Search results for "VOLUME"

showing 10 items of 1932 documents

Corrected whole blood biomarkers - the equation of Dill and Costill revisited.

2018

Abstract An exercise bout or a dehydration often causes a reduction in plasma volume, which should be acknowledged when considering the change in biomarkers before and after the plasma changing event. The classic equation from Dill and Costill (1974, J. Appl. Physiol., 37, 247–248) for plasma volume shift is usually utilized in such a case. Although this works well with plasma and serum biomarkers, we argue in this note that this traditional approach gives misleading results in the context of whole blood biomarkers, such as lactate, white cells, and thrombocytes. In this study, we demonstrate that to calculate the change in the total amount of circulating whole blood biomarker, one should u…

medicine.medical_specialtyPhysiologyContext (language use)030204 cardiovascular system & hematologyPlasma volumeta311103 medical and health sciencesHemoglobins0302 clinical medicineSerum biomarkersPhysiology (medical)Internal medicineMembrane PhysiologymedicineHumansplasma changePlasma Volumeta315Exercisecorrection formulaWhole bloodOriginal ResearchDehydrationbusiness.industryEndurance and PerformanceDill and Costill equationveri030229 sport sciencesBiomarkerEndocrinologymarkkeritBiomarker (medicine)veriplasmaHemoglobinsense organsCellular PhysiologybusinessAlgorithmsBiomarkersPhysiological reports
researchProduct

Resistance Training with Single vs. Multi-joint Exercises at Equal Total Load Volume: Effects on Body Composition, Cardiorespiratory Fitness, and Mus…

2017

The present study aimed to compare the effects of equal-volume resistance training performed with single-joint (SJ) or multi-joint exercises (MJ) on VO2max, muscle strength and body composition in physically active males. Thirty-six participants were divided in two groups: SJ group (n = 18, 182.1 ± 5.2, 80.03 ± 2.78 kg, 23.5 ± 2.7 years) exercised with only SJ exercises (e.g., dumbbell fly, knee extension, etc.) and MJ group (n = 18, 185.3 ± 3.6 cm, 80.69 ± 2.98 kg, 25.5 ± 3.8 years) with only MJ exercises (e.g., bench press, squat, etc.). The total work volume (repetitions × sets × load) was equated between groups. Training was performed three times a week for 8 weeks. Before and after the…

medicine.medical_specialtyPhysiologySquatAerobic capacity; Fat loss; Muscle strength; Resistance exercise; Strength training; Physiology; Physiology (medical)Bench presslcsh:Physiology03 medical and health sciences0302 clinical medicinePhysiology (medical)strength trainingMedicinefat lossOriginal ResearchAerobic capacity Fat loss Muscle strength Resistance exercise Strength trainingSettore M-EDF/02 - Metodi E Didattiche Delle Attivita' Sportivelcsh:QP1-981Multi jointbusiness.industryResistance trainingVO2 maxCardiorespiratory fitness030229 sport sciencesaerobic capacityresistance exerciseVolume (thermodynamics)Muscle strengthPhysical therapymuscle strengthbusinessSettore M-EDF/01 - Metodi E Didattiche Delle Attivita' Motoriehuman activities030217 neurology & neurosurgeryFrontiers in physiology
researchProduct

Doctor, quiero una talla 100

2009

Cuando una paciente consulta al cirujano plástico con la intención de que éste le efectúe una mamoplastia de aumento es, en la mayoría de las ocasiones, difícil interpretar exactamente el volumen que desea. La determinación del volumen de la mama que posee la paciente y del volumen que quisiera tener se ve limitada por inconvenientes técnicos y por la poca precisión en la interpretación psicosocial de las mediciones y cálculos que se pueden hacer. El objetivo de este estudio ha sido desarrollar un sistema que partiendo de las medidas intrínsecas del sujetador permita relacionar el volumen de la mama de la paciente con el volumen de la copa del sujetador que desea y con la prótesis necesaria…

medicine.medical_specialtyPlastic surgeryPrótesis mamariasbusiness.industrymedicineBreast volumeSurgeryskin and connective tissue diseasesbusinessMamoplastia de AumentoBreast augmentationSurgery
researchProduct

