Search results for "Transform"
showing 10 items of 3975 documents
Measurements on partial discharge in on‐site operating power transformer: a case study
2018
This study presents the case study of a substation in-service power transformer referred to the on-site partial discharge (PD) detection and evaluation methods. An original methodology for simultaneous application of three methods is proposed: electrical, acoustic and ultra-high frequency. Transformer is powered by the power grid and no external generator is required according to the proposed methodology. Furthermore, several possibilities of applying these concurrent measurements and benefits of such solution in terms of result interpretation, interference resistance and on-site measurement applicability are indicated. The proposed methodology allows for a fast, accurate and secure PD diag…
Amorphous ultra-wide bandgap ZnOx thin films deposited at cryogenic temperatures
2020
Crystalline wurtzite zinc oxide (w-ZnO) can be used as a wide band gap semiconductor for light emitting devices and for transparent or high temperature electronics. The use of amorphous zinc oxide (a-ZnO) can be an advantage in these applications. In this paper we report on X-ray amorphous a-ZnOx thin films (~500 nm) deposited at cryogenic temperatures by reactive magnetron sputtering. The substrates were cooled by a nitrogen flow through the copper substrate holder during the deposition. The films were characterized by X-ray diffraction (XRD), Raman, infrared, UV-Vis-NIR spectroscopies, and ellipsometry. The a-ZnOx films on glass and Ti substrates were obtained at the substrate holder temp…
Superparamagnetic recoverable flowerlike Fe3O4@Bi2O3 core–shell with g-C3N4 sheet nanocomposite: synthesis, characterization, mechanism and kinetic s…
2019
In the present research study, a simple method was developed for the synthesis of three-dimensional flowerlike Fe3O4@Bi2O3 core–shell with g-C3N4 sheet nanocomposites. The X-ray diffraction, Fourier transform infrared spectroscopy, scanning electronic microscopy, transmission electron microscope, vibrating sample magnetometer, dynamic laser scattering analyzer and UV–Vis diffuse reflection spectroscopy were employed for the characterization of structure, purity and morphology of the resultant samples. The degradation of indigo carmine as a model of organic dye pollutant is applied for photo-catalytic activity. The parameters which are affecting the efficiency of various parameters, such as;…
Nonlinear optical response of bulk ZnO crystals with different content of intrinsic defects
2018
Abstract The nonlinear optical (NLO) properties of native defect-rich ZnO single crystals were studied in details within the excitation of the continuous wave (CW) and pulsed laser radiation at 532 nm (2.33 eV). Analysis of the experimental data of optical elastic scattering, Fourier transform infrared (FTIR), near infrared–visible–ultraviolet (NIR–Vis–UV) spectra recorded in reflection and absorption modes, and data of photoluminescence (PL) spectroscopy confirmed the contribution of both intrinsic defects and their clusters, being determined before by neutron diffraction and XRD analysis. It was shown that the high sensitivity of the NLO diagnostics via self-action of a laser beam is due …
Systematic and statistical uncertainties of the hilbert-transform based high-precision FID frequency extraction method.
2021
Abstract Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is one of the methods that have been used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described, and it is briefly compared with other commonly used frequency extraction methods. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytical…
Electromagnetic and Thermal Modelling for Calculating Ageing Rate of Distribution Transformers
2018
Prediction of the lifetime for transformers is very important for maintenance and asset management. Finite element analysis was performed on a 5 MVA distribution transformers with aluminium foil-type windings and voltage rating 6600 V/23000 V. Electromagnetic modelling is implemented on the full three-phase transformer to calculate distributed losses, taking the skin effect into account. To reduce the computational burden, the distributed losses in one phase are used to analyse temperature rise in one phase of the transformer. The temperature rise results were used to determine the ageing rate of the transformer. Further, the influence of ambient temperature and cooling on the temperature r…
A quartz amplifier for high-sensitivity Fourier-transform ion-cyclotron-resonance measurements with trapped ions
2019
Single-ion sensitivity is obtained in precision Penning-trap experiments devoted to light (anti)particles or ions with low mass-to-charge ratios, by adding an inductance coil to an amplifier connected to the trap, both operated at 4 K. However, single-ion sensitivity has not been reached on heavy singly or doubly charged ions. In this publication, we present a new system to reach this point, based on the use of a quartz crystal as an inductance, together with a newly developed broad-band (BB) amplifier. We detect the reduced-cyclotron frequency of 40Ca+ ions stored in a 7-tesla open-ring Penning trap. By comparing the detected electric signal obtained with the BB amplifier and the fluoresce…
FTIR Analysis of Electron Irradiated Single and Multilayer Si<sub>3</sub>N<sub>4</sub> Coatings
2018
Silicon nitride (Si3N4) due to its good mechanical and electrical properties is a promising material for wide range of applications, including exploitation under action of ionizing radiation. For estimating the changes of chemical bonds in silicon nitride nanolayers under action of ionizing radiation single and multi-layer silicon nitride nanolayered coatings on prepared Si subtrate were investigated by means of Fourier transform infrared spectrometry. Three main groups of signals were identified in both types of nanolayers, at 510 and 820 cm-1 and group of broad signals at 1000-1200 cm-1. Irradiation with accelerated electrons up to absorbed doses 36 MGy causes minor changes of signal inte…
A procedure for slicing and characterizing soft heterogeneous and irregular-shaped tissue
2020
Abstract This paper presents a slicing technique useful to prepare precise and repeatable samples from organs which are irregularly shaped and highly heterogeneous for mechanical testing and advanced microscopy observation. The suggested technique does not seem to influence the internal microstructure and it is employed here for testing specimens cut from different region of the meniscal tissue. Fast Fourier Transform analysis is used to quantify characteristic features of the microstructure (collagen fibers orientation, pore size) after slicing prior mechanical testing. Uniaxial (relaxation) tests are performed on dog-bone meniscal samples. Stress relaxation testing results on samples cut …
Effect of Mn doping on the low-temperature synthesis of tricalcium phosphate (TCP) polymorphs
2019
Abstract Effect of Mn doping on the low-temperature synthesis of tricalcium phosphate (TCP) polymorphs was demonstrated in α- and β-TCP polymorphs prepared by wet precipitation method under identical conditions and annealed at 700 °C. Calcium phosphates with Mn doping level in the range from 1 to 5 mol% were studied and the formation of desired polymorph was controlled by varying Mn content in as-prepared precipitates. It was found that increasing Mn content resulted in the formation of β-TCP, while α-TCP was obtained with low Mn doping level, whereas a mixture of two polymorphs was obtained for intermediate Mn concentrations. Moreover, doping with Mn ions allowed the synthesis of β-TCP at …