Search results for "VOLUME"

showing 10 items of 1932 documents

A Multipurpose Instrument To Measure the Vitreous Properties of Charged Colloidal Solids

2001

We present a new high-precision light-scattering setup to study the properties of colloidal solids. It combines static light scattering, dynamic light scattering, and torsional resonance spectroscopy with a flexible and reliable preparational procedure. All three experiments can be performed quasi-simultaneously on the same mechanically undisturbed sample. Thus, unequivocal identification of glassy behavior in a comprehensive characterization dependent on interaction parameters becomes possible. A detailed description of the mechanics is given. We thoroughly tested the new apparatus on dilute colloidal samples and against commercial reference instruments. We performed a first systematic ser…

Chemistrybusiness.industryLight scatteringCharged particleSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsCharacterization (materials science)BiomaterialsColloid and Surface ChemistryOpticsDynamic light scatteringChemical physicsVolume fractionMeasuring instrumentStatic light scatteringbusinessSpectroscopyJournal of Colloid and Interface Science
researchProduct

Molecular Features Behind Formation of α or β Co-Crystalline and Nanoporous-Crystalline Phases of PPO

2022

Guest molecular features determining the formation of α and β phases of poly(2-6-dimethyl-1,4-phenylene) oxide (PPO) are explored by collecting literature data and adding many new film preparations, both by solution casting and by guest sorption in amorphous films. Independently of the considered preparation method, the α-form is favored by the hydrophobic and bulky guest molecules, while the hydrophilic and small guest molecules favor the β-form. Furthermore, molecular modeling studies indicate that the β-form inducer guests establish stronger dispersive interactions with the PPO units than the α-form inducer guests. Thus, the achievement of co-crystalline (and derived nanoporous crystalli…

Chemistrydispersive energy calculationsdispersive energy calculationDFT calculationguest molecular volumeGeneral ChemistryDFT calculationsQD1-999solubility parametersguest solubility in waterFrontiers in Chemistry
researchProduct

An overview of the analytical methods for the determination of organic ultraviolet filters in biological fluids and tissues.

2012

Organic UV filters are chemical compounds added to cosmetic sunscreen products in order to protect users from UV solar radiation. The need of broad-spectrum protection to avoid the deleterious effects of solar radiation has triggered a trend in the cosmetic market of including these compounds not only in those exclusively designed for sun protection but also in all types of cosmetic products. Different studies have shown that organic UV filters can be absorbed through the skin after topical application, further metabolized in the body and eventually excreted or bioaccumulated. These percutaneous absorption processes may result in various adverse health effects, such as genotoxicity caused b…

Chemistrymedicine.disease_causeBiochemistryAnalytical ChemistryBody FluidsMatrix (chemical analysis)Adverse health effectEnvironmental chemistryPercutaneous absorptionmedicineBiological fluidsEnvironmental ChemistryAnimalsHumansSample preparationTissue DistributionOrganic ChemicalsSpectroscopyGenotoxicityUltravioletVolume concentrationAnalytica chimica acta
researchProduct

Stationary phase modulation in liquid chromatography through the serial coupling of columns: A review

2016

Liquid chromatography with single columns often does not succeed in the analysis of complex samples, in terms of resolution and analysis time. A relatively simple solution to enhance chromatographic resolution is the modulation of the stationary phase through the serial coupling of columns. This can be implemented with any type of column using compatible elution conditions and conventional instruments. This review describes the key features of column coupling and published procedures, where two or more columns were coupled in series to solve separation problems. In all reports, the authors could not resolve their samples with single columns, whereas significant enhancement in chromatographi…

Chromatography010405 organic chemistryChemistryElution010401 analytical chemistryKey features01 natural sciencesBiochemistryMass spectrometricDead volume0104 chemical sciencesAnalytical ChemistryVolumetric flow rateTwo-dimensional chromatographyStationary phaseEnvironmental ChemistryChromatography columnSpectroscopyAnalytica Chimica Acta
researchProduct

Effect of tetrahydrofuran on the conductance and ion-pairing of hydrogen chloride in wet and dry methanol mixtures

1995

The molar conductance of dilute solutions of HCl in wet (68.5% methanol + 31.5% tetrahydrofurane mixtures at 25°C have been measured. The data were analyzed using the Fuoss-Hsia equation to calculate the infinite dilution molar conductances and association constants. The trend of the limiting conductances in these mixtures as a function of the water content shows, once more, the peculiar minimum due to the anomalous proton conductance mechanism. From these data the limiting molar conductance in the anhydrous binary solvent system was evaluated. The percentage excess proton mobility with respect to potassium ion has also been determined. All these data are compared to those found in a binary…

ChromatographyAqueous solutionBiophysicsAnalytical chemistryConductanceMole fractionBiochemistryDilutionSolventchemistry.chemical_compoundMolar volumechemistryMethanolBinary systemPhysical and Theoretical ChemistryMolecular BiologyJournal of Solution Chemistry
researchProduct

Channel flow at an immobilised liquid|liquid interface

2000

A novel rectangular channel flow electrochemical cell for the study of liquid | liquid interfaces is presented. The organic phase is immobilised by the use of a gelling agent, while the aqueous phase flows past the interface. This creates an asymmetric setup that allows us to establish diagnostic criteria to determine, for example, the direction of the ion transfer. The effects of varying flow rate and sweep rate have been considered both theoretically and experimentally. By comparison with two-dimensional simulations, it is demonstrated that a simple one-dimensional theory can be used to describe the cyclic voltammetry response of the channel flow cell.

