Respiratory mechanics measured by forced oscillations during mechanical ventilation through a tracheal tube
2011
The forced oscillation technique (FOT) allows the measurement of respiratory mechanics in the intensive care setting. The aim of this study was to compare the FOT with a reference method during mechanical ventilation through a tracheal tube. The respiratory impedance spectra were measured by FOT in nine anaesthetized pigs, and resistance and compliance were estimated on the basis of a linear resistance-compliance inertance model. In comparison, resistance and compliance were quantified by the multiple linear regression analysis (LSF) of conventional ventilator waveforms to the equation of motion. The resistance of the sample was found to range from 6 to 21 cmH(2)O s l(-1) and the compliance…
Evaluation of the novel, single-use, flexible aScope® for tracheal intubation in the simulated difficult airway and first clinical experiences
2010
Flexible fibreoptic intubation is widely accepted as an important modality for the management of patients with difficult airways. We compared the aScope, a novel, single-use, flexible video-endoscope designed to aid tracheal intubation, with a standard flexible intubating fibrescope, by examining the performance of 21 anaesthetists during an easy and difficult intubation simulation in a manikin. Intubation success, time for intubation, and rating of the devices (using a scale from 1, excellent to 6, fail) were documented. Intubation times were similar for both flexible 'scopes in the scenarios (p = 0.59). Successful intubation rates were higher for the standard intubating fibrescope (17/21,…
Performance of the C-MAC video laryngoscope in patients after a limited glottic view using Macintosh laryngoscopy
2011
We applied the C-MAC videolaryngoscope in 52 consecutive patients who were found to have an unexpected Cormack and Lehane grade-3 (n = 49) and grade-4 (n = 3) laryngeal view with the Macintosh laryngoscope. The glottic view improved in 49 (94%) patients using the C-MAC. Tracheal intubation was successful in 49 of 52 patients (94%). In one patient, tracheal intubation failed using the C-MAC despite the presence of a Cormack and Lehane grade-2. These results suggest that the C-MAC videolaryngoscope has a role as a rescue device in cases of an initially difficult laryngeal view.
Vitamin A in parenteral nutrition: uptake and distribution of retinyl esters after intravenous application.
1989
Short-term parenteral application of vitamin A was examined in rats. Retinyl margarinate, which is chemically similar to physiological retinyl esters, was used in vitamin A-depleted rats to study uptake, distribution, and storage of retinyl esters in tissues. Vitamin A-depleted and Vitamin A-sufficient rats were infused with a micellar suspension of retinyl margarinate for 7 h and then killed at different times. Retinyl margarinate was directly taken up by all tissues examined. It appears that infusion of retinyl esters in micellar form provides a direct way to supply vitamin A to peripheral, vitamin A-dependent tissues. Therefore, a short-term infusion of retinyl esters with an emulsifier …
The Combitube, Self-Inflating Bulb, and Colorimetric Carbon Dioxide Detector to Advance Airway Management in the First Echelon of the Battlefield
2006
Combat lifesavers and Army medics are regular combat soldiers who possess skills that enable them to provide lifesaving assistance to combat casualties. Although their training is not equal to that of paramedics, combat lifesavers and Army medics are trained to assess casualties for airway obstruction, as well as the presence or absence of spontaneous ventilation. They are also familiar with the same basic airway maneuvers that are required for blind insertion of the esophageal-tracheal double-lumen airway (ETDLA). Use of the ETDLA in combination with an esophageal detector device and a colorimetric carbon dioxide detector would require skill similar to that which they already possess in pe…
Blood CO2 and pH Transients During Apnoea after O2 Breathing in Patients
1990
Endotracheal intubation always is combined with an apnoea the duration of which is dependent on the technique used, the skills of the intubator, and the anatomical situation. The resulting typical potential risks may be (among others) both hypoxaemia and hypercapnia. Therefore the tolerable apnoea time for an intubation procedure is limited in clinical practice to 1 – 2 minutes. It must be noted that the developing hypercapnia is inevitable, whereas hypoxaemia may be avoided even in prolonged apnoea (e.g. >2 min) with “adaequate” preoxygenation [Duda et al., 1988]. Using de-nitrogenation techniques (breathing pure oxygen for 30 to 60 min) “anaesthetized and curarized normal subjects tolerat…
Anestesisykepleieres metoder for å kontrollere cufftrykk – en observasjonsstudie
2021
Bakgrunn: Forskning viser at pasienter i generell anestesi som har fått sine luftveier sikret med en larynxmaske eller en endotrakealtube opplever postoperative pharyngolaryngeale komplikasjoner. Et kontrollert cufftrykk har vist reduksjon i komplikasjoner.
 Hensikt: Hensikten med studien var å undersøke hvilke metoder anestesisykepleiere bruker for å kontrollere cufftrykk, og hvilke begrunnelser de har for å bruke cufftrykkmanometer.
 Metode: Totalt 45 anestesisykepleiere ble observert når de kontrollerte cufftrykket i en endotrakealtube og en larynxmaske. Anestesisykepleierne ble i tillegg spurt om hvilke begrunnelser de hadde for å bruke eller ikke bruke cufftrykkmanometer.�…
A new device for emergency airway management: the EasyTube.
2003
Ein Mikro-Atemstromventil für spontan atmende narkotisierte Kleintiere - A Respiratory Micro-Valve for Spontaneously Breathing Anaesthetized Small An…
1994
For the accurate functional analysis of the gas exchange in the lungs or evaluation of artificial oxygen carriers in spontaneously breathing anaesthetized small animals, we developed a new respiratory micro-valve. The body of the valve is made of aluminium, and the flaps are made of silicone rubber. The maximum flow rate in a rat measured with a pneumotachograph and the micro-valve was an average of 19.9 ml/s during inspiration, and 17.8 ml/s during expiration. The pressure measured in the tracheal tube was -0.85 during inspiration, and +0.39 cm H2O during expiration; the end-expiratory pressure in the tube was zero. In two experiments with anaesthetised rats lasting 4-5 hours, ventilation,…
Is Persistent Thick Copious Mucus a Long-Term Symptom of COVID-19?
2020
Introduction The typical clinical picture of COVID-19 is gradually becoming clearer, both in the acute phase and in the long-term. However, new symptoms are gradually being identified. We describe a long-term symptom that has not yet been reported. Case description A 49-year-old man consulted for persistent asthenia. The general practitioner found a fever (39.2°C), and COVID-19 was confirmed by the polymerase chain reaction test. Further symptoms appeared, notably thick, white, painless tracheal hypersecretion for 3 months before diminishing, without disappearing. Conclusion Non-inflammatory tracheal hypersecretion, not yet reported in COVID-19, may be an additional long-term symptom. The h…