Search results for "Ultra"

showing 10 items of 4451 documents

Effect of three different irrigation solutions applied by passive ultrasonic irrigation

2015

Objectives This study evaluated the maximum depth and percentage of irrigant penetration into dentinal tubules by passive ultrasonic irrigation (PUI). Materials and Methods Thirty extracted human teeth were instrumented and divided into three groups. According to final irrigation regimen, 5.25% sodium hypochlorite (Group A, NaOCl), 2% chlorhexidine (Group B, CHX) and saline solution (Group C, control group) were applied with Irrisafe 20 tips (Acteon) and PUI. Irrigant was mixed with 0.1% rhodamine B. Sections at 2 mm, 5 mm, and 8 mm from the apex were examined with confocal laser scanning microscopy (CLSM). The percentage and maximum depth of irrigant penetration were measured. Kruskal-Wall…

Ultrasonic irrigationMaterials scienceDentinal penetrationConfocal laser scanning microscopeConfocal laser scanning microscopeChlorhexidineNanotechnologyGeneral MedicinePenetration (firestop)lcsh:RK1-715Passive ultrasonic irrigationSodium hypochloritestomatognathic diseaseschemistry.chemical_compoundDentinal Tubulestomatognathic systemchemistryMaximum depthlcsh:DentistrySodium hypochloriteIrrigation SolutionsResearch ArticleBiomedical engineeringRestorative Dentistry & Endodontics
researchProduct

Effectiveness of passive ultrasonic irrigation in improving elimination of smear layer and opening dentinal tubules

2014

Objective: To compare the ability to eliminate debris and open dentinal tubules of different ultrasound irrigation procedures. Study Design: Forty extracted single-rooted human teeth were instrumented with mechanical rotatory instrumentation, and divided into four groups: (n=10) according to the final irrigation technique: group A (control), 2.5% NaOCl irrigation with the Miraject needle and no ultrasonic agitation; group B, passive ultrasonic irrigation (PUI) with 2.5% NaOCl and Irrisafe 20 tips; group C, PUI with 2.5% NaOCl and Irrisafe 25 tips; group D, PUI with 2.5% NaOCl and K 25 tips. The amount of debris and the number of opened dentinal tubules was established by scanning electronic…

Ultrasonic irrigationbusiness.industryResearchIrrigation techniqueUltrasoundSmear layerDentistryOdontología:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludDentinal TubuleClinical and Experimental DentistryUNESCO::CIENCIAS MÉDICASMedicinebusinessGeneral Dentistry
researchProduct

Some tests of 3D ultrasonic traveltime tomography on the Eleonora d'Aragona statue (F. Laurana, 1468)

2013

Abstract The use of a non-destructive technique in situ can be a valuable diagnostic tool to support verification of restoration, as well as a monitoring technique in works of art or historical monuments. We present a high resolution 3D ultrasonic tomography to one of the most important statues of the Regional Gallery of Palazzo Abatellis of Palermo, the bust of Eleonora d'Aragona by F. Laurana (1430–1502). This technique allowed to study the structural continuity of the material of the marble. Some tests have been carried out to optimize inversion parameters, such as voxel size and to choose between straight and curved rays. We propose to calculate a minimum lateral resolution using the sa…

Ultrasonic measurements 3D tomography Inversion tests Lateral resolution Voxel size Raytracingbusiness.industry3d tomographyLateral resolutionGeophysicsOpticsHomogeneousUltrasonic TomographyUltrasonic sensorStatueTomographybusinessVoxel sizeGeology
researchProduct

Continuous monitoring of an intentionally-manufactured crack using an automated welding and in-process inspection system

2020

Abstract Automated weld deposition coupled with the real-time robotic Non-Destructive Evaluation (NDE) is used in this paper. For performance verification of the in-process inspection system, an intentionally embedded defect, a tungsten rod, is introduced into the multi-pass weld. A partially-filled groove (staircase) sample is also manufactured and ultrasonically tested to calibrate the real-time inspection implemented on all seven layers of the weld which are deposited progressively. The tungsten rod is successfully detected in the real-time NDE of the deposited position. The same robotic inspection system was then used to continuously monitor an intentionally-manufactured crack for 20 h.…

Ultrasonic phased arrayMaterials scienceTKMechanical engineeringchemistry.chemical_element02 engineering and technologyWeldingTungsten010402 general chemistryRobotic NDE01 natural sciencesSignallaw.inventionRobot weldingSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di Macchinelawlcsh:TA401-492Deposition (phase transition)In-process inspectionRobotic weldingGeneral Materials ScienceIntentionally manufactured weld defectsGroove (music)Mechanical EngineeringContinuous monitoringCrack growth monitoringWork in process021001 nanoscience & nanotechnology0104 chemical scienceschemistryMechanics of Materialslcsh:Materials of engineering and construction. Mechanics of materials0210 nano-technology
researchProduct

