Search results for "ULTRASONOGRAPHY"
showing 10 items of 930 documents
Ultrasound-guided fine-needle aspiration cytology in the early detection of melanoma metastases.
2000
BACKGROUND. The early detection and treatment of tumor recurrences in melanoma patients is dependent on reliable, sensitive, and specific techniques to verify suspected tumor metastases. As of now, fine-needle aspiration cytology (FNAC) has yet to establish itself in the routine follow-up of melanoma patients. METHODS. FNAC procedures were performed in melanoma patients with palpable tumors or nonpalpable, ultrasonically suspicious lesions. Cytodiagnostic evaluation of fine-needle samples obtained from suspicious lesions was performed morphologically. Findings were validated either by histopathologic diagnosis or prolonged clinical follow-up. RESULTS. The cytologic examination of 739 FNACs …
Efficacy of ultrasound B-scan compared with physical examination in follow-up of melanoma patients
2001
BACKGROUND The value of ultrasound B-scan for routine follow-up of melanoma patients still is not generally accepted. Therefore, the authors compared the efficacy of physical examination (PE) with ultrasound B-scan (UBS) for detection of regional tumor recurrence in melanoma patients. The aim of the current study was to evaluate whether early detection of metastases improves relapse-free and overall survival. METHODS For a period of 4 years, 829 consecutive melanoma patients were followed prospectively. Physical examination of 3011 patients and concomitant UBS of in-transit routes and regional lymph node basins were performed. Suspicious lesions were diagnosed by fine-needle aspiration cyto…
Volume flow in the common carotid artery does not decrease postprandially.
2003
Background and Purpose. A commonplace explanation for postprandial fatigue is the assumption of the redistribution of perfusion from the cerebral to the mesenterial territory. However, this assumption has never been scientifically proven. Methods. Because approximately 70% of the blood flow in the common carotid artery (CCA) is directed to the internal carotid artery, this vessel can be seen as a major brain-supplying artery. Flow volume in the CCA can be measured by color M-mode duplex sonography. The authors investigated the flow volume rate in 20 healthy volunteers before and after the intake of a high-energy meal. Heart rate, blood pressure, and expiratory CO2 were also measured at both…
Real-time, ultrasound-guided infraclavicular axillary vein cannulation for renal replacement therapy in the critical care unit—A prospective interven…
2015
Abstract Purpose The cannulation of the axillary vein for renal replacement therapy is a rarely performed procedure in the critical care unit. We defined the venipuncture and catheterization success rates and early mechanical complication rates of this technique in critical care patients with acute kidney injury. Materials and methods Twenty-nine mechanically ventilated patients with clinical indications for insertion of temporary hemodialysis catheters enrolled in a registered trial (NCT01919528) as a pilot cohort. We performed 29 real-time, ultrasound-guided infraclavicular axillary vein cannulation attempts for renal replacement therapy. We defined the venipuncture and catheterization su…
Behavior of fascicles and the myotendinous junction of human medial gastrocnemius following eccentric strength training
2009
This study is the first in which measurements of thickness, fascicle angle and length, and tendon elongation were combined to examine the impact of eccentric strength training on both muscle architecture and tendinous structures. Eighteen healthy male subjects were divided into an eccentric strength training group (n = 10) and a control group (n = 8). The training program consisted of 18 sessions of eccentric exercises over a 7-week period. All subjects were tested at baseline and after the last training session. Using ultrasound imaging, the fascicle angle and length and thickness of the medial gastrocnemius (MG) were analyzed at rest (i.e., theta(p), Fl(p), and t(p), respectively), at 50%…
Transcranial Doppler ultrasound study of the effects of nitrous oxide on cerebral autoregulation during neurosurgical anesthesia: a randomized contro…
2003
Object. Nitrous oxide has an adverse effect on cerebrovascular hemodynamics. Increased intracranial pressure, cerebral blood flow (CBF), cerebral metabolic rate of O2 (CMRO2), and reduced autoregulation indices have been reported, but their magnitudes are still being debated. This study was designed to evaluate the effect of N2O on CBF and autoregulatory indexes during N2O—sevoflurane anesthesia in a prospective randomized controlled series of patients. Methods. Two groups of 20 patients were studied on the basis of the use of N2O in the anesthetic gas mixture. The transient hyperemic response test, which relies on transcranial Doppler ultrasound techniques, was used to assess cerebral hemo…
Color-coded duplex ultrasonography of the origin of the vertebral artery: normal values of flow velocities.
2000
The introduction of color-coded duplex ultrasonography has improved the ease of performing ultrasound investigations of the vertebral arteries. So far, normal values of flow velocities have been reported only for the intertransverse region of the vertebral artery (V2 segments). Atherosclerotic disease at the origin of the vertebral arteries (V0 segment) is frequent and is one of the risk factors for vertebrobasilar ischemic disease. Normal values of flow velocities of the vertebral artery origin are needed to assess pathologic findings, such as vertebral artery origin stenosis or dissection. The aim of this study was to describe the normal flow velocities of vertebral artery origin (V0 segm…
Evaluation of regional haemodynamics and alterations of vascular wall of the lower limbs in hypertensive subjects
1995
This study was designed to analyse the relationship between arterial hypertension and changes in arterial blood flow and vascular wall damage of the lower limbs in hypertensive patients with various degrees of hypertension. Six hundred and fifty-four hypertensive patients (421 males and 233 females) aged 35 to 70 years and 88 healthy subjects (63 males and 25 females) aged 39 to 60 years were studied. Strain-gauge plethysmography of the lower limbs was used to calculate arterial calf blood flow (RF), arterial calf blood flow after post-ischaemic hyperaemia (PF), basal and minimal vascular resistances (BVR and MVR), time to reach peak flow (tPF), time until 50% reduction of peak flow (tT1/2)…
Echogenicity of the substantia nigra in relatives of patients with sporadic Parkinson’s disease
2003
Increased echogenicity of the substantia nigra (SN) on ultrasound is a typical sonographic finding in Parkinson's disease (PD). Sonographic signal intensity of the SN is related to tissue iron content with higher iron level being associated with increased echogenicity. Recent findings indicate that hyperechogenicity of the SN represents an important susceptibility factor for nigrostriatal degeneration. In this study we determined the prevalence of a characteristic ultrasound sign of Parkinson's disease in first-degree relatives of PD patients. Fourteen patients with sporadic PD and 58 of their relatives underwent neurological, neuropsychological, and ultrasound examination. In addition, fou…
Real-time spatial compound sonography of Achilles tendon in patients with heterozygous familial hypercholesterolaemia and normal physical examination
2007
This study was undertaken to assess the prevalence and ultrasound features of Achilles tendon xanthomas (ATX) in patients with heterozygous familial hypercholesterolemia (HFH) and normal physical examination studied with high-resolution ultrasonography (HRUS) and, secondarily, to evaluate the role of real-time spatial compound sonography (CS) in terms of image quality.Both Achilles tendons of 40 patients with HFH were studied with HRUS and CS. Two experienced radiologists evaluated by consensus the presence of ATX described as (1) tendon thickening and/or (2) focal hypoechoic areas and the quality of images obtained with the two techniques.Ten out of 80 tendons showed thickening (mean: 11.2…