Search results for "Tripping"

showing 6 items of 66 documents

Determination of toxic elements by cathodic-stripping-voltammetry

1981

The DPCSV determination of arsenic, selenium and tellurium in the sub-ng/ml range is discussed. After electrolytic deposition of the elements as intermetallic compounds with copper on the electrode surface, the determination is carried out by cathodic stripping. The simultaneous determination of selenium and tellurium or of selenium and arsenic is possible. Problems which occur in the application of these methods are discussed.

inorganic chemicalsStripping (chemistry)Inorganic chemistryIntermetallicfood and beverageschemistry.chemical_elementCopperAnalytical ChemistryCathodic protectionchemistryCathodic stripping voltammetryTelluriumArsenicSeleniumMikrochimica Acta
researchProduct

Irregularity of the posterior corneal surface during applanation using a curved femtosecond laser interface and microkeratome cutting head.

2012

PURPOSE: To evaluate the irregularity of the posterior corneal surface and intrastromal dissection during the preparation of donor tissue for Descemet stripping automated endothelial keratoplasty (DSAEK) using a curved interface femtosecond laser and microkeratome. METHODS: Sixteen human donor corneas unsuitable for transplantation were divided into two groups: a femtosecond (FS) laser group (n=7) using the VisuMax femtosecond laser (Carl Zeiss Meditec) and a microkeratome group (n=9) using the Amadeus II microkeratome (Ziemer Ophthalmic Group). The corneas were fixed on artificial anterior chambers. Horizontal cross-sections were obtained using spectral-domain optical coherence tomography…

medicine.medical_specialtyMaterials sciencegenetic structuresSurface PropertiesCorneal Stromalaw.inventionOpticsOptical coherence tomographylawMicrokeratomeOphthalmologyCorneamedicineHumansCorneal surfaceAged 80 and overmedicine.diagnostic_testbusiness.industryEndothelium CornealDescemet stripping automated endothelial keratoplastyLasereye diseasesTissue DonorsTransplantationOphthalmologymedicine.anatomical_structureFemtosecondSurgeryLasers Excimersense organsbusinessDescemet Stripping Endothelial KeratoplastyTomography Optical CoherenceJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Bilateral Ultrathin Descemet’s Stripping Automated Endothelial Keratoplasty vs. Bilateral Penetrating Keratoplasty in Fuchs’ Dystrophy: Corneal Highe…

2021

Background and Objectives: The objective of this paper is to compare the visual outcomes and quality of life (QoL) after bilateral ultrathin Descemet’s stripping automated endothelial keratoplasty (UT-DSAEK) with bilateral penetrating keratoplasty (PK) for Fuchs’ endothelial dystrophy (FED). Materials and Methods: Retrospective comparative cohort study, including 11 patients with FED who underwent bilateral PK and 13 patients with FED who underwent bilateral UT-DSAEK. All patients were already pseudophakic or had undergone a combined cataract procedure. The main outcomes were corrected distance visual acuity (CDVA) corneal higher-order aberrations (HOAs), contrast sensitivity (CS) and quali…

medicine.medical_specialtyMedicine (General)Visual acuityDistance visual acuitygenetic structuresvisual acuitymedia_common.quotation_subjectmedicine.medical_treatmentFuchs' dystrophyArticleCohort StudiesR5-920Quality of lifeOphthalmologyhigher-order aberrationmedicineContrast (vision)HumansEye surgerymedia_commonRetrospective Studiescontrast sensitivityhigher-order aberrationsbusiness.industryFuchs' Endothelial DystrophyDystrophybilateral penetrating keratoplastyGeneral Medicinemedicine.diseasebilateral ultrathin DSAEKeye diseasesAberrations of the eyebilateral ultrathin DSAEK; bilateral penetrating keratoplasty; visual acuity; contrast sensitivity; higher-order aberrations; quality of lifequality of lifevisual acuity.medicine.symptombusinessDescemet Stripping Endothelial KeratoplastyKeratoplasty PenetratingMedicina
researchProduct

