Search results for "Urine"
showing 10 items of 924 documents
DNA damage photo-induced by chloroharmine isomers: hydrolysis versus oxidation of nucleobases
2018
Photodynamic therapy (PDT) is an emerging clinical treatment currently being used against a wide range of both cancerous and noncancerous diseases. The search for new active photosensitizers as well as the development of novel selective delivery systems are the major challenges faced in the application of PDT. We investigated herein three chloroharmine derivatives (6-, 8- and 6,8-dichloroharmines) with quite promising intrinsic photochemical tunable properties and their ability to photoinduce DNA damage in order to elucidate the underlying photochemical mechanisms. Data revealed that the three compounds are quite efficient photosensitizers. The overall extent of photo-oxidative DNA damage i…
Principal component analysis on molecular descriptors as an alternative point of view in the search of new Hsp90 inhibitors
2009
Inhibiting a protein that regulates multiple signal transduction pathways in cancer cells is an attractive goal for cancer therapy. Heat shock protein 90 (Hsp90) is one of the most promising molecular targets for such an approach. In fact, Hsp90 is a ubiquitous molecular chaperone protein that is involved in folding, activating and assembling of many key mediators of signal transduction, cellular growth, differentiation, stress-response and apoptothic pathways. With the aim to analyze which molecular descriptors have the higher importance in the binding interactions of these classes, we first performed molecular docking experiments on the 187 Hsp90 inhibitors included in the BindingDB, a pu…
Determination of methamphetamine in urine samples with sodium 1,2-naphthoquinone-4-sulphonate
1994
Optimal conditions have been studied for the determination of methamphetamine in urine samples by an extractive-spectrophotometric method with sodium 1,2-naphthoquinone-4-sulphonate (NQS) as reagent. These conditions are: NaHCO3 pH 10, NQS 6.3 × 10−3 mol/l and heating for 5 min at 45°C. The accuracy and precision of the method were tested. The detection limits were 0.2 mg/l in the standard and 0.9 mg/l when 5 ml of urine sample were taken. The standard deviation of blank urine was evaluated from 12 different samples. The relative errors found in the determination of methamphetamine in urine were lower than 10% if the methamphetamine-amphetamine ratio was higher than 4.
Influence of the differentiation system on the analytical parameters for the spectrophotometric determination of clonazepam in urine
1991
Abstract Electronic and mathematical differentiation of the ultraviolet visible spectra were compared from the study of the analytical parameters of the direct determination of clonazepam in urine samples. Third-order derivative spectra were used. The mathematical differentiation provides higher sensitivity, a lower limit of detection, and better accuracy and precision than the electronic one. The use of a diode array instrument provides lower sensitivity than that found using a conventional spectrometer; however, the limit of detection obtained in both cases is of the same order.
Analysis of LSD in human body fluids and hair samples applying ImmunElute columns.
2000
Immunoaffinity extraction units (LSD ImmunElute) are commercially available for the analysis of lysergic acid diethylamide (LSD) in urine. The ImmunElute resin contains immobilized monoclonal antibodies to LSD. We applied the ImmunElute procedure to serum and also to human hair samples. For hair analysis the samples were first extracted with methanol under sonication. The extracts were then purified using the ImmunElute resin. LSD analysis was carried out with HPLC and fluorescence detection. The immunoaffinity extraction provides highly purified extracts for chromatographic analysis. The limit of detection (signal-to-noise ratio = 3) has been determined to be < 50 pg regardless of which sa…
Sequential-injection determination of traces of disodium phenyl dibenzimidazole tetrasulphonate in urine from users of sunscreens by on-line solid-ph…
2005
Abstract A sensitive and selective method to determine disodium phenyl dibenzimidazole tetrasulphonate (PDT) in the urine of sunscreen users, which is suitable for studies on body accumulation/excretion is proposed. On-line solid-phase extraction allows the analyte to be retained and subsequentely eluted, using a strong anion exchange (SAX) microcolumn. Standard addition calibration was carried out with only one standard. The wavelengths of excitation and emission were 330 and 454 nm, respectively. The method allows PDT to be determined in both, spiked and unspiked human urine samples, without any pre-treatment. Results obtained for spiked urine samples (40–200 ng ml −1 ) showed the accurac…
High-performance liquid chromatographic determination of spironolactone and its major metabolite canrenone in urine using ultraviolet detection and c…
1994
A rapid and simple column liquid chromatographic method involving a column-switching system for the determination of spironolactone and its main metabolite canrenone in urine is described. Purification and concentration was performed using an Hypersil ODS-C18, 30 microns (20 x 2.1 mm I.D.) pre-column. The most polar urinary compounds were removed by washing the pre-column with water, and the analytes were subsequently switched to a LiChrospher RP C18, 5 microns (125 x 4 mm I.D.) analytical column and separated by means of an acetonitrile-water mobile-phase. Under the proposed conditions, the extraction efficiency was approximately 100% over the 0.5-10.0 micrograms/ml concentration range. Th…
Sensitive determination of ethacrynic acid in urine samples by reversed-phase liquid chromatography with ultraviolet detection using solid-phase extr…
1992
Abstract A rapid method is described for the identification and determination of ethacrynic acid in human urine samples by liquid chromatography with UV detection, the retention time of the analyte being 4.9 min. The samples were previously conditioned using C 18 solid-phase extraction columns and chromatographed on an HP-LiChrospher RP C 18 column (5 μm; 125 mm × 4 mm i.d.) with gradient elution with acetonitrile-acetate buffer (pH 4). The detector was set at 275 nm and furosemide was used as an internal standard. The procedure was applied to the determination of ethacrynic acid at concentrations of 0.01-10 μg ml -1 and the limit of detection was 6 ng ml -1 .
On-line trace enrichment for the determination of ethacrynic acid in urine by liquid chromatography and column-switching
1993
Abstract A chromatographic method based on liquid chromatography (LC) using column-switching for the determination of ethacrynic acid in urine samples, is described. The proposed system uses a Hypersil ODS-C18, 30 μm (20 mm × 2.1 mm i.d.) pre-column for the pre-concentration and separation of ethacrynic acid from the biological matrix. Polar urinary compounds are removed by flushing the pre-column with purified water, and the enriched analyte is then switched in back-flush mode onto an HP-LiChrospher RP C18, 5 μm (125 × 4 mm i.d.) analytical column, where it is chromatographed using an acetonitrile-acetate buffer gradient elution. The UV detector was set at 275 nm. The recovery of drug was …
Method and apparatus using selected superparamagnetic labels for rapid quantification of immunochromatographic tests
2009
Mika PA Laitinen1, Jari Salmela2, Leona Gilbert1, Risto Kaivola1, Topi Tikkala2, Christian Oker-Blom1, Jukka Pekola3, Matti Vuento11Department of Biological and Environmental Science; 2Department of Physics, University of Jyv&auml;skyl&auml;, Jyv&auml;skyl&auml;, Finland; 3Low Temperature Laboratory, Helsinki University of Technology, Helsinki, FinlandAbstract: A rapid method and instrumentation for quantification of immunochromatographic tests (ICT) are described. The principle and performance of the method was demonstrated by measuring the levels of human chorionic gonadotropin (hCG) present in urine. The test format was a sandwich assay using two distinct monoclonal antib…