Search results for "Trap"
showing 10 items of 2144 documents
High-precision mass measurements for the rp-process at JYFLTRAP
2017
The double Penning trap JYFLTRAP at the University of Jyvaskyla has been successfully used to achieve high-precision mass measurements of nuclei involved in the rapid proton-capture (rp) process. A precise mass measurement of 31 Cl is essential to estimate the waiting point condition of 30 S in the rp-process occurring in type I x-ray bursts (XRBs). The mass-excess of 31 C1 measured at JYFLTRAP, -7034.7(3.4) keV, is 15 more precise than the value given in the Atomic Mass Evaluation 2012. The proton separation energy S p determined from the new mass-excess value confirmed that 30 S is a waiting point, with a lower-temperature limit of 0.44 GK. The mass of 52 Co effects both 51 Fe( p,γ ) 52 C…
Ion beam coolers in nuclear physics
2003
Cooling techniques for low-energy radioactive ion beams are reviewed together with applications on high-precision measurements of ground state properties of exotic nuclei. The emphasis in the presentation is on cooling, bunching and improving the overall characteristics of ion beams by RFQ-driven buffer gas cooling devices. Application of cooled and bunched beams in collinear laser spectroscopy to extract isotope shifts and hyperfine structure are presented with examples on radioactive Ti, Zr and Hf isotopes. The impact of the new-generation coolers on mass measurements of short-lived nuclei is discussed with examples on precision measurements of masses of super-allowed beta emitters. As a …
Accurate mass determination of short-lived isotopes by a tandem Penning-trap mass spectrometer
1990
A mass spectrometer consisting of two Penning traps has been set up for short-lived isotopes at the on-line mass separator ISOLDE at CERN. The ion beam is collected and cooled in the first trap. After delivery to the second trap, high-accuracy direct mass measurements are made by determining the cyclotron frequency of the stored ions. Measurements have been performed for $^{118}--^{137}$Cs. A resolving power of over ${10}^{6}$ and an accuracy of 1.4\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}7}$ have been achieved, corresponding to about 20 keV.
On-Line Ion Cooling and Bunching for Collinear Laser Spectroscopy
2002
A new method has been developed for increasing the sensitivity of collinear laser spectroscopy. The method utilizes an ion-trapping technique in which a continuous low-energy ion beam is cooled and accumulated in a linear Paul trap and subsequently released as a short ( $10--20\ensuremath{\mu}\mathrm{s}$) bunch. In collinear laser measurements the signal-to-noise ratio has been improved by a factor of $2\ifmmode\times\else\texttimes\fi{}{10}^{4}$, allowing spectroscopic measurements to be made with ion-beam fluxes of $\ensuremath{\sim}50\mathrm{ions}{\mathrm{s}}^{\ensuremath{-}1}$. The bunching method has been demonstrated in an on-line isotope shift and hyperfine structure measurement on r…
Highly-charged ions in a penning trap: mass measurements, etc.
1991
The use of a Penning trap will start a new generation of precision experiments on highly charged ions. The long storage time of the ions in combination with a controlled confinement in a very small volume will enable accuracies in mass determination better than δm/m = 10-8.
Penning-trap mass spectrometry and mean-field study of nuclear shape coexistence in the neutron-deficient lead region
2017
We present a study of nuclear shape coexistence in the region of neutron-deficient lead isotopes. The midshell gold isotopes 180,185,188,190Au (Z=79), the two long-lived nuclear states in 197At (Z=85), and the neutron-rich nuclide 219At were produced by the ISOLDE facility at CERN and their masses were determined with the high-precision Penning-trap mass spectrometer ISOLTRAP. The studied gold isotopes address the trend of binding energies in a region of the nuclear chart where the nuclear charge radii show pronounced discontinuities. Significant deviations from the atomic-mass evaluation were found for 188,190Au. The new trend of two-neutron separation energies is smoother, although it doe…
Restoration of theN=82Shell Gap from Direct Mass Measurements ofSn132,134
2008
A high-precision direct Penning trap mass measurement has revealed a 0.5-MeV deviation of the binding energy of (134)Sn from the currently accepted value. The corrected mass assignment of this neutron-rich nuclide restores the neutron-shell gap at N=82, previously considered to be a case of "shell quenching." In fact, the new shell gap value for the short-lived (132)Sn is larger than that of the doubly magic (48)Ca which is stable. The N=82 shell gap has considerable impact on fission recycling during the r process. More generally, the new finding has important consequences for microscopic mean-field theories which systematically deviate from the measured binding energies of closed-shell nu…
Mass Measurements of Very Neutron-Deficient Mo and Tc Isotopes and Their Impact on rp Process Nucleosynthesis
2011
The masses of ten proton-rich nuclides, including the N=Z+1 nuclides 85-Mo and 87-Tc, were measured with the Penning trap mass spectrometer SHIPTRAP. Compared to the Atomic Mass Evaluation 2003 a systematic shift of the mass surface by up to 1.6 MeV is observed causing significant abundance changes of the ashes of astrophysical X-ray bursts. Surprisingly low alpha-separation energies for neutron-deficient Mo and Tc are found, making the formation of a ZrNb cycle in the rp process possible. Such a cycle would impose an upper temperature limit for the synthesis of elements beyond Nb in the rp process.
Charge breeding rare isotopes for high precision mass measurements: challenges and opportunities
2013
Ion charge breeding for Penning-trap mass spectrometry has been established as providing a precision increase that scales linearly with the charge state of the ion. Fast and efficient charge breeding is a precondition for the application of this approach to rare isotopes. However, in view of low yields and short half-lives the precision boost is partly compromised by unavoidable ion losses inherent to the charge breeding process. The mass spectrometer TRIUMFs ion trap for atomic and nuclear science is pioneering this field by coupling a Penning trap and an electron beam ion trap to the rare-isotope beam facility ISAC at TRIUMF. Here we present simulations that calculate and maximize the eff…
Mass Determination of Francium and Radium Isotopes by a Penning Trap Mass Spectrometer
1992
Abstract A tandem Penning trap mass spectrometer is used for mass measurement of radioactive isotopes produced at the on-line isotope separator ISOLDE/CERN. The mass is determined directly and with high accuracy by measuring the cyclotron frequency of the stored ions. Measurements were performed on 209 210 211 212 221 222Fr and 226 230Ra. A resolving power of 5 × 105 was used and an accuracy of 1·8 × 10−7 has been achieved.