Search results for "Toe"
showing 10 items of 3824 documents
Plasmonic Stripes in Aqueous Environment Co-Integrated With Si3N4 Photonics
2018
We demonstrate the design, fabrication, and the experimental characterization of gold-based plasmonic stripes butt-coupled with low-pressure-chemical-vapor-deposition (LPCVD)-based Si3N4 waveguides for the excitation of surface-plasmon-polariton (SPP) modes in aqueous environment. Plasmonic gold stripes, in aqueous environment, with cross-sectional dimensions of 100 nm × 7 μm were interfaced with 360 nm × 800 nm Si3N4 waveguides cladded with low-temperature-oxide, exploiting linear photonic tapers with appropriate vertical (VO) and longitudinal (LO) offsets between the plasmonic and photonic waveguide facets. An interface insertion loss of 2.3 ± 0.3 dB and a plas…
Invited Article: Ultra-broadband terahertz coherent detection via a silicon nitride-based deep sub-wavelength metallic slit
2018
We present a novel class of CMOS-compatible devices aimed to perform the solid-state-biased coherent detection of ultrashort terahertz pulses, i.e., featuring a gap-free bandwidth at least two decades-wide. Such a structure relies on a 1-µm-wide slit aperture located between two parallel aluminum pads, embedded in a 1-µm-thick layer of silicon nitride, and deposited on a quartz substrate. We show that this device can detect ultra-broadband terahertz pulses by employing unprecedented low optical probe energies of only a few tens of nanojoules. This is due to the more than one order of magnitude higher nonlinear coefficient of silicon nitride with respect to silica, the nonlinear material emp…
Phase-Sensitive Detection for Optical Sensing With Porous Silicon
2012
We report on a photonic sensor with an ultralow limit of detection (LoD) based on a phase interrogation readout scheme together with an anisotropic porous silicon (PSi) membrane. First, the fabrication of porous free-standing membranes from medium doped (100) surface oriented silicon, with pore diameters suitable for the infiltration of biomolecules, around 50 nm, is reported. Then, the phase interrogation scheme for characterizing the PSi membranes is presented whose results show that while volumetric sensitivity increases with the membrane thickness, the resolution in the birefringence measurements decrease dramatically due to depolarization effects. The best LoD was found to be equal to …
Electro-optical characterization of new classes of Silicon Carbide UV photodetectors
2014
In this paper, we present the fabrication process steps and the characterization of 4H-SiC vertical Schottky UV detectors, where interdigitated strips, acting as top metal contacts, have been realized in $\hbox{Ni}_{2}\hbox{Si}$ . These devices exploit the pinch-off surface effect. $I$ – $V$ and $C$ – $V$ characteristics, as functions of temperature, were measured in dark conditions. In addition, we have carried out responsivity measurements, for wavelengths ranging from 200 to 400 nm, at varying package temperature and applied reverse bias. A comparison among devices having different strip pitch sizes has been performed, thus finding out that the 10- $\mu\hbox{m}$ pitch class demonstrates …
All-Organic Waveguide Sensor for Volatile Solvent Sensing
2019
This work was supported by ERDF 1.1.1.1 Activity Project Nr. 1.1.1.1/16/A/046 “Application assessment of novel organic materials by prototyping of photonic devices”. We acknowledge Igors MIHAILOVS for valuable discussions.
Time of flight for photon in human skin
2016
The time of flight for photons in human skin was measured using picosecond diode laser. Two different wavelength lasers were used - 405 nm and 510 nm. A difference for time of flight in normal skin and in nevus was observed as well as a difference for different wavelength laser irradiation was observed. For 405 nm laser irradiation the difference was 41 ps while comparison of time of flights skin and nevi using 510 nm irradiation showed a result of 32 ps. Results allow to conclude that the time photon travels in skin might depend on the characteristics of the medium and wavelength of the irradiation. This can be related to known data for light penetration depth in human skin for different w…
All-Fiber Laser With Intracavity Acousto-Optic Dynamic Mode Converter for Efficient Generation of Radially Polarized Cylindrical Vector Beams
2017
We report an all-fiber laser that emits a radially polarized cylindrical vector beam (CVB) at 1 μm based on an intracavity acousto-optic mode converter. We efficiently generate the CVB, taking advantage of the acousto-optic coupling from the HE11 mode to the TM01 mode in a two-mode fiber. The laser can be switched from emitting a Gaussian-like beam to a radially polarized CVB. Radially polarized CVBs with modal and polarization purities >98% and a maximum power of 65 mW were generated.
Spatial localization of hotspots in Fano-resonant plasmonic oligomers for surface-enhanced coherent anti-Stokes Raman scattering
2020
AbstractRealization of Fano resonance in plasmonic oligomers is often exploited to design efficient plasmonic substrates for surface-enhanced coherent anti-Stokes Raman scattering. Disk-type Fano-resonant plasmonic oligomers are widely used to enhance the Raman signal of the probe material. Generally, hot spots are generated in those oligomers at different spatial locations at different wavelengths and only a few spatially overlapping hot spots at multiple wavelengths can be achieved with oblique incidence of excitation light. In this work, we proposed hexagonal gold nanoparticle based Fano-resonant plasmonic oligomers that can yield higher number of spatially overlapped hot spots compared …
Employing Microwave Graphene Field Effect Transistors for Infrared Radiation Detection
2018
In this work, we investigate the possibility of employing graphene field effect transistors, specifically designed for microwave applications, as infrared detectors for telecom applications. Our devices have been fabricated on a sapphire substrate employing CVD-grown transferred graphene. The roles of both the gate dielectric and the DC bias conditions have been evaluated in order to maximize the infrared generated signal through an experimental investigation of the signal-to-noise ratio dependence on the transistor operating point.
Supercontinuum Generation and Intermodal Four-Wave Mixing in a Step-Index Few-Mode Fibre
2019
International audience; The complex spatiotemporal dynamics of nonlinear light propagation in multimode fibers (MMFs) has recently witnessed a renewed interest because of their experimental realization in emerging key areas of laser physics and fiber optics [1]. Specifically, MMFs have a number of linear and nonlinear optical properties that make them very attractive to investigate new spatiotemporal effects fundamentally different from standard single-mode fibers. These include the observation of multimode solitons [2], intermodal four-wave mixing (FWM) [3], geometric parametric instabilities [4], spatial beam self-cleaning [5], and the generation of supercontinuum (SC) light when pumping …