Search results for "Ultra"
showing 10 items of 4451 documents
CERN IRRADIATION FACILITIES.
2017
CERN provides unique irradiation facilities for applications in dosimetry, metrology, intercomparison of radiation protection devices, benchmark of Monte Carlo codes and radiation damage studies to electronics.
Generalizability and Simplicity as Criteria in Feature Selection: Application to Mood Classification in Music
2011
Classification of musical audio signals according to expressed mood or emotion has evident applications to content-based music retrieval in large databases. Wrapper selection is a dimension reduction method that has been proposed for improving classification performance. However, the technique is prone to lead to overfitting of the training data, which decreases the generalizability of the obtained results. We claim that previous attempts to apply wrapper selection in the field of music information retrieval (MIR) have led to disputable conclusions about the used methods due to inadequate analysis frameworks, indicative of overfitting, and biased results. This paper presents a framework bas…
Acoustic detection and classification of river boats
2011
We present a robust algorithm to detect the arrival of a boat of a certain type when other background noises are present. It is done via the analysis of its acoustic signature against an existing database of recorded and processed acoustic signals. We characterize the signals by the distribution of their energies among blocks of wavelet packet coefficients. To derive the acoustic signature of the boat of interest, we use the Best Discriminant Basis method. The decision is made by combining the answers from the Linear Discriminant Analysis (LDA) classifier and from the Classification and Regression Trees (CART) that is also accompanied with an additional unit, called Aisles, that reduces fal…
LOCAL CONTROL OF SOUND IN STOCHASTIC DOMAINS BASED ON FINITE ELEMENT MODELS
2011
A numerical method for optimizing the local control of sound in a stochastic domain is developed. A three-dimensional enclosed acoustic space, for example, a cabin with acoustic actuators in given locations is modeled using the finite element method in the frequency domain. The optimal local noise control signals minimizing the least square of the pressure field in the silent region are given by the solution of a quadratic optimization problem. The developed method computes a robust local noise control in the presence of randomly varying parameters such as variations in the acoustic space. Numerical examples consider the noise experienced by a vehicle driver with a varying posture. In a mod…
Ultrafast electronic relaxation and vibrational cooling dynamics of Au 144(SC2H4Ph)60 nanocluster probed by transient mid-IR spectroscopy
2014
Energy relaxation dynamics of a gold nanocluster with atomically precise composition, Au144(SC2H4Ph)60, is studied by transient mid-IR spectroscopy. The experiment is designed to simultaneously pro...
Molecule-like photodynamics of Au102(pMBA)44 nanocluster.
2015
Photophysical properties of a water-soluble cluster Au102(pMBA)44 (pMBA = para-mercaptobenzoic acid) are studied by ultrafast time-resolved mid-IR spectroscopy and density functional theory calculations in order to distinguish between molecular and metallic behavior. In the mid-IR transient absorption studies, visible or near-infrared light is used to electronically excite the sample, and the subsequent relaxation is monitored by studying the transient absorption of a vibrational mode in the ligands. Based on these studies, a complete picture of energy relaxation dynamics is obtained: (1) 0.5-1.5 ps electronic relaxation, (2) 6.8 ps vibrational cooling, (3) intersystem crossing from the low…
One-pot synthesis and characterization of subnanometre-size benzotriazolate protected copper clusters
2012
A simple one-pot method for the preparation of subnanometre-size benzotriazolate (BTA) protected copper clusters, Cu(n)BTA(m), is reported. The clusters were analyzed by optical and infrared spectroscopy, mass spectrometry and transmission electron microscopy together with computational methods. We suggest a structural motif where the copper core of the Cu(n)BTA(m) clusters is protected by BTA-Cu(i)-BTA units.
Ultraviolet B radiation induced alterations in immune function of fish : in relation to habitat preference and disease resistance
2009
Runsas altistuminen auringolle on tunnetusti haitallista ihmisten ja eläinten hyvinvoinnille. Eveliina Markkula tutki väitöskirjatyössään, miten ultravioletti B (UVB) -säteilylle altistuminen vaikuttaa kalojen vastustuskykyyn ja tautialttiuteen.- Ilmakehän otsonikerroksen oheneminen viime vuosikymmenten aikana on johtanut UVB-säteilyn lisääntymiseen maan pinnalla. UVB-säteily tunkeutuu myös kirkkaisiin järvi- ja merivesiin ja voi näin aiheuttaa haittaa kaloille, Markkula kertoo.UVB-säteilyn on jo aiemmin todettu lisäävän kalojen varhaisten elinvaiheiden epämuodostumia ja kuolleisuutta. Kertaluonteinenkin altistuminen lampuilla tuotetulle UVB-säteilylle aiheuttaa muutoksia kalan immuunijärje…
Doppler ultrasound and giant cell arteritis
2010
Ana Marina Suelves1, Enrique España-Gregori1,2, Jose Tembl3, Stephanie Rohrweck1, Jose Maria Millán4, Manuel Díaz-Llopis1,4,51Service of Ophthalmology, La Fe University Hospital, Valencia, Spain; 2Department of Optics, University of Valencia, Valencia, Spain; 3Service of Neurology, La Fe University Hospital, Valencia, Spain; 4CIBERER, Ciber de Enfermedades Raras, Valencia, Spain; 5Faculty of Medicine, University of Valencia, Valencia, SpainObjective: To evaluate the utility of ultrasound in aiding the diagnosis of giant cell arteritis (GCA), in monitoring the response to corticotherapy, and in detecting early relapses.Methods: A pilot study, prospective, inc…
High-Frequency and Ultra-High Frequency Ultrasound: Musculoskeletal Imaging up to 70 MHz
2020
AbstractMusculoskeletal (MSK) ultrasound has well-established advantages, able to investigate very small structures with high resolution and a quick and real-time dynamic evaluation with the possibility of contralateral comparison. Thus ultrasound has kept its own almost exclusive fields of application in daily clinical practice, and it is considered the first-level imaging technique to assess tendons, bursae, and capsuloligamentous structures of small peripheral joints as well as peripheral nerves. Up to now, however, clinical MSK ultrasound imaging could not go beyond the first 1 to 2 cm under the skin, using high-frequency probes up to 18 to 20 MHz with spatial resolution just below mill…