Search results for "Tripping"
showing 10 items of 66 documents
Identification of inorganic pigments from paintings and polychromed sculptures immobilized into polymer film electrodes by stripping differential pul…
2000
Abstract Inorganic pigments in paintings and polychromed sculptures are studied by cyclic voltammetry and differential pulse stripping voltammetry using micro-sample coatings in Paraloid B72-film modified electrodes. Characteristic cathodic and anodic differential pulse profiles were obtained in the +0.4 to −1.0 V vs. SCE potential range for different cadmium, copper, lead, mercury and zinc pigments used in traditional colour palettes. Under optimized conditions, excellent reproducibility was obtained. Microsamples extracted from polychromed sculptures, wall paintings, canvas paintings, panel paintings and altarpieces from Spain, Ethiopia and Italy from the 12th to the 20th centuries have b…
Formation and Stability of Cadmium(II)/Phytate Complexes by Different Electrochemical Techniques. Critical Analysis of Results
2010
In the present work the stability constants of various cadmium(II)/phytate (Phy) species were determined at T = 298.15 K in NaNO3(aq) at I = 0.1 mol·L−1 by DP-ASV (Differential Pulse Anodic Stripping Voltammetry) and by potentiometric titrations using an ISE-Cd2+. Cyclic voltammograms were also recorded to check the electrochemical behavior of cadmium in the presence of phytate. The results were analyzed together with previous data determined by ISE-H+ measurements. Data obtained were used to provide an exhaustive speciation scheme for the phytate/cadmium(II) system at different conditions, as well as a comprehensive representation of the binding ability of phytate toward cadmium(II). Diffe…
Recent Approaches for Chemical Speciation and Analysis by Electrospray Ionization (ESI) Mass Spectrometry
2021
In these latest years, the chemical speciation of several species has been increasingly monitored and investigated by means of electrospray ionization mass spectrometry (ES-MS). This soft ionization technique is capable to gently take into the gas phase metal-ligand complexes and gather a wealth of information on their energetics, shape, and fragmentation pathways. For this reason, this technique is frequently chosen in a synergistic approach to investigate competitive ligand exchange-adsorptive other ways analyzed by cathodic stripping voltammetry (CLE-ACSV). ESI-MS analyses require a careful experimental design as they may be impacted by instrumental artifacts such as ESI adduct formation…
Fully aerobic bioscrubber for the desulfurization of H2S-rich biogas
2019
Abstract A fully aerobic bioscrubber for the desulfurization of H2S-rich biogas was developed in the present study by coupling an absorption column and a bubble column bioreactor. The bioscrubber treated H2S loading rates of 37, 59, and 100 g S mliquid−3 h−1 at gas residence times of 6.6, 4.1 and 2.4 min in the absorption column, respectively. Stable H2S removal efficiencies above 80% were recorded at all the conditions tested. The bioscrubber was robust towards short- and long-term operation shutdowns (5 and 18 days), the H2S removal performance being recovered after few hours. The aerated bubble column bioreactor was operated at slightly alkaline conditions (pH 8 ± 0.5), which prevented H…
Prefix Stripping Re-Re-Revisited: MEG Investigations of Morphological Decomposition and Recomposition
2019
We revisit a long-standing question in the psycholinguistic and neurolinguistic literature on comprehending morphologically complex words: are prefixes and suffixes processed using the same cognitive mechanisms? Recent work using Magnetoencephalography (MEG) to uncover the dynamic temporal and spatial responses evoked by visually presented complex suffixed single words provide us with a comprehensive picture of morphological processing in the brain, from early, form-based decomposition, through lexical access, grammatically constrained recomposition, and semantic interpretation. In the present study, we find that MEG responses to prefixed words reveal interesting early differences in the la…
Pb(II) adsorption by a novel activated carbon - alginate composite material. A kinetic and equilibrium study.
2016
The adsorption capacity of an activated carbon – calcium alginate composite material (ACAA-Ca) has been tested with the aim of developing a new and more efficient adsorbent material to remove Pb(II) ion from aqueous solution. The study was carried out at pH = 5, in NaCl medium and in the ionic strength range 0.1–0.75 mol L−1. Differential Pulse Anodic Stripping Voltammetry (DP-ASV) technique was used to check the amount of Pb(II) ion removed during kinetic and equilibrium experiments. Different kinetic (pseudo first order, pseudo second order and Vermuelen) and equilibrium (Langmuir and Freundlich) models were used to fit experimental data, and were statistically compared. Calcium alginate …
Automatic skull stripping in MRI based on morphological filters and fuzzy c-means segmentation
2012
In this paper a new automatic skull stripping method for T1-weighted MR image of human brain is presented. Skull stripping is a process that allows to separate the brain from the rest of tissues. The proposed method is based on a 2D brain extraction making use of fuzzy c-means segmentation and morphological operators applied on transversal slices. The approach is extended to the 3D case, taking into account the result obtained from the preceding slice to solve the organ splitting problem. The proposed approach is compared with BET (Brain Extraction Tool) implemented in MRIcro software.
Vanadium and molybdenum concentrations in particulate from Palermo (Italy): analytical methods using voltammetry
2014
The main purpose of this work was to develop a reliable method for the determination of vanadium (V) and molybdenum (Mo) in atmosphere particles or aerosols because they can not be readily measured using conventional techniques. For this research, 30 particulate samples were collected from five different stations located at Palermo, Italy. We used the catalytic adsorptive stripping voltammetry and differential pulsed voltammetry to measure Vand Mo in atmospheric particulate, respectively. The represented method includes advantages of high sensitivity, high selectivity, simplicity, reproducibility, speed and low costs. The quantification limits for V and Mo are, respectively, 0.57 and 0.80 n…
Voltammetric behavior and assay of the contraceptive drug levonorgestrel in bulk, tablets, and human serum at a mercury electrode.
2004
The cyclic voltammograms of levonorgestrel (LNG) in Britton-Robinson buffers of pH 2-11 at the hanging mercury drop electrode showed a single two-electron irreversible cathodic peak over the whole pH range. This peak may be attributed to the reduction of the 3-keto-delta-4-group in the A-ring of the LNG molecule. The interfacial adsorptive character of levonorgestrel onto the surface of the hanging mercury drop electrode was identified by means of both cyclic voltammetry and chronocoulometry techniques. A simple, sensitive, and selective square-wave adsorptive cathodic stripping voltammetric procedure was developed for the quantitation of levonorgestrel. Under the optimized operational cond…
Screening of physical–chemical methods for removal of organic material, nitrogen and toxicity from low strength landfill leachates
2002
Physical-chemical methods have been suggested for the treatment of low strength municipal landfill leachates. Therefore, applicability of nanofiltration and air stripping were screened in laboratory-scale for the removal of organic matter, ammonia, and toxicity from low strength leachates (NH4-N 74-220 mg/l, chemical oxygen demand (COD) 190-920 mg O2/l, EC50 = 2-17% for Raphidocelis subcapitata). Ozonation was studied as well, but with the emphasis on enhancing biodegradability of leachates. Nanofiltration (25 degrees C) removed 52-66% of COD and 27-50% of ammonia, the latter indicating that ammonia may in part have been present as ammonium salt complexes. Biological pretreatment enhanced t…