Search results for "VISION"

showing 10 items of 5066 documents

Classification of SD-OCT Volumes Using Local Binary Patterns: Experimental Validation for DME Detection

2016

International audience; This paper addresses the problem of automatic classification of Spectral Domain OCT (SD-OCT) data for automatic identification of patients with Diabetic Macular Edema (DME) versus normal subjects. Optical Coherence Tomography (OCT) has been a valuable diagnostic tool for DME, which is among the most common causes of irreversible vision loss in individuals with diabetes. Here, a classification framework with five distinctive steps is proposed and we present an extensive study of each step. Our method considers combination of various pre-processings in conjunction with Local Binary Patterns (LBP) features and different mapping strategies. Using linear and non-linear cl…

genetic structures[INFO.INFO-IM] Computer Science [cs]/Medical Imaging[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processing[ INFO.INFO-CV ] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]0302 clinical medicine[INFO.INFO-CV] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Segmentationlcsh:OphthalmologySpeckleLBPDiagnosisPrevalencePreprocessorComputer visionSegmentationmedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingExperimental validationDiabetic Macular Edema[ SDV.MHEP.OS ] Life Sciences [q-bio]/Human health and pathology/Sensory OrgansOptical Coherence Tomography[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingResearch ArticleArticle SubjectLocal binary patterns03 medical and health sciencesSpeckle patternOptical coherence tomography[ SDV.MHEP ] Life Sciences [q-bio]/Human health and pathologyMedical imagingmedicineDME[INFO.INFO-IM]Computer Science [cs]/Medical ImagingCoherence (signal processing)Texture[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrgansRetinopathy[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processingbusiness.industry[INFO.INFO-CV]Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Pattern recognitioneye diseasesOphthalmologyOCTlcsh:RE1-994030221 ophthalmology & optometryImagesArtificial intelligencebusiness030217 neurology & neurosurgery[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
researchProduct

Induced Night-Vision by Singlet-Oxygen-Mediated Activation of Rhodopsin

2019

In humans, vision is limited to a small fraction of the whole electromagnetic spectrum. One possible strategy for enhancing vision in deep-red or poor-light conditions consists of recruiting chlorophyll derivatives in the rod photoreceptor cells of the eye, as suggested in the case of some deep-sea fish. Here, we employ all-atom molecular simulations and high-level quantum chemistry calculations to rationalize how chlorin e6 (Ce6), widely used in photodynamic therapy although accompanied by enhanced visual sensitivity, mediates vision in the dark, shining light on a fascinating but largely unknown molecular mechanism. First, we identify persistent interaction sites between Ce6 and the extra…

genetic structuresbiology010405 organic chemistrySinglet oxygenPhotoreceptor proteinRetinal010402 general chemistry01 natural sciencesVisual sensitivityeye diseasesTransmembrane protein0104 chemical scienceschemistry.chemical_compoundchemistryRhodopsinNight visionbiology.proteinBiophysics[CHIM]Chemical SciencesGeneral Materials SciencePhysical and Theoretical ChemistryComputingMilieux_MISCELLANEOUSVisual phototransduction
researchProduct

Phase retrieval for studying the structure of vitreous floaters simulated in a model eye

2021

We simulate vitreous floaters in a model eye and apply a phase retrieval algorithm to recover the structure of the vitreous floaters. The algorithm requires modulating the object under study by a r...

genetic structuresbusiness.industryComputer scienceFourier opticsStructure (category theory)Object (computer science)eye diseasesAtomic and Molecular Physics and OpticsVitreous FloaterComputer visionsense organsArtificial intelligencePhase retrievalbusinessJournal of Modern Optics
researchProduct

<title>Additional usage possibilities for the computerized Hess screen</title>

2003

The purpose of the study was to work out a method how to use the computerized Hess screen in proximal vergence measurements. Proximal vergence or vergence due to knowledge of nearness is one of four independent components making up the total vergence response. Proximal vergence is expressed as a ratio - proximal convergence/test distance (PC/T). The computerized Hess screen is usually used to detect and to measure an ocular misalignment in patients with paralytic strabismus in different directions of gaze. The computerized Hess screen can be used to assess PC/T ratio in different directions of gaze, providing the open-loop disparity vergence and accommodation systems and assuming that tonic…

genetic structuresbusiness.industryComputer scienceHess-screenVergenceGazeStandard deviationComputer visionIn patientPinhole (optics)Artificial intelligencebusinessAccommodationTest distanceSPIE Proceedings
researchProduct

Detection of rupture lines for active scanning

2007

Corner and junction detection is an important preprocessing step in image registration, data fusion, object recognition, and many other tasks. This work deals with corner and junction detection of characteristic features of the structure resulting from cross-pattern projection. The ultimate aim is to adapt the positions and orientation of the cross-pattern projections to what has been observed. The use of this projected light pattern in the framework of active vision allows us to identify certain points of interest on 3-D objects, to directly acquire a synthesis, which thus permits simplified detection, measurement, recognition, or tracking. We present detection methods for corners and junc…

genetic structuresbusiness.industryComputer scienceOrientation (computer vision)General EngineeringCorner detectionImage registrationAtomic and Molecular Physics and OpticsHough transformlaw.inventionInterest point detectionObject-class detectionWaveletlawComputer visionArtificial intelligenceActive visionProjection (set theory)businessOptical Engineering
researchProduct

