Search results for "Ventricle"
showing 10 items of 431 documents
MR imaging of the heart in patients after myocardial infarction: effect of increasing intersection gap on measurements of left ventricular volume, ej…
1999
International audience; Abstract: PURPOSE: To determine the extent to which the number of planes imaged at magnetic resonance (MR) imaging could be reduced without modifying the volume and thickness of the left ventricle. MATERIALS AND METHODS: Sixty-one patients were examined after a myocardial infarction. The whole left ventricle was imaged by using 5-mm contiguous breath-hold cine MR short-axis sections with no gap (SA(ng)) (two-dimensional fast low-angle shot sequence, 9/4.8 [repetition time msec/echo time msec]). The effect of omitting in two (short-axis sections with 5-mm gap [SA(5mm)]) or two sections in three(short-axis sections with 10-mm gap [SA(10mm)]) was studied. RESULTS: In th…
ICD implantation in noncompaction of the left ventricular myocardium: a case report
2009
Isolated noncompaction of the ventricular myocardium (INVM) is an uncommon cardiomyopathy characterized by the persistence of fetal myocardium with prominent trabecular meshwork and deep intertrabecular recesses, often associated with systolic dysfunction and ventricular dilatation. A 23-year-old man from Burkina Faso was referred to our operative unit with a diagnosis of INVM, made with echocardiogram and magnetic resonance imaging and nonsustained ventricular tachycardia. The literature reports the incidence of malignant ventricular arrhythmias in as many as 47% of the patients and sudden cardiac death in almost 50% of them and this supported our decision to perform implantable cardiovert…
Information transfer in QT-RR dynamics: Application to QT-correction
2018
ABSTRACTThe relation between the electrical properties of the heart and the beating rate is essential for the heart functioning. This relation is central when calculating the “corrected QT interval” — an important measure of the risk of potentially lethal arrhythmias. We use the transfer entropy method from information theory to quantitatively study the mutual dynamics of the ventricular action potential duration (the QT interval) and the length of the beat-to-beat (RR) interval. We show that for healthy individuals there is a strong asymmetry in the information transfer: the information flow from RR to QT dominates over the opposite flow (from QT to RR), i.e. QT depends on RR to a larger e…
Positive inotropic response to 5-HT in human atrial but not in ventricular heart muscle
1992
The effects of 5-hydroxytryptamine (5-HT) on force of contraction (FC), action potential (AP) and calcium current (ICa) were studied in human right atrial and left ventricular heart muscle. 5-HT exerted a concentration-dependent increase in FC in multicellular atrial preparations; the EC50 was approximately 3 x 10(-7) mol/l. Maximal increases in FC (252 +/- 58% of control values; mean +/- SEM, n = 6) were obtained at 5-HT 10(-5) mol/l. At this concentration, ICa was increased four- to sevenfold in enzymatically isolated atrial myocytes. In contrast, ventricular preparations did not respond to 5-HT; FC, AP and ICa remained unaffected. In the same preparations, FC was increased by isoprenalin…
Multislice multiecho T2* cardiac magnetic resonance for the detection of heterogeneous myocardial iron distribution in thalassaemia patients
2009
The present study investigated myocardial T2* heterogeneity in thalassaemia major (TM) patients by cardiac magnetic resonance (CMR), to determine whether is related to inhomogeneous iron overload distribution. A total of 230 TM patients consecutively referred to our laboratory were studied retrospectively. Three short-axis views (basal, medium and apical) of the left ventricle (LV) were obtained by multislice multiecho T2* CMR. T2* segmental distribution was mapped on a 16-segment LV model. The level of heterogeneity of the T2* segmental distribution, evaluated by the coefficient of variation (CoV), was compared with that of a surrogate data set, to determine whether the inhomogeneous segme…
Evaluation of the efficacy of oral deferiprone in beta-thalassemia major by multislice multiecho T2*.
2006
Objectives: Oral deferiprone (L1) appears to be promising in the treatment of beta-thalassemia major (TM) patients. T2* magnetic resonance imaging (MRI) with a single measurement in the mid-ventricular septum was validated as a quantitative evaluation of myocardial iron overload. Previous studies suggested a marked heterogeneity of iron distribution in the myocardium. We set up a multislice multiecho T2* MRI for the detection of this heterogeneity. The aim of our study was to investigate differences between the L1 vs. the subcutaneous desferrioxamine (DF)-treated patients using this new approach.Methods: Thirty-six beta-TM patients (age 29 +/- 8 yr) underwent MRI. Eighteen patients received…
Multislice multiecho T2* cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload.
2006
Purpose To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibili…
Endoscopic Neurosurgery and Endoscope-assisted Microneurosurgery for the Treatment of Intracranial Cysts
1998
Objective Different endoscopic techniques have been introduced into neurosurgery, but accepted terminology and definitions are still missing. We propose a terminology based on whether the endoscope is used alone or in conjunction with an operating microscope and on whether the route of surgical manipulations is through or outside the endoscope. Accordingly, procedures are categorized into endoscopic neurosurgery (EN), endoscope-assisted microneurosurgery (EAM), and endoscope-controlled microneurosurgery (ECM). Methods We treated 36 patients with intracranial arachnoid cysts (ACs) and intraventricular cysts endoscopically. The patients ranged in age from 4 months to 69 years (mean age, 31 yr…
Endoscope-assisted microsurgery for tumors of the septum pellucidum: surgical considerations and benefits of the method in the treatment of four seri…
2003
Neoplasms that primarily originate from the septum pellucidum are extremely rare. Generally the septum pellucidum is involved in direct extension of tumors that arise from the neighboring structures, principally the corpus callosum. Endoscope-assisted techniques form a useful adjunct to common microsurgical procedures to completely remove intraventricular lesions. There are two main advantages of endoscope-assisted surgery over common microsurgical techniques: reduction of superficial brain retraction with less iatrogenic trauma to the neighboring structures and inspection of hidden corners depict simultaneously anatomical details which are not precisely visible in the zoomed and thus light…
Transthoracic three-dimensional echocardiographic volumetry of distorted left ventricles using rotational scanning
1997
The purpose of this study was to evaluate the relation of transthoracic three- and two-dimensional echocardiographic left ventricular volumetry to cineventriculographic volumetry. Twenty-five patients with distorted left ventricles were included in the study. To demonstrate the impact of acquiring data by rotational scanning, we performed three- and two-dimensional echocardiography in 36 latex ventricles with data acquisition in different areas of the ultrasound sectors. Interobserver and intraobserver variability were calculated to test for reproducibility. The three-dimensional imaging system consisted of a rotation motor device, a transthoracic 2.5 MHz transducer, a conventional ultrasou…