Search results for "Toe"
showing 10 items of 3824 documents
Photoluminescence in Er-doped 0.4Na1/2Bi1/2TiO3-(0.6-x)SrTiO3-xPbTiO3 solid solutions
2020
Photoluminescence and optical second harmonic generation in Er-doped 0.4Na0.5Bi0.5TiO3-(0.6-x)SrTiO3-xPbTiO3 solid solutions is studied. Earlier, it was shown that upon increasing of PbTiO3 concent...
2021
Atomic layer deposition (ALD) technology has unlocked new ways of manipulating the growth of inorganic materials. The fine control at the atomic level allowed by ALD technology creates the perfect conditions for the inclusion of new cationic or anionic elements of the already-known materials. Consequently, novel material characteristics may arise with new functions for applications. This is especially relevant for inorganic luminescent materials where slight changes in the vicinity of the luminescent centers may originate new emission properties. Here, we studied the luminescent properties of CaS:Eu by introducing europium with oxygen ions by ALD, resulting in a novel CaS:EuO thin film. We …
Suppression of the vacuum space-charge effect in fs-photoemission by a retarding electrostatic front lens
2021
Review of scientific instruments 92(5), 053703 (2021). doi:10.1063/5.0046567
Compact setup for spin-, time-, and angle-resolved photoemission spectroscopy.
2020
Review of scientific instruments 91(6), 063001 (2020). doi:10.1063/5.0004861
Radiation hardness studies of CdTe and for the SIXS particle detector on-board the BepiColombo spacecraft
2009
Abstract We report of the radiation hardness measurements that were performed in the developing work of a particle detector on-board ESA's forthcoming BepiColombo spacecraft. Two different high- Z semiconductor compounds, cadmium telluride (CdTe) and mercuric iodide (HgI 2 ), were irradiated with 22 MeV protons in four steps to attain the estimated total dose of 10 12 p / cm 2 for the mission time. The performance of the detectors was studied before and after every irradiation with radioactive 55 Fe source Mn K α 5.9 keV emission line. We studied the impact of the proton beam exposure on detector leakage current, energy resolution and charge collection efficiency (CCE). Also the reconstruct…
Hydrogen plasma induced photoelectron emission from low work function cesium covered metal surfaces
2017
Experimental results of hydrogen plasma induced photoelectron emission from cesium covered metal surfaces under ion source relevant conditions are reported. The transient photoelectron current during the Cs deposition process is measured from Mo, Al, Cu, Ta, Y, Ni, and stainless steel (SAE 304) surfaces. The photoelectron emission is 2–3.5 times higher at optimal Cs layer thickness in comparison to the clean substrate material. Emission from the thick layer of Cs is found to be 60%–80% lower than the emission from clean substrates. peerReviewed
Framework for complex quantum state generation and coherent control based on on-chip frequency combs
2018
Integrated frequency combs introduce a scalable framework for the generation and manipulation of complex quantum states (including multi-photon and high-dimensional states), using only standard silicon chip and fiber telecommunications components.
Defect-induced blue luminescence of hexagonal boron nitride
2016
Abstract Native defect-induced photoluminescence around 400 nm (blue luminescence - BL) was studied in hBN materials with different size and various origins. The following spectral characterizations were used: spectra of luminescence and its excitation, luminescence dependence on temperature, luminescence kinetics, optically stimulated luminescence and infrared absorption. It was found, that the BL is characteristic for all these materials, which were studied. The BL forms a wide, asymmetric and phonon-assisted emission band at 380 nm. This luminescence can be excited either through the exciton processes, or with light from two defect-induced excitation bands at 340 nm and 265 nm. It was fo…
A graphene-based neutral particle detector
2019
A neutral particle detector is presented, in which the traditionally used target material, indium tin oxide (ITO), is replaced by graphene. The graphene-based detector enables collinear photodetachment measurements at a significantly shorter wavelength of light down to 230 nm compared to ITO-based detectors, which are limited at 335 nm. Moreover, the background signal from the photoelectric effect is drastically reduced when using graphene. The graphene based detector, reaching 1.7 eV further into the UV energy range, allows increased possibilities for photodetachment studies of negatively charged atoms, molecules, and clusters.A neutral particle detector is presented, in which the traditio…
Microfabricated high temperature sensing platform dedicated to scanning thermal microscopy (SThM)
2018
Abstract The monitoring of heat flux is becoming more and more critical for many materials and structures approaching nanometric dimensions. Scanning Thermal Microscopy (SThM) is one of the tools available for thermal measurement at the nanoscale and requires calibration. Here we report on a micro-hotplate device made of a platinum heater suspended on thin silicon nitride (SiN) membranes integrating specific features for SThM calibration. These heated reference samples can include a localized resistive temperature sensors (RTD) or standalone platinum membranes (typically 10 × 10 μm2) on which the temperature can be measured precisely. This functional area is dedicated to (1) estimate the th…