Search results for "UI"

showing 10 items of 43725 documents

First experiments on applying the gasdynamic ECR ion source for negative hydrogen ion production

2017

This article has no abstract. peerReviewed

010302 applied physicsHydrogen ionta114ChemistryPhysicsQC1-99901 natural sciencesIon source010305 fluids & plasmasECR ion sourcesChemical physics0103 physical sciencesAtomic physicshydrogen ionsEPJ Web of Conferences
researchProduct

The helicoidal magnetic generator

2016

Recently helicoidal generator for the exploitation of sea wave energy has been proposed. This device can convert both the vertical and rotational movement of seawaves. The electrical energy generated by such a device must be converted and conditioned in order to match the instantaneous utility requirements and a power link from the sea to an interconnection is needed. In this paper, the authors propose a mathematical model of this device and preliminarily present a prototype of the machine.

010302 applied physicsInterconnectionEngineeringbusiness.industryLinear asynchronous generatorElectric potential energy05 social sciencesElectrical engineeringOcean EngineeringPermanent magnet synchronous generatorElectric machineSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciInductorOceanography01 natural sciencesPower (physics)Generator (circuit theory)Electromagnetic coil0502 economics and business0103 physical sciencesbusinessInstrumentation050203 business & managementEnergy (signal processing)Sea waves energy
researchProduct

Injected 1+ ion beam as a diagnostics tool of charge breeder ECR ion source plasmas

2015

International audience; Charge breeder electron cyclotron resonance ion sources (CB-ECRIS) are used as 1+  →n+  charge multiplication devices of post-accelerated radioactive ion beams. The charge breeding process involves thermalization of the injected 1+  ions with the plasma ions in ion–ion collisions, subsequent ionization by electron impact and extraction of the n+  ions. Charge breeding experiments of 85Rb and 133Cs ion beams with the 14.5 GHz PHOENIX CB-ECRIS operating with oxygen gas demonstrate the plasma diagnostics capabilities of the 1+  injection method. Two populations can be distinguished in the m/q-spectrum of the extracted ion beams, the low (1+  and 2+) charge states repres…

010302 applied physicsIon beamAmbipolar diffusionChemistry[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]ElectronPlasmaCondensed Matter Physics01 natural sciences7. Clean energyIon source010305 fluids & plasmasIonPhysics::Plasma PhysicsIonization0103 physical sciencesAtomic physicsElectron ionization
researchProduct

Binocular function measures as predictors of user performance in stereoscopic augmented reality

2021

Inconsistency between the binocular and focus cues in stereoscopic augmented reality overburdens the visual system leading to its stress. However, a high individual variability of tolerance for visual stress makes it difficult to predict and generalize the user gain associated with the implementation of alternative visualization technologies. In this study, we investigated the relationship between the binocular function and perceptual judgments in augmented reality. We assessed the task completion time and accuracy of perceptual distance matching depending on the consistency of binocular and focus cues in the stereoscopic environment of augmented reality. The head-mounted display was driven…

010302 applied physicsMatching (statistics)genetic structuresbusiness.industryComputer sciencemedia_common.quotation_subjectStereoscopy01 natural scienceseye diseaseslaw.inventionVisualization010309 opticslawPerception0103 physical sciencesStress (linguistics)Contrast (vision)Computer visionAugmented realityArtificial intelligencebusinessFocus (optics)media_common
researchProduct

Influence of magnetization on the applied magnetic field in various AMR regenerators

2017

International audience; The aim of this work is to assess the influence of a magnetic sample on the applied magnetic field inside the air gap of a magnetic circuit. Different magnetic sources including an electromagnet, a permanent magnet in a soft ferromagnetic toroidal yoke, as well as 2D and 3D Halbach cylinders are considered, using a numerical model. Gadolinium is chosen as magnetic material for the sample, due to its strong magnetocaloric properties and its wide use in magnetic refrigeration prototypes. We find that using uniform theoretical demagnetizing factors for cylinders or spheres results in a deviation of less than 2% in the calculation of internal magnetic fields at temperatu…

010302 applied physicsMaterials scienceElectromagnetMagnetic domainMagnetic energyCondensed matter physics[SPI.NRJ]Engineering Sciences [physics]/Electric powerDemagnetizing fieldGeneral Physics and Astronomy02 engineering and technology021001 nanoscience & nanotechnology01 natural sciences[SPI.AUTO]Engineering Sciences [physics]/Automaticlaw.inventionCondensed Matter::Materials ScienceMagnetizationRemanencelaw0103 physical sciences[PHYS.MECA.THER]Physics [physics]/Mechanics [physics]/Thermics [physics.class-ph]Magnetic pressure[PHYS.MECA.MEFL]Physics [physics]/Mechanics [physics]/Fluid mechanics [physics.class-ph]Single domain0210 nano-technologyJournal of Applied Physics
researchProduct

A quartz amplifier for high-sensitivity Fourier-transform ion-cyclotron-resonance measurements with trapped ions