ONE-TROCAR VIDEO-ASSISTED STRIPPING TECHNIQUE FOR USE IN THE TREATMENT OF LARGE OVARIAN CYSTS IN INFANTS

2010

Abstract Background Management of ovarian cysts in infants is controversial; it can be conservative or surgical, and the management is determined by the cyst's size and sonographic features. Methods A surgical approach using a 10-mm umbilically placed operative laparoscope was taken in 3 female infants with antenatally diagnosed large, simple ovarian cysts. The contents of the cysts were partially aspirated and the cyst walls were stripped off the remaining ovarian parenchyma. No intraoperative or postoperative complications were recorded. Conclusions The one-trocar video-assisted stripping technique for large ovarian cysts in infants appears to be an ovarian-tissue-preserving procedure, an…

medicine.medical_specialtyendocrine system diseasesScarsVideo-Assisted SurgeryUltrasonography PrenatalMini invasive surgeryparasitic diseasesmedicineHumansCystVideo assistedLaparoscopyvideo-assistedSurgical approachOvarian cystmedicine.diagnostic_testone-trocarbusiness.industrySettore MED/20 - Chirurgia Pediatrica E InfantileInfantObstetrics and GynecologystrippingGeneral MedicineOvarian cyst; stripping; one-trocar; video-assistedmedicine.diseaseSurgeryOvarian CystsPediatrics Perinatology and Child HealthOvarian cystFemaleLaparoscopymedicine.symptombusiness
researchProduct

Laser fluence, repetition rate and pulse duration effects on paint ablation

2006

Abstract The efficiency (mm3/(J pulse)) of laser ablation of paint was investigated with nanosecond pulsed Nd:YAG lasers (λ = 532 nm) as a function of the following laser beam parameters: pulse repetition rate (1–10,000 Hz), laser fluence (0.1–5 J/cm2) and pulse duration (5 ns and 100 ns). In our study, the best ablation efficiency (η ≅ 0.3 mm3/J) was obtained with the highest repetition rate (10 kHz) at the fluence F = 1.5 J/cm2. This ablation efficiency can be associated with heat accumulation at high repetition rate, which leads to the ablation threshold decrease. Despite the low thermal diffusivity and the low optical absorption of the paint (thermal confinement regime), the ablation th…

thermal confinement regimeMaterials sciencePACS: 81.65 Cf; 42.62 Cf; 61.82 Msmedicine.medical_treatmentGeneral Physics and Astronomy02 engineering and technology01 natural sciencesFluencelaw.invention010309 opticsOpticslaw0103 physical sciencesmedicineAbsorption (electromagnetic radiation)Laser ablationPulse (signal processing)business.industryrepetition ratePulse duration[CHIM.MATE]Chemical Sciences/Material chemistrySurfaces and InterfacesGeneral ChemistryNanosecond021001 nanoscience & nanotechnologyCondensed Matter PhysicsAblationLaserpaint strippingLaser ablationSurfaces Coatings and Filmspulse duration[ CHIM.MATE ] Chemical Sciences/Material chemistryOptoelectronics0210 nano-technologybusinessApplied Surface Science
researchProduct

Micro-determination of dithiocarbamates in pesticide formulations using voltammetry

2013

Abstract The purpose of this work was to develop a reliable method for the micro-determination of dithiocarbamates (mancozeb, maneb, propineb, nabam, Na(CH3)2DTC, zineb, ziram, ferbam and thiram) in pesticide formulations for agriculture using adsorptive stripping voltammetry (AdSV). The accuracy of analytical method was valued by analyzing simulate formulation samples prepared by us with known amounts of active ingredients. In addition, the applicability of the AdSV procedure for the analysis of DTCs and EBDTCs in micro-samples was evaluated by estimating its recoveries from spiked commercial formulate samples. The accuracy, valuated as recovery percentage ranged between 85% and 97%. The p…

voltammetryZiramChromatographyThiramManebformulationPesticideSettore CHIM/12 - Chimica Dell'Ambiente E Dei Beni CulturaliAnalytical Chemistrydithiocarbamatechemistry.chemical_compoundchemistryZinebAdsorptive stripping voltammetrySettore CHIM/01 - Chimica AnaliticaMancozebVoltammetryMicro determinationpesticideSpectroscopyMicrochemical Journal
researchProduct