Contrast sensitivity perimetry tests along the cardinal directions in color space: Correlation with the properties of the neural mechanisms mediating…

2014

It is well-known the advantages of measuring chromatic and achromatic contrast sensitivity for detecting pathologies. But these measurements are rarely used in clinical practice, due the complexity of the measurements and the examinator specialization. In fact, there is not a complete characterization of the response of the visual pathways to achromatic and chromatic spatio-temporal frequency stimuli. We have designed a new experimental device that facilitates these measurements and allow us to characterize the visual response in healthy patients. In this paper, we evaluated the responses of the visual pathways in healthy patients.

genetic structuresbusiness.industryMechanical Engineeringmedia_common.quotation_subjectColor spaceVisual systemAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionCorrelationAchromatic lenslawContrast (vision)Computer visionSensitivity (control systems)Artificial intelligenceChromatic scalebusinessEngineering (miscellaneous)media_commonCardinal directionMathematicsOptica Pura y Aplicada
researchProduct

Multispectral analysis and cone signal modelling of pseudoisochromatic test plates

2013

The aim of the study is to determine the consistency of the desired colour reproduction of the stimuli using calibrated printing technology available to anyone (EpsonStylus Pro 7800 printer was). 24 colour vision assessment plates created in the University of Latvia were analysed right after their fabrication on august 2012 and after intense use for 7 months (colour vision screening on 700 people). Multispectral imagery results indicate that the alignment of the samples after seven months of use has maintained on the CIExy confusion lines of deutan deficiency type, but the shift towards achromatic area in the diagram indicate decrease in the total colour difference (ΔE*ab) of test backgroun…

genetic structuresbusiness.industryMultispectral imageSignallaw.inventionColour differenceGeographyAchromatic lenslawConsistency (statistics)medicineComputer visionChromatic scaleArtificial intelligenceSeverity levelmedicine.symptombusinessConfusionIOP Conference Series: Materials Science and Engineering
researchProduct

2015

The combination of local orientation collinearity and spatial frequency contrast in contour integration was studied in two experiments using a 2AFC contour detection and discrimination task. Target contours were defined by local orientation collinearity, spatial frequency contrast between contour and background elements, or both cues. Experiments differed in the source of spatial frequency contrast by manipulating the spatial frequency of either contour or background elements. Cue summation gains, defined as the performance benefit of double cue conditions over single cue conditions, were evaluated and tested against the predictions derived from probability summation and linear summation. S…

genetic structuresbusiness.industryOrientation (computer vision)media_common.quotation_subjectContext (language use)Pattern recognitionCollinearityMethods of contour integrationSensory SystemsOphthalmologyOpticsFeature (computer vision)Contrast (vision)Spatial frequencyArtificial intelligencebusinessAnisotropyMathematicsmedia_commonJournal of Vision
researchProduct

<title>Modified crossed-cylinder aberroscope</title>

2001

We report a technique to estimate eye aberrations, based mainly on the subjective crossed-cylinder method. In order to obtain accurate coordinates of cross sections of the aberration distorted grid image on the retinal plane, needed in subjective methods, fusion of two images is used. The image seen by the eye under investigation is fused by the patient with a similar grid generated and reshaped in the appropriate way on the computer screen. The computer simulated image is viewed either by the second eye (in order to avoid eye rivalry and suppression processes, that are typical for such conditions, stimuli for both eyes are discontinuous and are displayed sequentially with a frequency of 50…

genetic structuresbusiness.industryPlane (geometry)Computer scienceDistortion (optics)eye diseasesComputing systemsmedicine.anatomical_structureOpticsmedicineCylinderHuman eyeComputer visionsense organsArtificial intelligencebusinessSPIE Proceedings
researchProduct

Automatic Conjunctival Provocation Test Using Hough Transform of Extended Canny Edge Maps

2013

Computer-aided diagnosis is developed for assessment of allergic rhinitis/rhinoconjunctivitis measuring the relative redness of sclera under application of allergen solution. The patient’s eye images are taken from commercial digital camera. The iris is robustly localized using a gradient-based Hough circle transform. From the center of the pupil, the region of interest within the sclera is extracted using geometric anatomybased a-priori information. The red color pixels are extracted thresholding in the hue, saturation and value color space. Then, redness is measured by taking mean of saturation projected into zero hue. Evaluation is performed with 92 images taken from 13 subjects, 8 respo…

genetic structuresbusiness.industryProvocation testColor spaceThresholdingHough transformlaw.inventionScleramedicine.anatomical_structurelawRegion of interestmedicineCanny edge detectorComputer visionArtificial intelligencebusinessHueMathematics
researchProduct