Search results for "Ulna"
showing 10 items of 56 documents
Endoscopic carpal tunnel release: results with special consideration to possible complications.
2000
Single-portal endoscopic carpal tunnel release (Agee technique) was carried out in 148 patients. Of these, 100 were examined clinically and electrophysiologically 1 day before surgery and 1 and 3 months thereafter. Ten patients experienced transient ulnar neuropraxia and two patients complained postoperatively of intense pain in the middle and ring fingers. Three patients suffered residual symptoms. In one of these an incomplete release of the distal portion of the retinaculum flexorum was suspected and later confirmed by magnetic resonance imaging. Another patient had applied for pension due to problems associated with a vertebral fracture in addition to his carpal tunnel symptoms. A third…
Preoperative evaluation of peripheral nerve injuries: What is the place for ultrasound?
2016
OBJECTIVE The purpose of this study was to evaluate the usefulness of ultrasound in the preoperative workup of peripheral nerve lesions and illustrate how nerve ultrasonography can be integrated in routine clinical and neurophysiological evaluation and in the management of focal peripheral nerve injuries. The diagnostic role and therapeutic implications of ultrasonography for different neuropathies are described. METHODS The authors analyzed the use of ultrasound in 119 entrapment, tumoral, posttraumatic, or postsurgical nerve injuries of limbs evaluated in 108 patients during 2013 and 2014. All patients were candidates for surgery, and in all cases the evaluation included clinical examina…
The little finger ulnar palmar digital artery perforator flap: anatomical basis.
2013
PURPOSE: The aim of this study was to explore the cutaneous vascularization of the hypothenar region and investigate the anatomical basis for perforator propeller flaps for coverage of the flexor aspect of the little finger. METHODS: The area between the pisiform and the base of the little finger was studied in 14 hands of fresh cadavers injected with red latex. An oval flap 1.5 cm large was raised along the axis between these two points. Perforators going into the flap were dissected up to their origin from the ulnar palmar digital artery of the little finger, and their distance from the proximal edge of the A1 pulley was recorded. RESULTS: The mean number of perforator arteries entering t…
Response to "The ulnar palmar perforator flap: Anatomical study and clinical application"
2014
A rare case of peri-implant distal radius fracture☆
2021
A peri-implant fracture near the volar plate of distal radius represent a very rare injury. The main factor of this lesion is high energy trauma on the wrist. We report a case of a 61-year-old woman with a peri-implant fracture located just proximally to the plate and a fracture of the ulnar head that occurred after a simple fall. The patient was surgically treated by plate and screws removal. The fracture was fixed using a longer volar plate for the radial fracture and a plate for the head ulnar fracture. Different factors such as osteoporosis, BMI and screw position could influence the fracture pattern. However, considering growing use of plates for distal radius fracture fixation, the fr…
Pressure Monitoring of Intraneural an Perineural Injections Into the Median, Radial, and Ulnar Nerves; Lessons From a Cadaveric Study
2015
Background: Nerve damage after regional anesthesia has been of great concern to anesthetists. Various modalities have been suggested to recognize and prevent its incidence. An understudied area is the measurement of intraneural pressure during peripheral nerve blockade. Previous investigations have produced contradicting results with only one study being conducted on human cadavers. Objectives: The purpose of this investigation was to systematically record intraneural and perineural injection pressures on the median, ulnar, and radial nerves exclusively as a primary outcome. Materials and Methods: Ultrasonography-guided injections of 1 mL of 0.9% NaCl over ten seconds were performed on phen…
Volar and dorsal mid-shaft forearm plating using DCP and LC-DCP: interference with the interosseous membrane and forearm-kinematics.
2010
Purpose To clarify if dorsal plate osteosynthesis of the forearm shaft is associated with impingement of the interosseous membrane (IOM) and if rotational kinematics of the forearm are influenced. Background Forearm fractures are treated by separate incisions. Osteosynthesis via one approach in proximal forearm fractures was associated with higher rates of synostosis. It has been claimed that this is due to IOM impingement. Materials and methods 16 forearms of fresh frozen cadavers were dissected until only radius, ulna and the IOM remained. To preserve physiological forearm rotation, the elbow joint, the distal radio-ulnar joint and the carpus remained intact. In group 1, LC-DC and DC plat…
Lussazione abituale del nervo ulnare al gomito: proposta di nuova tecnica chirurgica
2012
How was the Turin Shroud Man crucified?
2014
As the literature is not exhaustive with reference to the way the Turin Shroud (TS) Man was crucified, and it is not easy to draw significant information from only a "photograph" of a man on a linen sheet, this study tries to add some detail on this issue based on both image processing of high resolution photos of the TS and on experimental tests on arms and legs of human cadavers. With regard to the TS Man hands, a first hypothesis states that the left hand of the TS Man was nailed twice at two different anatomical sites: the midcarpal joint medially to the pisiform between the lunate/pyramidal and capitate/uncinate bones (Destot's space) and the radiocarpal joint between the radio, lunate…
Elevage et consommation en territoire arverne. : De l'agglomération d'Aulnat aux oppida du bassin clermontois, changements ou continuité ?
2010
Textes en français et en allemand. - Actes du 34ème colloque de l'AFEAF organisé du 13 au 16 mai 2010 à Aschaffenburg Allemagne). - Textes et avant-propos en allemand et en français. Bibliogr. en fin de contributions; International audience