2019

Single-ion sensitivity is obtained in precision Penning-trap experiments devoted to light (anti)particles or ions with low mass-to-charge ratios, by adding an inductance coil to an amplifier connected to the trap, both operated at 4 K. However, single-ion sensitivity has not been reached on heavy singly or doubly charged ions. In this publication, we present a new system to reach this point, based on the use of a quartz crystal as an inductance, together with a newly developed broad-band (BB) amplifier. We detect the reduced-cyclotron frequency of 40Ca+ ions stored in a 7-tesla open-ring Penning trap. By comparing the detected electric signal obtained with the BB amplifier and the fluoresce…

010302 applied physicsMaterials scienceEquivalent series resistanceAmplifierPenning trap01 natural sciences7. Clean energySignalFourier transform ion cyclotron resonance010305 fluids & plasmasIonCrystal0103 physical sciencesAtomic physicsInstrumentationSensitivity (electronics)Review of Scientific Instruments
researchProduct

Photoelectron Emission from Metal Surfaces Induced by VUV-emission of Filament Driven Hydrogen Arc Discharge Plasma

2015

Photoelectron emission measurements have been performed using a filament-driven multi-cusp arc discharge volume production H^- ion source (LIISA). It has been found that photoelectron currents obtained with Al, Cu, Mo, Ta and stainless steel (SAE 304) are on the same order of magnitude. The photoelectron currents depend linearly on the discharge power. It is shown experimentally that photoelectron emission is significant only in the short wavelength range of hydrogen spectrum due to the energy dependence of the quantum efficiency. It is estimated from the measured data that the maximum photoelectron flux from plasma chamber walls is on the order of 1 A per kW of discharge power.

010302 applied physicsMaterials scienceHydrogenPhysics::Instrumentation and DetectorsFluxchemistry.chemical_elementFOS: Physical sciencesPlasma01 natural sciences7. Clean energyPhysics - Plasma PhysicsIon source010305 fluids & plasmasElectric arcPlasma Physics (physics.plasm-ph)chemistryPhysics::Plasma Physics0103 physical sciencesPhysics::Atomic and Molecular ClustersQuantum efficiencyPhysics::Atomic PhysicsAtomic physicsHydrogen spectral seriesOrder of magnitude
researchProduct

Operating a cesium sputter source in a pulsed mode

2020

A scheme is presented for pulsing of a cesium sputter negative ion source by periodically switching on and off the high voltage driving the sputtering process. We demonstrate how the pulsed ion beam can be used in combination with a pulsed laser (6 ns pulse length) that has a 10 Hz repetition rate to study the photodetachment process, where a negative ion is neutralized due to the absorption of a photon. In such experiments, where the ion beam is used only for a small fraction of the time, we show that the pulsed mode operation can increase the lifetime of a cathode by two orders of magnitude as compared with DC operation. We also investigate how the peak ion current compares with the ion c…

010302 applied physicsMaterials scienceIon beamPulse durationIon currentHigh voltage01 natural sciencesCathode010305 fluids & plasmasIonlaw.inventionPhysics::Plasma PhysicsSputteringlaw0103 physical sciencesAtomic physicsAbsorption (electromagnetic radiation)InstrumentationReview of Scientific Instruments
researchProduct

A new 18 GHz room temperature electron cyclotron resonance ion source for highly charged ion beams

2020

An innovative 18 GHz HIISI (Heavy Ion Ion Source Injector) room temperature Electron Cyclotron Resonance (ECR) ion source (ECRIS) has been designed and constructed at the Department of Physics, University of Jyväskylä (JYFL), for the nuclear physics program of the JYFL Accelerator Laboratory. The primary objective of HIISI is to increase the intensities of medium charge states (M/Q ≅ 5) by a factor of 10 in comparison with the JYFL 14 GHz ECRIS and to increase the maximum usable xenon charge state from 35+ to 44+ to serve the space electronics irradiation testing program. HIISI is equipped with a refrigerated permanent magnet hexapole and a noncylindrical plasma chamber to achieve very stro…

010302 applied physicsMaterials scienceIon beamsyklotronittutkimuslaitteetHighly charged ionchemistry.chemical_elementhiukkaskiihdyttimet01 natural sciences7. Clean energyIon sourceElectron cyclotron resonance010305 fluids & plasmasIonXenonchemistry0103 physical sciencesIrradiationAtomic physicsInstrumentationBeam (structure)
researchProduct

The effect of plasma instabilities on the background impurities in charge breeder ECRIS

2017

International audience; Experimental observations of plasma instabilities in the 14.5 GHz PHOENIX charge breeder ECRIS are summarized. It has been found that the injection of 133Cs+ or 85Rb+ into oxygen discharge of the CB-ECRIS can trigger electron cyclotron instabilities, which results to sputtering of the surfaces exposed to the plasma, followed by up to an order of magnitude increase of impurity currents in the extracted n+ charge state distribution. The transition from stable to unstable plasma regime is caused by gradual accumulation and ionization of Cs/Rb altering the discharge parameters in 10 - 100 ms time scale, not by a prompt interaction between the incident ion beam and the EC…

010302 applied physicsMaterials scienceIon beamta114syklotronit[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Buffer gasCyclotronPlasmaElectroncharge breederplasmafysiikka7. Clean energy01 natural sciences010305 fluids & plasmaslaw.inventionIonECRISSputteringlawIonization0103 physical sciencesAtomic physicsplasma (kaasut)plasma
researchProduct