Editorial: CBCT special issue

2014

In the dental community, it is a common belief that CBCT was invented for oral and maxillofacial imaging. Of course, we know that this is a myth since the technique of a volumetric CT is indeed much older and dates back to the late 1970s.1,2 Considering that CT was introduced in 1973, its volumetric counterpart was developed very soon thereafter driven by the need for high spatial and temporal resolution that a conventional CT at that time was not able to achieve. However, successful marketing of the technique indeed was much later, and certainly a consequence of the publication of “A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results” by Mozz…

medicine.medical_specialtyPoint (typography)business.industryPeer ReviewRadiation doseDental imagingCBCT Special Issue: EditorialSubject (documents)General MedicineCone-Beam Computed TomographyCbct imagingImaging Three-DimensionalOtorhinolaryngologySubsequent revisionVolumetric CTRadiography DentalMedicineHumansRadiology Nuclear Medicine and imagingReview processMedical physicsbusinessGeneral Dentistry
researchProduct

A new approach using high volume blood patch for prevention of post-dural puncture headache following intrathecal catheter pump exchange.

2015

Background: In an observational study, complications of intrathecal catheter pumps necessitating surgical exchange were analyzed. Also the use of a high-volume prophylactic epidural blood patch (EBP) during surgery for preventing post-dural puncture headache (PDPH) with a follow-up for 1 year is described. Materials and Methods: In 22 patients with refractory chronic pain of cancer/noncancer origin or severe spasticity, who were receiving intrathecal morphine including adjuvants or baclofen for symptom relief, catheter exchange with or without pump was performed. In patients with documented symptoms of PDPH following initial intrathecal catheter implantation, a prophylactic EBP with a high …

medicine.medical_specialtyPost-dural-puncture headacheBlood volumeCritical Care and Intensive Care Medicinepost-dural puncture headacheMedicineIntrathecal pumpFunctional abilityddc:610Epidural blood patchintrathecal catheterbusiness.industryPublic Health Environmental and Occupational HealthChronic painEpidural blood patchmedicine.diseaseEpidural spaceSurgeryCathetermedicine.anatomical_structureintrathecal pumpAnesthesiaEmergency MedicineOriginal Articlemedicine.symptombusiness
researchProduct

Value of serial magnetic resonance imaging in the assessment of brain metastases volume control during stereotactic radiosurgery

2016

AIM To evaluate brain metastases volume control capabilities of stereotactic radiosurgery (SRS) through serial magnetic resonance (MR) imaging follow-up. METHODS MR examinations of 54 brain metastases in 31 patients before and after SRS were reviewed. Patients were included in this study if they had a pre-treatment MR examination and serial follow-up MR examinations at 6 wk, 9 wk, 12 wk, and 12 mo after SRS. The metastasis volume change was categorized at each follow-up as increased (> 20% of the initial volume), stable (± 20% of the initial volume) or decreased (< 20% of the initial volume). RESULTS A local tumor control with a significant (P < 0.05) volume decrease was observed in 25 meta…

medicine.medical_specialtyPseudo progressionBrain metastasemedicine.medical_treatmentPseudo-progressionVolume controlRadiosurgery03 medical and health sciencesMagnetic resonance imaging0302 clinical medicineRetrospective StudymedicineStereotactic radiosurgerymedicine.diagnostic_testbusiness.industryBrain metastasesMagnetic resonance imagingequipment and suppliesRadiation therapyRadiation therapySerial magnetic resonance imaging030220 oncology & carcinogenesisRadiologyNuclear medicinebusinesshuman activities030217 neurology & neurosurgeryWorld Journal of Radiology
researchProduct

Metabolic control of respiratory neuronal activity and the accompanying changes in breathing movements of the rabbit

