Search results for "Transfer function"
showing 10 items of 152 documents
On-eye optical quality of daily disposable contact lenses for different wearing times
2012
Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…
Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator
2013
PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …
Causal cross-spectral analysis of heart rate and blood pressure variability for describing the impairment of the cardiovascular control in neurally m…
2006
A causal approach to the calculation of coherence and transfer function between systolic pressure (SP) and RR interval variability was applied in eight patients and eight control subjects during prolonged tilt test for investigating the impairment of cardiovascular control related to neurally mediated syncope. The causal analysis showed a depressed baroreflex regulation in resting patients, with reduced gain and increased latency from SP to RR, and a drop of the baroreflex coupling immediately before syncope. These findings, which were not elicited by traditional cross-spectral analysis, strongly suggest the use of the causal approach for the study of syncope mechanisms. © 2006 IEEE.
Exploring directionality in spontaneous heart period and systolic pressure variability interactions in humans: implications in the evaluation of baro…
2004
Although in physiological conditions RR interval and systolic arterial pressure (SAP) are likely to interact in a closed loop, the traditional cross-spectral analysis cannot distinguish feedback (FB) from feedforward (FF) influences. In this study, a causal approach was applied for calculating the coherence from SAP to RR ( Ks-r) and from RR to SAP ( Kr-s) and the gain and phase of the baroreflex transfer function. The method was applied, compared with the noncausal one, to RR and SAP series taken from 15 healthy young subjects in the supine position and after passive head-up tilt. For the low frequency (0.04–0.15 Hz) spectral component, the enhanced FF coupling ( Kr-s = 0.59 ± 0.21, signi…
Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator
2013
To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…
The effect of simulated normal and amblyopic higher-order aberrations on visual performance.
2012
Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …
An improved algorithm for thermal dynamic simulation of walls using Z-transform coefficients
2003
The Transfer Function Method (TFM), recommended by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), is one of the most modern tools available to solve heat transfer problems in building envelopes and environments. TFM utilises Z-transform to solve the equations system that describes the heat transfer in a multi-layered wall. Due to an analogy with an electric circuit, it is possible to write the equations system in a matrix suitable to be solved by computer. Authors carried out an analysis on an historical building placed in the south of Italy to test the reliability and the quality of the thermal dynamic simulation using TFM. The analysis is performed usi…
Investigating the level of significance of the coherence function in cardiovascular variability analysis
2002
Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), spectral estimator parameters should also be considered. In this study, the surrogate data technique was introduced to define the level of significance of the CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate the CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parame…
The Transfer Function of Non-Stationary Indoor Channels and its Relationship to System Functions of LFMCW Radars
2021
This paper studies the relationship between the time-variant (TV) channel transfer function (CTF) of non-stationary indoor channels and the system functions of linear frequency modulated continuous waves (LFMCW) radars. To do so, we consider a moving person/object in indoor environments, which is modelled by a cluster of moving point scatterers. It is shown that the TVCTF can be obtained from the beat signal of LFMCW radar systems. Analytical expressions are derived for the TV demodulated radar response, the complex channel gain, and the TV Doppler-delay profile. A relationship between the presented results and existing non-stationary indoor channel models assuming pulsed wave systems is al…
Comparison of two different devices to assess intraocular lenses
2016
[EN] In this paper, we have compared the performance of two commercial systems, Kaleo-I and IOLA Plus, in the characterization of monofocal intraocular lenses (IOLs) according to the International Standard requirements (ISO 11979-2). The dioptric power (DP) and the Modulation Transfer Function (MTF) at 100.1p/mm and 3.0 mm aperture have been measured with both instruments in twenty commercial monofocal HEMA IOLs and their agreement was assessed by Bland Altman analysis. Compared with the designed power, IOLA Plus gave lower values in 85% of measures: Kaleo I errors are dependent on the power of the lens: measurements were higher than the designed power in the low-medium power range and lowe…