Search results for "Tonometry"
showing 10 items of 67 documents
CD36 gene is associated with intraocular pressure elevation after intravitreal application of anti-VEGF agents in patients with age-related macular d…
2017
IF 1.886; International audience; Background: The wet form of age-related macular degeneration (AMD) is characterized by pathological vascularization of the outer retinal layers. The condition responds to treatment with antibodies against vascular endothelial growth factor (VEGF), but the patients receiving such anti-VEGF therapy sometimes show undesirable acute short-term increases in the intraocular pressure (IOP). The cause of this adverse effect is unknown, and here, we are testing a hypothesis that it is related to CD36 gene polymorphisms.Materials and Methods: A group of 134 patients with AMD were given three therapeutic doses of anti-VEGF antibody (ranibizumab) at monthly intervals. …
New insights into the genetics of primary open-angle glaucoma based on meta-analyses of intraocular pressure and optic disc characteristics
2017
Item does not contain fulltext Primary open-angle glaucoma (POAG), the most common optic neuropathy, is a heritable disease. Siblings of POAG cases have a ten-fold increased risk of developing the disease. Intraocular pressure (IOP) and optic nerve head characteristics are used clinically to predict POAG risk. We conducted a genome-wide association meta-analysis of IOP and optic disc parameters and validated our findings in multiple sets of POAG cases and controls. Using imputation to the 1000 genomes (1000G) reference set, we identified 9 new genomic regions associated with vertical cup-disc ratio (VCDR) and 1 new region associated with IOP. Additionally, we found 5 novel loci for optic ne…
Goldmann Tonometry After Hyperopic Laser In Situ Keratomileusis
2004
PURPOSE To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. METHODS In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. RESULTS Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/-…
Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields
1996
Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…
Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects
2006
To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…
The relationship between central corneal thickness and Goldmann applanation tonometry
2003
The aim of this study was to investigate the relationship between Goldmann applanation tonometry and central corneal thickness in a large sample of healthy eyes.Five hundred eyes of 500 subjects (253 women, 50.6 per cent and 247 men, 49.4 per cent) were analysed in a prospective healthy population study. Mean age of the sample was 31 +/- 8 years. Goldmann applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter (DGH Technology Inc, San Diego, USA). Ten measurements were made at the centre of the cornea of each eye. The low…
Noninvasive measurement of intracranial pressure: Is it possible?
2007
BACKGROUND: Some publications suggest a strong correlation between the intracranial pressure and the intraocular pressure. Other studies claim no correlation between these two physiologic variables. Our aim was to study whether the tonometry could be a useful method to evaluate intracranial pressure in patients with suspected intracranial abnormality. METHODS: We evaluated the correlation between the intracranial pressure and the intraocular pressure, the intracranial pressure and the mean arterial pressure, and the intraocular pressure and the mean arterial pressure in 22 patients, initially comatose, who were admitted to our hospital. All patients required the intracranial pressure monito…
Analysis of Autoantibodies Against Human Retinal Antigens in Sera of Patients with Glaucoma and Ocular Hypertension
2008
The aim of this study was to show that complex antibody patterns against retinal antigens in sera of patients with glaucoma, found in previous studies, are autoantibodies against human antigens.Sera of 179 patients were collected at the Department of Ophthalmology (University of Mainz, Germany): non-glaucomatous control patients (n=45), primary open-angle glaucoma (n=45), ocular hypertension (n=44), and normal tension glaucoma patients (n=45). The sera were tested against Western blots of human retinal antigens. IgG antibody patterns were analyzed by multivariate statistical techniques, and some significant antigens were identified by mass spectrometry.All subjects, even healthy ones, showe…
Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers
2005
Background/aim: TGDc-01 is a new, portable, transpalpebral tonometry device. The aim of this study was to evaluate the reproducibility of this method, including intraobserver and interobserver deviations, and to compare the results with those of Goldmann applanation tonometry and palpation of intraocular pressure (IOP). Methods: A total of 40 eyes of 20 healthy volunteers were included. Two independent parallel observers (1 and 2) performed three replicate measurements per eye, respectively, both using TGDc01 tonometry, one observer (3) performed three replicate measurements using Goldmann applanation tonometry, and one observer (4) measured the IOP via palpation. Intraindividual deviations…
Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension.
2002
Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open angle glaucoma (POAG) and high IOP, normal tension glaucoma (NTG), and ocular hypertension (OHT). Furthermore, the authors examined whether there were any correlations with blood pressure.80 subjects were divided into four groups (n=20): 20 patients each with POAG, NTG, and OHT and 20 volunteers without any ocular pat…