Search results for "Time resolution"
showing 8 items of 38 documents
Stroboscopic XMCD-PEEM Imaging
2007
Abstract This article summarizes recent results on magnetization dynamics obtained with time-resolved photoemission electron microscopy (PEEM) using X-ray magnetic circular dichroism as contrast mechanism. Time resolution is performed by a stroboscopic technique that is exclusively sensitive to reversible processes, but offers a very high time resolution only limited by the X-ray pulse width. A time resolution of 20 ps in combination with a lateral resolution of 100 nm has been achieved.
MuPix7 - A fast monolithic HV-CMOS pixel chip for Mu3e
2016
The MuPix7 chip is a monolithic HV-CMOS pixel chip, thinned down to 50 \mu m. It provides continuous self-triggered, non-shuttered readout at rates up to 30 Mhits/chip of 3x3 mm^2 active area and a pixel size of 103x80 \mu m^2. The hit efficiency depends on the chosen working point. Settings with a power consumption of 300 mW/cm^2 allow for a hit efficiency >99.5%. A time resolution of 14.2 ns (Gaussian sigma) is achieved. Latest results from 2016 test beam campaigns are shown.
First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform
2020
The ProtoDUNE-SP detector was constructed and operated on the CERN Neutrino Platform. We thank the CERN management for providing the infrastructure for this experiment and gratefully acknowledge the support of the CERN EP, BE, TE, EN, IT and IPT Departments for NP04/ProtoDUNE-SP. This documentwas prepared by theDUNEcollaboration using the resources of the Fermi National Accelerator Laboratory (Fermilab), a U.S. Department of Energy, Office of Science, HEP User Facility. Fermilab is managed by Fermi Research Alliance, LLC (FRA), acting under Contract No. DE-AC02-07CH11359. This work was supported by CNPq, FAPERJ, FAPEG and FAPESP, Brazil; CFI, IPP and NSERC, Canada; CERN; MSMT, Czech Republi…
Determination of Synchronization of Electrical Activity in the Heart by Shannon Entropy Measure
2005
In this paper we propose a new index of synchronization for the study of heart’s electrical activity during atrial fibrillation (AF). The index relies on the measure of the time delays between correspondent activations in two atrial electrograms and on the characterization of their dispersion by a measure of Shannon Entropy. The algorithm was validated on simulated signals mimicking different degree of synchronization. Results showed the index was able to discriminate among different levels of organization, provided that it works on series of at least 50 activations (time resolution of almost 10 sec during AF). Moreover, we applied the algorithm to real bipolar electrograms, obtained from a…
High Resolution Time Domain Reflectometry for Dielectric State Monitoring in High Voltage Cables
2017
A high resolution Time Domain Reflectometry system has been designed in order to investigate the possibility of measuring with good accuracy the dielectric properties of high voltage cables insulator materials by means of Time-of-Flight measures. The system employs a dedicated Time-To-Digital Converter in order to achieve a time resolution of 90 ps. By exploiting averaging techniques the resolution has been further increased. Experimental results showed the possibility of measuring the dielectric constant with a resolution of 0.03%.
Developing an economically advantageous wind forecasting method for electricity market design with a 15-minute imbalance settlement period
2019
According to legal framework developed by European Commission all EU Member States shall employ 15minute time resolution for imbalance settlement no later than 18th of December 2020 (or 1st of January 2025 in case of derogation). For intermittent energy sources that are traditionally associated with less precise generation forecasts this might result in considerable increase in imbalance costs. This presents a unique challenge for wind power station operators as there is lack of adequate forecasting tools supporting 15-minute time-resolution. The objective of this paper is to test and provide comparative analysis of alternative data interpolation methods in order to determine approach assoc…
Passive vs. active degassing modes at an open-vent volcano (Stromboli, Italy)
2012
Abstract We report here on a UV-camera based field experiment performed on Stromboli volcano during 7 days in 2010 and 2011, aimed at obtaining the very first simultaneous assessment of all the different forms (passive and active) of SO 2 release from an open-vent volcano. Using the unprecedented spatial and temporal resolution of the UV camera, we obtained a 0.8 Hz record of the total SO 2 flux from Stromboli over a timeframe of ∼14 h, which ranged between 0.4 and 1.9 kg s −1 around a mean value of 0.7 kg s −1 and we concurrently derived SO 2 masses for more than 130 Strombolian explosions and 50 gas puffs. From this, we show erupted SO 2 masses have a variability of up to one order of mag…
Intercomparison of SO2 camera systems for imaging volcanic gas plumes
2015
Abstract SO 2 camera systems are increasingly being used to image volcanic gas plumes. The ability to derive SO 2 emission rates directly from the acquired imagery at high time resolution allows volcanic process studies that incorporate other high time-resolution datasets. Though the general principles behind the SO 2 camera have remained the same for a number of years, recent advances in CCD technology and an improved understanding of the physics behind the measurements have driven a continuous evolution of the camera systems. Here we present an intercomparison of seven different SO 2 cameras. In the first part of the experiment, the various technical designs are compared and the advantage…