Trap-assisted decay spectroscopy with ISOLTRAP

B. BlankDennis NeidherrKlaus BlaumJ. StanjaD. LunneyL. M. FraileF. HerfurthAlexander HerlertM. BreitenfeldtSusanne KreimKai ZuberE. Minaya-ramirezCh. BorgmannMarco RosenbuschLutz SchweikhardSebastian GeorgeAlejandro AlgoraCh. BöhmS. NaimiB. RubioD. BeckMagdalena KowalskaMagdalena KowalskaJ. Agramunt

subject

PhysicsNuclear and High Energy PhysicsRadionuclideStudies at ISOL-type facilitiesPenning trap mass spectrometers010308 nuclear & particles physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Trap (plumbing)Mass spectrometry01 natural sciencesISOLTRAPIonNuclear physicsTrap-assisted decay spectroscopy0103 physical sciencesIsobaric processNuclideNuclear Experiment010306 general physicsSpectroscopyInstrumentation

description

Penning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectroscopy has been coupled to the ISOLTRAP mass spectrometer at ISOLDE/CERN. The results from studies with stable and radioactive ions show that the setup can be used to perform decay studies on purified short-lived nuclides and to assist mass measurements. (C) 2012 Elsevier B.V. All rights reserved.

10.1016/j.nima.2012.04.059http://hdl.handle.net/20.500.12278/121202