1976

Expiratory-related neurons have been classified according to their phase relation within the respiratory cycle, their response to lung distension and collapse (α- and β-type), and to hyperventilation (tonic firing denoted by “+”, cessation of activity by “−”). The dorsal surface of the medulla oblongata was superfused with a metabolite-containing CSF solution and the activity of expiratory (E) and inspiratory-expiratory (IE) neurons was extracellularly recorded. The neuronal sub-types established by their functional behaviour could equally be distinguished by their differential response to one or several metabolites. In contrast to inspiratory (I) neurons, E − α , E + β , E − β and IE − β n…

medicine.medical_specialtyRespiratory ratePhysiologyClinical BiochemistryBiologyEndocrinologyPhysiology (medical)Internal medicineAnesthesiaHyperventilationmedicineMedulla oblongataBreathingPremovement neuronal activityRespiratory systemmedicine.symptomReceptorTidal volumePfl�gers Archiv European Journal of Physiology
researchProduct

Rapid hemodilution induced by desmopressin after erythropoietin administration in humans

2011

We have shown that treatment with desmopressin has a very effective hemodilution effect in healthy humans. These results led us to suggest the possible role of desmopressin to mask blood doping in sports. Based on our results, the World Anti-Doping Agency included the desmopressin in the 2011 List of Prohibited Substances and Methods. On this occasion, the aim of our study was to test the desmopressin-induced hemodilution after rHuEpo administration in humans. This was an intra-subject, crossover study in which five physically active males acted as their own controls. A basal blood sample was taken on their first visit to the laboratory. The next day, the subjects began the treatment. They …

medicine.medical_specialtyReticulocytesPLASMA VOLUME EXPANDERS[SDV]Life Sciences [q-bio]Physical Therapy Sports Therapy and RehabilitationHematocrit01 natural sciences03 medical and health sciences0302 clinical medicineBlood dopingInternal medicinemedicineEducación Física y DeportivaHaematocritHemoglobinSTIMULATION INDEXlcsh:Sports medicineDesmopressinHEMOGLOBINmedicine.diagnostic_testbusiness.industry010401 analytical chemistryPlasma volume expanders030229 sport sciencesCrossover study3. Good health0104 chemical sciencesStimulation index and plasma volume expandersEndocrinologyBasal (medicine)HematocritErythropoietinAnesthesiaHemoglobinHEMATOCRITHaemoglobinbusinesslcsh:RC1200-1245hormones hormone substitutes and hormone antagonistsmedicine.drugJournal of Human Sport and Exercise
researchProduct

Compromised Lung Volume and Hemostatic Abnormalities in COVID-19 Pneumonia: Results from an Observational Study on 510 Consecutive Patients

2021

Background: Hemostatic abnormalities have been described in COVID-19, and pulmonary microthrombosis was consistently found at autopsy with concomitant severe lung damage. Methods: This is a retrospective observational cross-sectional study including consecutive patients with COVID-19 pneumonia who underwent unenhanced chest CT upon admittance at the emergency room (ER) in one large academic hospital. QCT was used for the calculation of compromised lung volume (%CL). Clinical data were retrieved from patients’ files. Laboratory data were obtained upon presentation at the ER. Aim: The aim of this study was to evaluate the correlation between hemostatic abnormalities and lung involvement in pa…

medicine.medical_specialtySARS-CoV-2 pneumonia610 Medicine & health2700 General Medicine030204 cardiovascular system & hematologyLung injuryGastroenterologyArticlelung volume measurements03 medical and health sciences0302 clinical medicineInternal medicineD-dimerMedicineLung volumesCOVIDLungbusiness.industry10031 Clinic for AngiologyRCOVID-19General MedicineOdds ratiomedicine.diseasePneumoniamedicine.anatomical_structure030220 oncology & carcinogenesisHemostasisConcomitantD-dimerhemostasisMedicinebusiness
researchProduct

Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik

2005

Purpose To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. Materials and methods Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using …

medicine.medical_specialtyShort axisVentricular functionmedicine.diagnostic_testbusiness.industryPhase contrast microscopySignificant differenceMagnetic resonance imagingBlood flowlaw.inventionSurgeryVolume (thermodynamics)Flow (mathematics)Paired sampleslawmedicine.arteryAscending aortaLeft ventricular Stroke volumeMedicineRadiology Nuclear Medicine and imagingSystolebusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct