Search results for "Valve replacement"
showing 10 items of 78 documents
Inhaled Prostacyclin, Nitric Oxide, and Nitroprusside in Pulmonary Hypertension After Mitral Valve Replacement
2005
Abstract Objective: Pulmonary hypertension increases morbidity and mortality in patients undergoing heart surgery. Mitral valve stenosis is frequently associated with an increase in pulmonary vascular resistance (PVR). Cardiopulmonary bypass exacerbates pulmonary hypertension in patients undergoing cardiac surgery. The aim of this study was to compare the hemodynamic effects of inhaled prostacyclin and nitric oxide and the administration of i.v. nitroprusside during cardiac surgery with a clinical, pharmacodynamic dose-response, prospective, randomized, and double-blind study (Group A: inhaled prostacyclin; Group B: inhaled nitric oxide; Group C: nitroprusside). Materials and Methods: Fifty…
Non-sutureless minimally invasive aortic valve replacement: mini-sternotomy versus mini-thoracotomy: a series of 1130 patients
2016
Objectives Aortic valve replacement through conventional sternotomy still represents the gold-standard surgical approach for aortic valve disease. However, given the increasing number of patients with comorbidities, strategies that can improve operative results are always sought. Minimally invasive aortic valve surgery, although related to a steep learning curve, might be associated with improved postoperative outcomes. The main aim of this study was to assess whether significant differences exist in terms of operative and early results between a mini-sternotomy and a right mini-thoracotomy approach for isolated aortic valve replacement without sutureless technologies. Methods This is an ob…
Outcomes of Patients With Asymptomatic Aortic Stenosis Followed Up in Heart Valve Clinics
2018
International audience; Importance - The natural history and the management of patients with asymptomatic aortic stenosis (AS) have not been fully examined in the current era. Objective - To determine the clinical outcomes of patients with asymptomatic AS using data from the Heart Valve Clinic International Database. Design, setting, and participants - This registry was assembled by merging data from prospectively gathered institutional databases from 10 heart valve clinics in Europe, Canada, and the United States. Asymptomatic patients with an aortic valve area of 1.5 cm2 or less and preserved left ventricular ejection fraction (LVEF) greater than 50% at entry were considered for the prese…
Modified Danielson Technique for Prosthetic Aortic Valve Endocarditis and Aortoventricular Discontinuity
2020
Endocarditis is a devastating complication of prosthetic aortic valve replacement. The infective process can destroy aortic annulus tissue, making conventional surgical valve replacement difficult or impossible and causing aortoventricular discontinuity. Several treatment techniques have been proposed. One of these, the Danielson technique, involves translocating the aortic valve to the native ascending aorta, débriding the abscess cavity, closing the coronary ostia, and bypassing the coronary arteries with a Y anastomosis between 2 vein grafts. We describe our use of a modified Danielson technique in a 68-year-old man with advanced prosthetic valve endocarditis that was associated with aor…
Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences
2011
OBJECTIVES: The purpose is to evaluate in vivo at rest and under stress conditions hemodynamic performance of the small size St. Jude Medical Regent (SJMR) prosthetic valve in patients with a body surface area (BSA) of 1.8 ± 0.11 m(2) and to define the role of valve prosthesis- patient mismatch on left ventricular mass regression following aortic valve replacement. METHODS: We evaluated 25 cases (12 males and 13 females, mean age 65.2 ± 8 years) of aortic valve replacement (17 mm SJMR in three cases and 19 mm SJMR in 22 cases). All the patients underwent at rest Doppler echocardiography before and after surgery and both basal and dobutamine stress echocardiography (DSE) at follow-up. The me…
Short-term and long-term results of cardiac surgery in elderly and very elderly patients
2011
Objective: Cardiac operations in elderly patients are increasingly frequent and imply major clinical, ethical, and economic issues. Operative and 5-year results of cardiac operations in patients aged 79 years or more are known in limited series, and a debate is ongoing on the appropriateness of selection of patients for surgery. Methods: We retrospectively reviewed our experience in 6802 patients aged 79 years or more who had received a cardiac operation. Surgical candidates were selected according to functional status, crude operative risk, and social context and were managed according to a multimodality protocol. Results: Mean age was 82 years and surgery was nonelective in 1613 cases (23…
ECG-GATED MULTIDETECTOR COMPUTED TOMOGRAPHY FOR THE ASSESSMENT OF THE POSTOPERATIVE ASCENDING AORTA
2009
This study was undertaken to define the role of electrocardiographically (ECG)-gated multidetector computed tomography (MDCT) in the assessment of the postoperative ascending aorta. From November 2006 to June 2007, 21 patients, [11 men, ten women; age +/- standard deviation (SD): 62.7 +/- 10.8 years] with a history of ascending aorta replacement underwent ECG-gated MDCT and were prospectively included in our study. Ascending aorta replacement had been performed with different surgical techniques: Bentall-De Bono (four patients, 19%), Tirone-David (five patients, 23%), and modified Tirone-David with creation of aortic neosinuses (12 patients, 57%). Two patients were excluded from MDCT evalua…
Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
2013
Background— Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results— Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters an…
Gerbode-type left ventricular outflow tract to right atrial fistula complicating prosthetic aortic valve replacement identified by cardiac computed t…
2012
Abstract Acquired left ventricular-right atrial communication ( Gerbode-type defect) is a rare complication of infective endocarditis. Although transesophageal echocardiography remains the technique of choice for the evaluation of complications of endocarditis this case highlights the usefulness of cardiac computed tomography in this scenario, particularly in cases where assessment of coronary anatomy is required before surgery.
Permanent Pacemaker Lead Insertion Connected to an External Pacemaker Generator for Temporary Pacing After Transcatheter Aortic Valve Implantation.
2019
Abstract Background Outcomes after transcatheter aortic valve implantation (TAVI) have been demonstrated to be at least equivalent in the short term compared to surgical valve implantation (SAVI). However, Conduction abnormalities are more common after TAVI than SAVI and the need for permanent pacemaker implantation is more common after TAVI with the currently commercially available self-expanding valves than after SAVI. Temporary pacemaker implantation may be associated with inability to ambulate, lead migration or perforation and infection. Depending on the monitoring system, some arrhythmias may not be detected. We examined the feasibility and safety of permanent pacemaker lead implantat…