Search results for "Urine"

showing 10 items of 924 documents

Sensitive and selective plasmonic assay for spermine as biomarker in human urine.

2014

A simple, fast, and highly selective and sensitive colorimetric assay to detect nanomolar levels of spermine in human urine (healthy donors, cancer patients) is reported. This assay is based on the absence of a competitive organic capping on the gold nanoparticles together with the high affinity of the amine groups of the analyte for the nanoparticle surface.

AnalyteChromatographyChemistrySpermineMetal NanoparticlesUrineUrinalysisHighly selective3. Good healthAnalytical Chemistrychemistry.chemical_compoundBiomarkerBiochemistryColloidal goldLimit of DetectionHumansAmine gas treatingColorimetrySpermineGoldBiomarkersAnalytical chemistry
researchProduct

A new 8-oxo-7,8-2 ' deoxyguanosine nanoporous anodic alumina aptasensor for colorectal cancer diagnosis in blood and urine

2021

Many important human diseases, and especially cancer, have been related to the overproduction of 8-oxo-7,8-dihydro-2 '-deoxyguanosine (8-oxo-dG). This molecule is a product of oxidative stress processes over nucleophilic bases in DNA. In this work, an aptasensor for the rapid, selective and accurate detection of this oncomarker is presented. The aptasensor consists of a nanoporous anodic alumina material loaded with a dye and is functionalized with an aptamer-based "molecular gate". In the presence of target 8-oxo-dG, the capping aptamer displaces from the surface due to the high affinity of the analyte with the capping aptamer, thus inducing delivery of the preloaded fluorescent dye. In co…

AnalyteChromatographyNanoporousColorectal cancerChemistryAptamerDeoxyguanosineCancerUrinemedicine.diseaseFluorescenceNanoporeschemistry.chemical_compound8-Hydroxy-2'-DeoxyguanosineAluminum OxidemedicineHumansDeoxyguanosineGeneral Materials ScienceColorectal Neoplasms
researchProduct

Control of propranolol intake by direct chromatographic detection of alpha-naphthoxylactic acid in urine.

2002

A rapid chromatographic procedure with a C18 column, a mobile phase of 0.15 M sodium dodecyl sulfate (SDS)-10% (v/v) 1-propanol at pH 3 (0.01 M phosphate buffer), and fluorimetric detection, is reported for the control of propranolol (PPL) intake in urine samples, which are injected directly without any other treatment than filtration. The peak of PPL was only observed in samples taken a few hours after ingestion of the drug due to its extensive conjugation and metabolisation. The detection of several unconjugated PPL metabolites was therefore considered: desisopropylpropranolol (DIP), propranolol glycol (PPG), alpha-naphthoxylactic acid (NLT) and alpha-naphthoxyacetic acid (NAC). NLT showe…

AnalyteClinical BiochemistryAdrenergic beta-AntagonistsUrinePropranololBiochemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundOral administrationmedicineHumansSodium dodecyl sulfateDetection limitChromatographyElutionReproducibility of ResultsCell BiologyGeneral MedicinePropranololSpectrometry FluorescencechemistryMicellar liquid chromatographyLactatesmedicine.drugChromatography LiquidJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Micellar liquid chromatography determination of rivaroxaban in plasma and urine. Validation and theoretical aspects.

2019

A Micellar Chromatographic method to determine rivaroxaban in plasma and urine has been developed. The samples were dissolved in the mobile phase (SDS 0.05 M – 1-propanol 12.5%, phosphate buffered at pH 7) and 20 μL directly injected, avoiding the extraction and purification steps. Using a C18 column and running under isocratic mode at 1 mL/min, analyte was eluted without interference from the matrix in <6.0 min. The detection absorbance wavelength was set to 250 nm. The procedure was validated by Food and Drug Administration guidelines in terms of: system suitability, calibration range (0.05–5 mg/L), linearity, sensitivity, robustness, carry-over effect, specificity, accuracy (−11.1 to 4.2…

AnalyteClinical Biochemistrypartition equilibriumUrine030226 pharmacology & pharmacy01 natural sciencesBiochemistryAnalytical Chemistrymicellar chromatographyMatrix (chemical analysis)03 medical and health scienceschemistry.chemical_compound0302 clinical medicineRivaroxabanLimit of Detectiondirect injectionHumansMicellesvalidationChromatographyElutionanticoagulant010401 analytical chemistryExtraction (chemistry)biological fluidReproducibility of ResultsCell BiologyGeneral MedicinePhosphate0104 chemical scienceschemistryMicellar liquid chromatographyPartition equilibriumLinear ModelsChromatography LiquidJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine by capillary electrophoresis using ultraviolet absorba…

2002

Abstract Two capillary electrophoresis methods have been developed for the direct determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine. Analytes were detected using conventional UV detection as well as laser-induced fluorescence (LIF) detection with an HeCd-laser operating at a wavelength of 325 nm. The results of both detection techniques were compared. Indeed, the limit of quantification was eightfold lower using LIF detection (50 ng/ml) in comparison to UV detection (400 ng/ml). As no interference due to endogenous urine compounds was observed, direct urine analysis was feasible. Analysis was very simple and fast—one run could be performed within…

AnalyteMetaboliteClinical BiochemistryUrineBiochemistryAnalytical Chemistrychemistry.chemical_compoundCapillary electrophoresismedicineHumansDiureticsLaser-induced fluorescenceDetection limitTriamtereneChromatographyChemistryLasersElectrophoresis CapillaryReproducibility of ResultsCell BiologyGeneral MedicineFluorescenceSpectrometry FluorescenceSpectrophotometry UltravioletTriamterenemedicine.drugJournal of Chromatography B
researchProduct

