Search results for "Tooth"
showing 10 items of 910 documents
Volumetric variation of peri-implant soft tissues in convergent collar implants and crowns using the biologically oriented preparation technique (BOP…
2018
Background To evaluate the changes in the peri-implant soft tissues of convergent collar implants with biologically oriented preparation technique (BOPT) crowns, 10 months after loading. Material and Methods A pilot study was carried out from January 2016 to October 2017 involving 14 patients with one or two implants in the posterior mandibular sector. A total of 32 convergent collar implants were placed using a non-submerged protocol. Three months later the provisional cemented crowns were fitted using the BOPT approach with the finish line 1-1.5 mm below the gingival margin, simulating coronal emergence of a natural tooth. The soft tissue changes were measured with an intraoral scanner at…
Using ultrasound transmission velocity to analyse the mechanical properties of teeth after in vitro, in situ, and in vivo irradiation.
2000
Ultrasound transmission velocity (UTV) in isotropic material as a measure for the modulus of elasticity was correlated to mechanical properties. Changes in micromechanical properties of radiated teeth and influence of the oral cavity were to be evaluated nondestructively. UTV was measured in extracted teeth after 36 Gy and 62 Gy of in situ (enorally, with no contact to the oral cavity) and in vitro irradiation. Relative to controls, teeth subjected to 62 Gy in vivo showed higher UTV values for dentine and enamel. Sound teeth irradiated with 60 Gy in situ also showed higher UTV values for enamel, whereas dentine values were not significantly different from those of control. The mechanical pr…
Accuracy evaluation of orthodontic movements with aligners: a prospective observational study.
2022
Abstract Background Since their introduction in orthodontics, clear aligners have been appreciated by patients, including adults, for their comfort and low aesthetic impact. Despite the enormous mobilization of financial resources all over the world aimed at producing new product lines, few clinical studies or high-quality evidence have been produced regarding the real effectiveness of such treatment. Given the few limited kinds of research on the subject, this study aims to produce and critically evaluate other data, to establish the concrete reliability of clear aligners in orthodontic therapy. Results Significant sample sizes were obtained for intrusion, vestibulo/lingual (V/L) crown tip…
Root resorption and orthodontic treatment. Review of the literature.
2007
The aim of this paper was to provide a systematic review of the literature on the root resorption caused by orthodontic treatment. Original papers on this subject, published in English from January 2000 until December 2005, were located in the MEDLINE/PubMed database. Other sources were taken from the references of the selected papers. Root resorption is the most common sequela of the orthodontic treatment. It is an inflammatory process that leads to an ischemic necrosis localized in the periodontal ligament when the orthodontic force is applied. The onset and progression of root resorption are associated with risk factors related to the orthodontic treatment such as the duration of treatme…
Implant insertion torque value in immediate loading : a retrospective study
2019
Background The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. Material and Methods In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant difference…
Performance Study of Non-beaconed and Beacon-Enabled Modes in IEEE 802.15.4 under Bluetooth Interference
2008
The IEEE 802.15.4 protocol is a flexible technology with great potential for wireless sensor networks applications. The standard distinguishes two network modes; beacon-enabled and nonbeacon-enabled. In this paper, the performance study of beaconed and non-beaconed modes of IEEE 802.15.4 is evaluated using on site PER measurements. The tests are carryout in an urban outdoor environment with commercial available equipment. Likewise, the impact of Bluetooth interference over IEEE 802.15.4 modes is evaluated. The results show that Bluetooth interference and the mode selected have effects over the PER. Furthermore, for distances between 3 to 10 meters the PER doesn't show significance distance …
Universally Designed Beacon-Assisted Indoor Navigation for Emergency Evacuations
2019
International audience; The United Nations (UN) Convention on the Rights of Persons with Disabilities (CRPD) obligates national governments to ensure the protection and safety of persons with disabilities in emergency situations. This article examines the application and accessibility of state-of-the-art ICT solutions in emergency situations. Research has indeed shown that the design and implementation of evacuation procedures in emergency situations play a critical role in ensuring personal safety and protection. While research has examined the experiences of persons including persons with disabilities in emergency situations, research has yet to examine fully the role that cutting-edge in…
Comparison of the efficacy of low doses of methylprednisolone, acetaminophen, and dexketoprofen trometamol on the swelling developed after the remova…
2015
WOS: 000365269900016
Application of L-PRF for socket preservation of an anterior fractured tooth in a young patient: a case report
2020
The 4th international comparison on EPR dosimetry with tooth enamel: Part 1: Report on the results
2011
This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provided by the organizers. Nine molar teeth extracted following medical indication from German donors and collected between 1997 and 2007 were prepared and irradiated at the Helmholtz Zentrum München. Five out of six samples were irradiated at 0.1, 0.2, 0.5, 1.0 and 1.5 Gy air kerma; and one unirradiated s…