Ultrasonic phased array inspection of wire plus arc additive manufacture ‎‎(WAAM) samples using conventional and total focusing method (TFM) ‎imaging…

2018

In this study, three aluminium samples produced by wire + arc additive manufacture (WAAM) are inspected using ultrasonic phased array technology. Artificial defects are machined using a centre drill, ø3 mm, and electro-discharge machining (EDM), ø0.5-1 mm, in a cylindrical through hole topology. The sample was first inspected by a single element wheel probe mounted on a KUKA robot in order to investigate the feasibility of using a conventional ultrasonic transducer approach. Unfortunately, the wheel probe was found to be unsuitable for scanning of the WAAM specimens and ultrasonic phased arrays were employed next. The setup included 5 MHz and 10 MHz arrays (128 elements) in direct contact w…

Ultrasonic phased arraySettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineWire + Arc additive manufacture (WAAM)Full matrix capture (FMC)Total focusing method (TFM)Artificial defects
researchProduct

Influence of seamless pipes wall thickness variation for the effectiveness of Automated Ultrasonic Testing

2015

Offshore pipelines construction is a technological challenge. Increasing water depth, harsh environments, engineering and commercial constraints are just some of the existing issues. Material selection therefore plays a key role and, for several applications, seamless pipes offer both the best technical and commercial compromise. Typically, NDT inspection of girth welds is carried out using the phased array based automated ultrasonic testing (AUT) zonal discrimination approach. AUT, compared to other techniques, guarantees a higher probability of detection of flaws and it also allows a really accurate assessment of the indications. However, since one of the peculiarities of this technique i…

Ultrasonic Phased Array Pipelines NDT modelling AUT
researchProduct

Adhesive debonding detection of FRP reinforcement by the ultrasonic non-destructive technique

2015

Fiber reinforced polymer (FRP) composite systems are extensively used for repairing and reinforc- ing structurally inefficient concrete structures. The performance of an FRP rehabilitation system is highly influenced by its integrity. In particular, the presence of defects, e.g. voids, inclusions, debonds, improper cure and delaminations, caused by an inaccurately manufacture and installation, may affect the capability of the rehabilitated structure. For this reason, non-destructive (ND) meth- ods could be used to assess the quality of the reinforcement [1,2]. In this work an ultrasonic ND technique for detecting delamination defects in FRP reinforcement is presented. The technique couples …

UltrasonicNon-destructive testingSettore ICAR/08 - Scienza Delle CostruzioniFRP
researchProduct

ESPLORAZIONE ULTRASONOGRAFICA dello SCROTO. Ruolo Diagnostico ed Implicazioni Terapeutiche in Età Pediatrica

1989

Ultrasonography of the scrotal contents was used to identify 41 patients with testicular disease.

Ultrasonography scrotal diseaseSettore MED/20 - Chirurgia Pediatrica E InfantileSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct

Geophysical surveys for the restoration of Branciforte Palace in Palermo

2019

A multi-methodological and non-invasive geophysical study has been carried out in order to support the restoration project of the historic Branciforte Palace in Palermo. Ground Penetrating Radar profiles and an Electrical Resistivity Tomography ERT, carried out on the floor of the stable of the Palace, allowed to evaluate in detail the state of consolidation of the subsoil, in correspondence of a double row of marble columns, some of which were affected by differential subsidence. These columns have been investigated by means of Ultrasonic Tomography to verify their state of degradation. Moreover Infrared Thermography images of the internal and external walls and of the vaults highlighted d…

Ultrasound TomographygeoradarSettore GEO/11 - Geofisica ApplicataNon-invasiveInfrared ThermographyElectrical resistivity tomography
researchProduct

Trans-Abdominal Ultrasound Guided ERC in a Pregnant Woman With Bile Duct Stones

2014

Background: The change in lithogenicity of bile, increased stasis of bile and decreased gall bladder emptying are the possible reasons for an increased risk of gall stones during pregnancy. However, biliary interventions during pregnancy are associated with risks to both the pregnancy and developing fetus. ERC under fluoroscopic control as gold standard is associated with higher risk of premature labor and teratogenity. Methods and patient: We performed transabdominal ultra-sound guided ERC in one patient in the second trimenon with gall stones. While the hilus area is observed by ultrasound, the papilla is carefully cannulated with a guidewire. A contrast agent is applied in the common bil…

Ultrasound guided ERCPmedicine.medical_specialtylcsh:Medical technologydigestive systemPregnancymedicineFluoroscopyRadiology Nuclear Medicine and imagingFetusPregnancyCommon bile ductmedicine.diagnostic_testBile ductbusiness.industryUltrasoundGastroenterologyVideomedicine.diseaseSurgeryMajor duodenal papillamedicine.anatomical_structurelcsh:R855-855.5ComplicationbusinessBile duct stonesComplicationVideo Journal and Encyclopedia of GI Endoscopy
researchProduct