Speichel als Matrix für das Humanbiomonitoring in der Arbeits- und Umweltmedizin [Biomonitoring Methods in German Language, 2015]

2016

Saliva as a matrix for human biomonitoring in occupational and environmental medicine Purpose: Human biomonitoring (HBM) implies the assessment of internal exposure to hazardous substances by measuring the substances, their metabolites or reaction products, as well as effect parameters in human body fluids. Along with blood, plasma and urine, saliva is of increasing interest as an alternative matrix for HBM. Methods: This paper reviews studies that measure salivary background levels of hazardous substances, elevated levels after environmental or occupational exposure, as well as references which deal with physiological and toxicokinetic behaviour of saliva and salivary parameters, respectiv…

AnalyteSalivaChromatographybusiness.industry010401 analytical chemistry030206 dentistryUrine01 natural sciences0104 chemical sciences03 medical and health scienceschemistry.chemical_compound0302 clinical medicinechemistryBiomonitoringMedicineBiomarker (medicine)CotininebusinessEnvironmental medicineExposure data
researchProduct

Assessment of oxidative damage to proteins and DNA in urine of newborn infants by a validated UPLC-MS/MS approach

2014

The assessment of oxidative stress is highly relevant in clinical Perinatology as it is associated to adverse outcomes in newborn infants. This study summarizes results from the validation of an Ultra Performance Liquid Chromatography-tandem Mass Spectrometry (UPLC-MS/MS) method for the simultaneous quantification of the urinary concentrations of a set of endogenous biomarkers, capable to provide a valid snapshot of the oxidative stress status applicable in human clinical trials, especially in the field of Perinatology. The set of analytes included are phenylalanine (Phe), para-tyrosine (p-Tyr), ortho-tyrosine (o-Tyr), meta-tyrosine (m-Tyr), 3-NO2-tyrosine (3NO(2)-Tyr), 3-Cl-tyrosine (3Cl-T…

AnalyteScienceUrinary systemUrineResearch and Analysis Methodsmedicine.disease_causeTandem mass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryOxidative DamageTandem Mass SpectrometryDiagnostic MedicineLiquid chromatography–mass spectrometryNucleic AcidsDNA-binding proteinsMedicine and Health SciencesmedicineHumansClinical ChemistryMultidisciplinaryChromatographyBiology and life sciencesbusiness.industryQChromatographic TechniquesRInfant NewbornProteinsDNAClinical Laboratory SciencesClinical trialOxidative StressChemistryBioassays and Physiological AnalysisPhysical SciencesMedicineMedicinal ChemistryBiochemical AnalysisbusinessBiomarkersOxidative stressResearch Article
researchProduct

An investigation of the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid in authentic urine samples.

2004

Preanalytical stability of a drug and its major metabolites is an important consideration in pharmacokinetic studies or whenever the analyte pattern is used to estimate drug habits. Firstly, the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH, THCCOOglu) in authentic urine samples was investigated. Random urine samples of cannabis users (n = 38) were stored at -20, 4, and 20 degrees C up to 15 days and up to 5 days at 40 degrees C, and alterations of the analyte pattern during storage were followed by liquid chromatography-tandem mass spectrometry. Secondly, the influence of pH (range 5.0-8.0) on the stability of the analytes was studied us…

AnalyteSubstance-Related DisordersHealth Toxicology and MutagenesisCarboxylic acidMetaboliteUrineToxicologyHigh-performance liquid chromatographyMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundGlucuronidesPharmacokineticsDrug StabilityEnvironmental ChemistryHumansDronabinolDiagnostic Errorschemistry.chemical_classificationChemical Health and SafetyChromatographyForensic MedicineHydrogen-Ion ConcentrationSubstance Abuse DetectionchemistryΔ9-tetrahydrocannabinolGlucuronideArtifactsJournal of analytical toxicology
researchProduct

Wide-range screening of banned veterinary drugs in urine by ultra high liquid chromatography coupled to high-resolution mass spectrometry

2012

In this work, an ultra high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) methodology is proposed for the multi-class multi-residue screening of banned and unauthorized veterinary drugs in bovine urine, using an Orbitrap Exactive™ analyzer working at a resolving power of 50,000 FWHM in full scan, both in positive and negative mode. The method currently covers 87 analytes belonging to different families such as steroid hormones, β-agonists, resorcylic acid lactones (RAL), stilbens, tranquillizers, nitroimidazoles, corticosteroids, NSAIDs, amphenicoles, thyreostatics and other substances such as dapsone. A database including the elemental composition, the po…

AnalyteVeterinary DrugsUrineQuechersOrbitrapSensitivity and SpecificityBiochemistryMass SpectrometryAnalytical Chemistrylaw.inventionlawAnimalsEuropean UnionAnimal HusbandryChromatography High Pressure LiquidElemental compositionChromatographyChemistryOrganic ChemistryReproducibility of ResultsVeterinary DrugsGeneral MedicineDrug ResiduesCattleUltra high performanceRetention timeJournal of Chromatography A
researchProduct

Murine Typhus and Hemophagocytic Syndrome

2018

No Abstract

Anemia030231 tropical medicineMEDLINEMurine typhusLymphohistiocytosis HemophagocyticMice03 medical and health sciences0302 clinical medicineAnti-Bacterial AgentmedicineAnimalsHumansAnimalbusiness.industryAnemiaTyphus Endemic Flea-BorneHematologymedicine.diseaseThrombocytopeniaAnti-Bacterial AgentsOncologyPediatrics Perinatology and Child HealthImmunology030211 gastroenterology & hepatologybusinessTyphusHumanJournal of Pediatric Hematology/Oncology
researchProduct