Search results for "UI"
showing 10 items of 43725 documents
Quartz resonators for penning traps toward mass spectrometry on the heaviest ions
2020
We report on cyclotron frequency measurements on trapped 206,207Pb+ ions by means of the non-destructive Fourier-transform ion-cyclotron-resonance technique at room temperature. In a proof-of-principle experiment using a quartz crystal instead of a coil as a resonator, we have alternately carried out cyclotron frequency measurements for 206Pb+ and 207Pb+ with the sideband coupling method to obtain 21 cyclotron-frequency ratios with a statistical uncertainty of 6 × 10−7. The mean frequency ratio R¯ deviates by about 2σ from the value deduced from the masses reported in the latest Atomic Mass Evaluation. We anticipate that this shift is due to the ion–ion interaction between the simultaneousl…
XUV diagnostic to monitor H-like emission from B, C, N, and O for the W7-X stellarator
2019
The “C/O Monitor” system for the Wendelstein 7-X (W7-X) stellarator is a dedicated spectrometer with high throughput and high time resolution (order of 1 ms) for fast monitoring of content of low-Z impurities in the plasma. The observed spectral lines are fixed to Lyman-α lines of H-like atoms of carbon (3.4 nm), oxygen (1.9 nm), nitrogen (2.5 nm), and boron (4.9 nm). The quality of the wall condition will be monitored by the measurements of oxygen being released from the walls during the experiments. The strong presence of carbon is an indication for enhanced plasma-wall interaction or overload of plasma facing components. The presence of nitrogen (together with oxygen) may indicate a poss…
Choice of the detectors for light impurities plasma studies at W7-X using ‘CO Monitor’ system
2019
Abstarct The ‘CO Monitor’ is a new spectrometer system dedicated for the continuous measurements of line intensities of carbon, oxygen, boron and nitrogen at the fusion plasma experiment Wendelstein 7-X (W7-X). Its main purpose is to deliver constant information about indicated elements with high time resolution (better than 1 ms), but low spatial resolution since the line shapes are not going to be investigated. The system consists of four independent channels, each equipped with dispersive element dedicated for measurement of selected line of interest. In order to perform the highest efficiency of the ‘CO Monitor’ system, it is essential to choose the proper detector type for this task. T…
Correlations between density distributions, optical spectra, and ion species in a hydrogen plasma (invited)
2016
An experimental study of plasma distributions in a 2.45 GHz hydrogen discharge operated at 100 Hz repetition rate is presented. Ultrafast photography, time integrated visible light emission spectra, time resolved Balmer-alpha emission, time resolved Fulcher Band emission, ion species mass spectra, and time resolved ion species fraction measurements have been implemented as diagnostic tools in a broad range of plasma conditions. Results of plasma distributions and optical emissions correlated with H + , H + 2 , and H + 3 ion currents by using a Wien filter system with optical observation capability are reported. The magnetic field distribution and strength is found as the most critical facto…
Plasma instabilities of a charge breeder ECRIS
2017
International audience; Experimental observation of plasma instabilities in a charge breeder electron cyclotron resonance ion source (CB-ECRIS) is reported. It is demonstrated that the injection of 133Cs+ or 85Rb+ ion beam into the oxygen discharge of the CB-ECRIS can trigger electron cyclotron instabilities, which restricts the parameter space available for the optimization of the charge breeding efficiency. It is concluded that the transition from a stable to unstable plasma regime is caused by gradual accumulation and ionization of Cs/Rb and simultaneous change of the discharge parameters in 10–100 ms time scale, not by a prompt interaction between the incident ion beam and the ECRIS pla…
The role of seed electrons on the plasma breakdown and preglow of electron cyclotron resonance ion source
2009
The 14 GHz Electron Cyclotron Resonance Ion Source at University of Jyväskylä, Department of Physics (JYFL) has been operated in pulsed mode in order to study the plasma breakdown and preglow effect. It was observed that the plasma breakdown time and preglow characteristics are affected by seed electrons provided by a continuous low power microwave signal at secondary frequency. Sustaining low density plasma during the off-period of high power microwave pulses at the primary frequency shifts the charge state distribution of the preglow transient toward higher charge states. This could be exploited for applications requiring fast and efficient ionization of radioactive elements as proposed f…
SiC MOSFET vs SiC/Si Cascode short circuit robustness benchmark
2019
Abstract Nowadays, MOSFET SiC semiconductors short circuit capability is a key issue. SiC/Si Cascodes are compound semiconductors that, in some aspects, show a similar MOSFET behaviour. No interlayer dielectric insulation suggests, in theory, Cascode JFETs as more robust devices. The purpose of this paper is to compare the drift and degradation of two commercial devices static parameters by exposing them to different levels of repetitive 1.5 μs short-circuit campaigns at 85% of its breakdown voltage. Short-circuit time has been set experimentally, and longer times result in catastrophic failure of MOSFET devices due to over self-heating. For this purpose, pre- and post-test short circuit ch…
A new Collinear Apparatus for Laser Spectroscopy and Applied Science (COALA).
2020
We present a new collinear laser spectroscopy setup that has been designed to overcome systematic uncertainty limits arising from high-voltage and frequency measurements, beam superposition, and collisions with residual gas that are present in other installations utilizing this technique. The applied methods and experimental realizations are described, including an active stabilization of the ion-source potential, new types of ion sources that have not been used for collinear laser spectroscopy so far, dedicated installations for pump-and-probe measurements, and a versatile laser system referenced to a frequency comb. The advanced setup enables us to routinely determine transition frequenci…
Guiding and splitting Lamb waves in coupled-resonator elastic waveguides
2018
Abstract We investigate experimentally Lamb wave propagation in coupled-resonator elastic waveguides (CREWs) formed by a chain of cavities in a two-dimensional phononic crystal slab with cross holes. Wide complete bandgaps, extending from 53 to 88 kHz, are first measured in a finite phononic crystal slab sample. A straight waveguide and a wave splitting circuit with 90° bends are then designed, fabricated and measured. Elastic Lamb waves are excited by a piezoelectric patch attached to one side of the phononic slab and detected using a scanning vibrometer. Strongly confined guiding and splitting at waveguide junctions are clearly observed for several guided waves. Numerical simulations are …
Determination of refractive index of submicron-thick films using resonance shift in a four-layer slab waveguide
2017
The measurement of refractive index of very thin films at the order of ten to hundred nanometers is cumbersome and usually requires employing sophisticated techniques such as the spectral ellipsometry. In this paper we describe a simple contact method for measuring the refractive index of thin films. Here we have used the prism-coupling technique for characterizing samples prepared as four-layer slab waveguides. The waveguide resonance condition can be calculated by solving simple analytic transcendental equations for the slab waveguide. Then the captured mode position as a function of cladding thickness is used for probing the refractive index of cladding layer. We used indium-tin-oxide la…