Search results for "Trap"
showing 10 items of 2144 documents
Trap-assisted decay spectroscopy with ISOLTRAP
2012
Penning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectroscopy has been coupled to the ISOLTRAP mass spectrometer at ISOLDE/CERN. The results from studies with stable and radioactive ions show that the setup can be used to perform decay studies on purified short-lived nuclides and to assist mass measurements. (C) 2012 Elsevier B.V. All rights reserved.
Bunching and cooling of radioactive ions with REXTRAP
2002
The properties of radioactive ion beams produced by the present on-line target ion source technology are often not suitable for direct post acceleration. For that purpose pulsed and cooled beams of higher charged ions are required. In the case of REX-ISOLDE, the post accelerator at the CERN-ISOLDE radioactive beam facility, a unique system for beam preparation is used. It consists of a gas-filled cylindrical Penning trap (REXTRAP) for bunching and cooling followed by an electron beam ion source for charge state breeding. The Penning trap has been successfully operated with an efficiency of up to 40% and a total number of up to 107 ions stored. Buffer-gas sideband cooling at the ions’ cyclot…
DIRECT PRODUCTION OF PIONIC ATOMS FROM RADIATIVE TRAPPING OF PIONS IN FLIGHT
1992
Abstract The reaction π−A→(πb−A)γ with Tπ=10−30 MeV producing a π− bound in the nucleus is studied to see its viability as an instrument to produce deeply bound pionic atoms in nuclei. We obtain cross sections of the order of tens of μb/ (sr MeV) for the production of the 1s and 2p states of 208Pb and negligible background from radiative pion capture and the other sources. The negligible background expected in the present reaction is unique among all other reactions so far proposed. The cross sections obtained are three orders of magnitude bigger than those in the best electromagnetic reactions previously proposed. The small background, the large cross sections and the present available flu…
Cooling of radioactive ions with the Penning trap REXTRAP
2005
Abstract Cooling of radioactive ion beams in a Penning trap is an essential component of the post-accelerator REX-ISOLDE at CERN. Prior to their charge-breeding and acceleration, ions from the on-line mass separator ISOLDE are accumulated, cooled and bunched with REXTRAP. This beam preparation provides short ion pulses with low emittance, key ingredient for a high efficiency of REX-ISOLDE. Two different cooling techniques have been investigated with REXTRAP. Both rely on the use of a buffer gas as the coolant but differ in the way the transversal compression of the stored ion cloud is achieved. Sideband cooling with a light buffer gas as coolant is the standard technique used at REXTRAP so …
Extension of Penning-trap mass measurements to very short-lived nuclides
2000
Abstract Mass measurements on 33,34,42,43 Ar have been performed at the ISOLTRAP spectrometer. An accuracy of δm ≈4 keV has been achieved for all measured isotopes. With 33 Ar it is the first time that a nuclide with a half-life shorter than one second has been investigated using a Penning trap. This became possible due to the recently installed linear radio-frequency ion-trap system and an improved, faster measurement cycle.
Towards a magnetic field stabilization at ISOLTRAP for high-accuracy mass measurements on exotic nuclides
2008
Abstract The field stability of a mass spectrometer plays a crucial role in the accuracy of mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of fluctuations are temperature variations in the vicinity of the trap and pressure changes in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the temperature and pressure fluctuations by at least an order of magnitude down to Δ T ≈ ± 5 mK and Δ p ≈ ± 5 Pa has been achieved, which corresponds to a relative magn…
Direct mass measurements of neutron-deficient xenon isotopes with the ISOLTRAP mass spectrometer
2000
Abstract The masses of Xe isotopes with 124⩾ A ⩾114 have been measured using the ISOLTRAP spectrometer at the on-line mass separator ISOLDE/CERN. A mass resolving power of 500 000 was chosen resulting in an accuracy of δm ≈12 keV for all isotopes investigated. Conflicts with existing mass data of several standard deviations were found.
PIPERADE: A double Penning trap for mass separation and mass spectrometry at DESIR/SPIRAL2
2021
International audience; A double Penning trap is being commissioned at CENBG Bordeaux for the future DESIR/SPIRAL2 facility of GANIL. The setup is designed to perform both high-resolution mass separation of the ion beam for trap-assisted spectroscopy, and high-accuracy mass spectrometry of short-lived nuclides. In this paper, the technical details of the new device are described. First offline tests with the purification trap are also presented, showing a mass resolving power of about 105.
Continuous Stern–Gerlach effect and the magnetic moment of the antiproton
2004
Abstract The measurement of the magnetic moment (or g-factor ) of the antiproton and of the proton is a sensitive test of CPT invariance. We discuss the possibility of applying the continuous Stern–Gerlach effect to detect quantum jumps between the two spin states (spin up and spin down) of the antiproton. The measurement will be performed on a single antiproton stored in a Penning trap. The g -factor of the antiproton is determined by measuring its cyclotron frequency and its spin precession frequency in the magnetic field of the trap. With the double Penning trap method the g -factor of the antiproton can be determined with an accuracy of 1 ppb.
JYFLTRAP: a cylindrical Penning trap for isobaric beam purification at IGISOL
2004
Abstract A Penning trap has been installed for isobaric beam purification at the IGISOL-facility at the University of Jyvaskyla. In this paper, the technical details of this new device together with results of the first tests are presented. The mass resolving power, depending on the excitation parameters and the ion species, can be as high as 145 000 and the total transmission has been determined to be 17%. In addition, it is shown that with this experimental setup it is possible to measure atomic masses up to A=120 with accuracies of approximately 50 keV .