Search results for "Transducer"
showing 10 items of 173 documents
Real-time and low-cost sensing technique based on photonic bandgap structures
2011
[EN] A technique for the development of low-cost and high-sensitivity photonic biosensing devices is proposed and experimentally demonstrated. In this technique, a photonic bandgap structure is used as transducer, but its readout is performed by simply using a broadband source, an optical filter, and a power meter, without the need of obtaining the transmission spectrum of the structure; thus, a really low-cost system and real-time results are achieved. Experimental results show that it is possible to detect very low refractive index variations, achieving a detection limit below 2 x 10(-6) refractive index units using this low-cost measuring technique. (C) 2011 Optical Society of America[
Characterization of Current Transformers in the Presence of Harmonic Distortion
2008
The CTs performance under distorted conditions are usually characterized by means of the frequency response test. In this paper a new way to characterize CTs, closer to real operative conditions, is proposed. The harmonic phase angle and ratio errors are measured when the CTs are excited with a nonsinusoidal current composed of a fundamental and one harmonic, with adjustable phase shift. The errors measured using the new approach were found larger than the ones obtained with the frequency response. This suggests that frequency response is not a reliable method to evaluate the CT performance under distorted conditions.
Experimental Investigation of Random Vibration Control Through Dry Friction
1997
The purpose of this experimental investigation is to measure the response statistics in the presence of base friction and other friction sources. The experimental model emulates a one-floor building supported on four leaf springs, subjected to band limited random excitation. Two different types of model base are considered, a friction base and a frictionless base. In both cases friction can also be applied at two sides of the model’s main mass against the direction of its motion. Excitation and response transducer signals are processed to estimate excitation and response statistics in the presence and in the absence of top mass friction. Measured statistics include mean squares, autocorrela…
Effect of Acoustic Wave Reflections on Space Charge Measurements with PEA Method
2018
The Pulsed Electro-Acoustic (PEA) method is the most used technique for space charge detection in solid dielectrics. The methodology is largely employed in the field of High Voltage Direct Current (HVDC) transmission and is based on the detection of acoustic waves generated by charges vibration. One of the most common problems arising during the detection is the presence of multiple reflections taking place due to the presence of means discontinuity in the different PEA cell components. This reflection phenomenon, if not well taken into account, could cause incorrect interpretation of the PEA output signal. It is easy to understand that a simulation model is a basic tool to understand the w…
246. Analysis of signal-to-noise ratio for a 2-channels coil developed to enable transcranial Magnetic Resonance-guided Focused Ultrasound Surgery (t…
2018
Abstract Purpose In recent years trans-cranial Magnetic Resonance-guided Focused Ultrasound Surgery (tcMRgFUS) treatments have aroused large scientific and medical interest [1] . Usually, tcMRgFUS systems are integrated with 3 T systems which allow the use of the body RF coil for both real time imaging and MR-thermometry. At University Hospital of Palermo there is the world-first installation of a tcMRgFUS system integrated with a 1.5 T scanner. Here we present the characterization in terms of signal-to-noise ratio (SNR) of a dedicated RF coils suitably developed (by InSightec) to enable tcMRgFUS treatments with 1.5 T MR units. Methods and materials The focused ultrasound equipment (ExAblat…
Characterization and Error Compensation of a Rogowski Coil in the Presence of Harmonics
2011
This paper reports the results of an experimental study dealing with a commercial Rogowski coil current transducer (RCCT) in the presence of harmonic distortion. The RCCT was observed under two conditions: 1) sinusoidal excitation with frequencies from 50 to 750 Hz and 2) nonsinusoidal excitation using fundamental frequency and one harmonic, with adjustable amplitude and phase shift. The experimental results show only a weak dependence of the harmonic current ratio error and phase displacement on the amplitude and phase shift of the excitation harmonic. The phase displacement is also independent of the conductor position within the Rogowski coil window. An error compensation method, based o…
A 20-channel receive-only mouse array coil for a 3 T clinical MRI system
2011
A 20-channel phased-array coil for MRI of mice has been designed, constructed, and validated with bench measurements and high-resolution accelerated imaging. The technical challenges of designing a small, high density array have been overcome using individual small-diameter coil elements arranged on a cylinder in a hexagonal overlapping design with adjacent low impedance preamplifiers to further decouple the array elements. Signal-to-noise ratio (SNR) and noise amplification in accelerated imaging were simulated and quantitatively evaluated in phantoms and in vivo mouse images. Comparison between the 20-channel mouse array and a length-matched quadrature driven small animal birdcage coil sh…
Piezoelectric model of rainfall energy harvester
2014
In this paper a model to predict the harvest of the energy contained in rainfall by means of piezoelectric transducers is presented. Different studies agree on the level of suitable generated voltage on the electrodes of a piezoelectric transducer subjected to rainfall, but a complete characterization on the supplied power is still missing. This work, in order to limit optimistic forecasts, compares the behavior of the transducers subjected to real and artificial rainfall, a condition that has shown promising behavior in laboratory.
A Study on the Measurement Instrumentation for a Custom-Made Bipendulum Impact Testing Machine
2008
Experimental investigations of structures under impact loads are normally carried out by means of drop-weight testing rigs, which are often tailor made, and require sensors for fast transient measurement of mechanical quantities (namely, force, displacement, velocity, and absorbed energy). Since these tests are quite expensive, time consuming, and, often, not repeatable, the sensors must provide reliable and interpretable results in the first trial. In this paper, a thorough study on the measurement instrumentation suitable to carry out reliable low-velocity impact tests by means of a custom-made bipendulum impact testing machine is presented. Attention has been focused on the choice of the…
Transducers for the bidirectional decoding of prefix codes
2010
AbstractWe construct a transducer for the bidirectional decoding of words encoded by the method introduced by Girod (1999) in [5] and we prove that it is bideterministic and that it can be used both for the left-to-right and the right-to-left decoding.We also give a similar construction for a transducer that decodes in both directions words encoded by a generalization of Girod’s encoding method. We prove that it has the same properties as those of the previous transducer. In addition we show that it has a single initial/final state and that it is minimal.