Search results for "Trigger"
showing 10 items of 141 documents
Signaling pathways of the TREM-1- and TLR4-mediated neutrophil oxidative burst.
2008
The triggering receptor expressed on myeloid cells 1 (TREM-1) is involved in the innate inflammatory response to microbial infections. Activation and expression of TREM-1 by polymorphonuclear neutrophils (PMN) occurs in concert with Toll-like receptors (TLR) such as TLR4 for bacterial lipopolysaccharide. However, it is currently unclear how this is mediated on a molecular level. Using pharmacological inhibitors and Western blot analysis we demonstrate that phosphatidyl inositide 3-kinase, phospholipase C and the mitogen-activated kinase p38MAPK are essential for the TREM-1- and TLR4-induced oxidative burst of human PMN. The activation of protein kinase B and extracellular signal-related kin…
A pH-triggered bistable copper(II) metallacycle as a reversible emulsion switch for biphasic processes.
2013
A unique bistable copper-metallacyclic complex is used as an elegant molecular switch for the reversible formation of emulsions by simple pH variation. This switch may have several exciting applications in biphasic processes such as catalysis and separation science technologies.
Algorithms for the ROD DSP of the ATLAS Hadronic Tile Calorimeter
2007
In this paper we present the performance of two algorithms currently running in the Tile Calorimeter Read-Out Driver boards for the commissioning of ATLAS. The first algorithm presented is the so called Optimal Filtering. It reconstructs the deposited energy in the Tile Calorimeter and the arrival time of the data. The second algorithm is the MTag which tags low transverse momentum muons that may escape the ATLAS muon spectrometer first level trigger. Comparisons between online (inside the Read-Out Drivers) and offline implementations are done with an agreement around 99% for the reconstruction of the amplitude using the Optimal Filtering algorithm and a coincidende of 93% between the offli…
Effectiveness of Physical Therapy in Patients with Tension-type Headache: Literature Review
2014
Background: Tension-type headache (TTH) is a disease with a great incidence on quality of life and with a significant socioeconomic impact. Objectives: The aim of this review is to determine the effectiveness of physical therapy by using manual therapy (MT) for the relief of TTH. Data sources: A review was done identifying randomized controlled trials through searches in MEDLINE, PEDro, Cochrane and CINAHL (January 2002 – April 2012). Study selection: English-language studies, with adult patients and number of subjects not under 11, diagnosed with episodic tension-type headache (ETTH) and chronic tension-type headache (CTTH) were included. Data extraction: Initial search was undertaken with…
Using synchrotrons and XFELs for time-resolved X-ray crystallography and solution scattering experiments on biomolecules
2015
International audience; Time-resolved structural information is key to understand the mechanism of biological processes, such as catalysis and signalling. Recent developments in X-ray sources as well as data collection and analysis methods are making routine time-resolved X-ray crystallography and solution scattering experiments a real possibility for structural biologists. Here we review the information that can be obtained from these techniques and discuss the considerations that must be taken into account when designing a time-resolved experiment.
New-onset headache following COVID-19: An Italian multicentre case series
2023
Objective: To describe the characteristics of patients with new-onset headache following SARS-CoV-2 infection. Background: SARS-CoV-2 infection leads to several neurological manifestations, and headache is a frequent and disabling symptom, both exacerbating pre-existing headache syndromes and causing new-onset ones. Methods: Patients with new-onset headache after SARS-CoV-2 infection with consent to participate were included, while those ones with previous headaches were excluded. The temporal latency of headache after infection, pain characteristics, and concomitant symptoms were analysed. Moreover, the efficacy of acute and preventive medications was explored. Results: Eleven females (med…
Deployment of the ATLAS High-Level Trigger
2006
The ATLAS combined test beam in the second half of 2004 saw the first deployment of the ATLAS High-Level Trigger (HLT). The next steps are deployment on the pre-series farms in the experimental area during 2005, commissioning and cosmics tests with the full detector in 2006 and collisions in 2007. This paper reviews the experience gained in the test beam, describes the current status and discusses the further enhancements to be made. We address issues related to the dataflow, integration of selection algorithms, testing, software distribution, installation and improvements.
Auto-Adaptive Trigger and Pulse Extraction for Digital Processing in Nuclear Instrumentation
2015
International audience; This paper presents a novel auto-adaptive method for pulse triggering and extraction. Pulse triggering uses a threshold that must be placed as close as possible to the noise level. We do this by means of an adaptive threshold level based on real-time noise level estimation. A dynamic estimation of the pulse length is also used for pulse selection. The proposed approach is largely insensitive to noise and enables autonomous extraction of pulses regardless of their shape, height or length. The proposed approach can be used with numerous types of detectors from an analog-to-digital converter, and can be used in conjunction with various pulse processing techniques such a…
Characterization of a neutron-beta counting system with beta-delayed neutron emitters
2016
Abstract A new detection system for the measurement of beta-delayed neutron emission probabilities has been characterized using fission products with well known β-delayed neutron emission properties. The setup consists of BELEN-20, a 4π neutron counter with twenty 3He proportional tubes arranged inside a large polyethylene neutron moderator, a thin Si detector for β counting and a self-triggering digital data acquisition system. The use of delayed-neutron precursors with different neutron emission windows allowed the study of the effect of energy dependency on neutron, β and β–neutron rates. The observed effect is well reproduced by Monte Carlo simulations. The impact of this dependency on …
Implementation and performance of the third level muon trigger of the ATLAS experiment at LHC
2006
The trigger system of the ATLAS experiment at the LHC aims at a high selectivity in order to keep the full physics potential while reducing the 40 MHz initial event rate imposed by the LHC bunch crossing down to /spl sim/100 Hz, as required by the data acquisition system. Algorithms working in the final stage of the trigger environment (Event Filter) are implemented to run both in a "wrapped" mode (reconstructing tracks in the entire Muon Spectrometer) and in a "seeded" mode (according to a dedicated strategy that performs pattern recognition only in regions of the detector where trigger hypotheses have been produced at earlier stages). The working principles of the offline muon reconstruct…