle…
2012
ABSTRACT We report here that modifications of the preanalytical steps of matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) identification of yeasts, with regard to the original protocol provided by the manufacturers, appear to be efficient for the reliable routine identification of clinical yeast isolates in medical laboratories. Indeed, when one colony was sampled instead of five and the protein extraction protocol was modified, the performance of MALDI-TOF MS was superior to that of the API ID 32C method (discrepancies were confirmed by using molecular identification), allowing the correct identification of 94% of the 335 clinical isolates prospec…
Development of a Novel Method for Identification of Alaria alata Mesocercariae by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spe…
2021
Alaria (A.) alata mesocercariae (AM) have increasingly appeared as incidental findings during the mandatory inspection of wild boars for Trichinella in many European countries. An Alaria spp.-specific PCR is available for the identification of AM
GEANT4 simulation of the neutron background of the C6D6 set-up for capture studies at n_TOF
2014
The neutron sensitivity of the C6D6 detector setup used at n_TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has beeni mplemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with anatC sample, showing an excellent agreement above 1 keV. At lower energies, an additional compo…
Advances in surface ion suppression from RILIS: Towards the Time-of-Flight Laser Ion Source (ToF-LIS)
2016
Abstract We present results from the development towards the Time-of-Flight Laser Ion Source (ToF-LIS) aiming for the suppression of isobaric contaminants through fast beam gating. The capability to characterize high resistance ion sources has been successfully demonstrated. A ninefold selectivity gain has been achieved through suppression of surface ionized potassium, while maintaining >90% transmission for laser-ionized gallium using a thin wall graphite ionizer cavity combined with a fast beam gate. Initial results from the investigation of glassy carbon as a potential hot cavity ion source are presented. Power-cycle tests of a newly designed mount for fragile ion source cavities indicat…
A study of solar thermal absorber stack based on CrAlSiNx/CrAlSiNxOy structure by ion beams
2019
Renewable energies are foreseen as a major energy resource for next generations. Among several energy sources and technologies available, Concentrated Solar Power (CSP) technology has a great potential, but it needs to be optimised, in particular to reduce the costs, with an increase of the operating temperature and long term stability. This goal can be achieved by tailoring the composition and multilayer structure of films. In this work we present and discuss the results obtained from solar absorber coatings based on nitride/oxynitride structures. A four-layer film structure, W/CrAlSiNx(HA)/CrAlSiNxOy(LA)/SiAlOx, was deposited on stainless steel substrates using magnetron sputtering deposi…
Low-energy heavy-ion TOF-ERDA setup for quantitative depth profiling of thin films
2008
Abstract Low-energy heavy-ion time-of-flight elastic recoil detection analysis (TOF-ERDA) is becoming a mature technique for accurate characterization of thin films. In combination with a small tandem accelerator (∼2 MV terminal voltage) and beam energies below 20 MeV, it is suitable for routine analysis of key materials in semiconductor technology. In this paper we discuss advantages and drawbacks of low-energy ERDA, compared to high-energy ERDA, in terms of depth and mass resolution, detection efficiency for light elements, sample irradiation damage and quantification accuracy. The results presented are obtained with the time-of-flight telescope recently developed at IMEC. The time-of-fli…
First tests of the applicability of gamma-ray imaging for background discrimination in time-of-flight neutron capture measurements
2015
In this work we explore for the first time the applicability of using $\gamma$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a $^{197}$Au sample have been carried out at n_TOF, achieving an enhancement of a factor…