ChromatographyAqueous solutionChemistryGeneral Chemical EngineeringAqueous two-phase systemMechanicsAnalytical ChemistryOpen-channel flowElectrochemical cellVolumetric flow ratePhysics::Fluid DynamicsPhase (matter)ElectrochemistryITIESCyclic voltammetryJournal of Electroanalytical Chemistry
researchProduct

Volumes and compressibilities of pentanol in aqueous dodecyltrimethylammonium bromide solutions at 15, 25 and 35°C

1990

Ultrasonic velocities and densities of the water-dodecyltrimethylammonium bromide (DTAB)-pentanol (PentOH) ternary system were measured at 15, 25 and 35°C as a function of the surfactant and alcohol concentrations. The apparent molar volumes and isentropic compressibilities of PentOH were calculated. The standard partial molar volumes increase with surfactant concentration continuously whereas the standard partial molar isentropic compressibilities show sharp changes in slope at about 0.25 mol-kg−1 DTAB, which can be ascribed to a micellar structural transition. The volume data for alcohol in micellar solutions were treated by a model reported for the distribution of polar additives between…

ChromatographyAqueous solutionIsentropic processChemistryDistribution constantBiophysicsConcentration effectThermodynamicsBiochemistryMicelleMolar volumePulmonary surfactantMicellar solutionsPhysical and Theoretical ChemistryMolecular BiologyJournal of Solution Chemistry
researchProduct

Abatement of Acid Orange 7 in macro and micro reactors. Effect of the electrocatalytic route

2014

Abstract The electrochemical treatment of aqueous solutions contaminated by Acid Orange 7 (AO7) was widely studied with the main objective to evaluate as the electrocatalytic route affects the performances of the degradation process in macro and microfluidic cells. Direct anodic oxidation (EO), electro-Fenton (EF), electro-generation of active chlorine (IOAC) and coupled processes were investigated in macro and microfluidic reactors in order to select more effective conditions for the treatment of such compound. The effect of numerous operative parameters (such as nature of the electrode materials, coupling of processes, flow rate, current density and inter-electrode distance) on the perfor…

ChromatographyAqueous solutionSupporting electrolyteChemistryProcess Chemistry and TechnologyElectrocatalysiElectrochemistryElectrocatalystCatalysisCatalysisVolumetric flow rateChemical engineeringMass transferActive chlorineAcid Orange 7Electro-FentonMicroreactorMicro reactorBDDGeneral Environmental Science
researchProduct

Solution Properties of Polyelectrolytes. VI. Secondary Effects in Aqueous Size-Exclusion Chromatography

1990

Abstract An independent analysis of different operational variables in aqueous size exclusion chromatography of poly electrolytes has been carried out using a silica-based support. The effect of polyion concentration, pH and ionic strength on sodium polystyrenesulfonate calibration plots has been investigated. Finally, a novel semi-empirical model has been developed from thermodynamic considerations which relates the support effective pore volume to the polyelectrolyte molecular weight and qualitatively describes secondary effects.

ChromatographyAqueous solutionVolume (thermodynamics)Ionic strengthChemistrySodiumSize-exclusion chromatographyMolecular Medicinechemistry.chemical_elementElectrolytePolyelectrolyteJournal of Liquid Chromatography
researchProduct

Synchronized gradient elution in capillary liquid chromatography

2013

Abstract The synchronization of injection valve operation and gradient elution in capillary liquid chromatography (cHPLC) is studied. Focus is placed on the cHPLC systems which rely on the splitting of a primary flow to provide the much smaller secondary flow required at the injection device and analytical column. Owing to the tiny secondary flow rates, synchronization is necessary to achieve proper optimization of gradient elution methods. Otherwise, there is a risk of having the analytes totally or partially eluted in the initial isocratic conditions, and there is no control on the actual gradient profile reaching the column. Synchronization is first achieved by switching back the valve t…

ChromatographyCapillary actionElutionChemistryOrganic ChemistryMixing (process engineering)Analytical chemistryBenzeneGeneral MedicineInjectorSecondary flowBiochemistryAnalytical Chemistrylaw.inventionSynchronization (alternating current)Volume (thermodynamics)lawSpark plugChromatography High Pressure LiquidJournal of Chromatography A
researchProduct