Search results for "Vessel"

showing 10 items of 751 documents

Right coronary artery arising from pulmonary trunk: assessment with conventional coronary angiography and multislice computed tomography coronary ang…

2009

We present a case of a 59-year-old man who was admitted to the hospital because of atypical chest pain and dyspnea. Conventional coronary angiography showed an anomalous origin of the right coronary artery from the pulmonary trunk. The patient underwent multislice computed tomography in order to clarify the origin and course of the anomalous vessel. The aim of this report is to emphasize the role of multislice computed tomography as an accurate noninvasive imaging tool in the evaluation of coronary artery anomalies.

Coronary angiographyRight coronary arteryMalemedicine.medical_specialtyCoronary Vessel AnomaliesContrast MediaPulmonary ArteryCoronary AngiographyIopamidolAngina PectorisPredictive Value of Testsmedicine.arterymedicineHumansPulmonary Trunkbusiness.industryGeneral MedicineMultislice computed tomographyMiddle AgedIopamidolmedicine.anatomical_structureDyspneaRight coronary arteryPredictive value of testsPulmonary arteryRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedArterymedicine.drugJournal of cardiovascular medicine (Hagerstown, Md.)
researchProduct

Response by Meneveau and Ecarnot to Letter Regarding Article, “Optical Coherence Tomography to Optimize Results of Percutaneous Coronary Intervention…

2017

We read with interest the letters by Vallurupalli and Uretsky and also Dr Nadir relating to the results of the DOCTORS study (Does Optical Coherence Tomography Optimize Results of Stenting).1 We thank the authors for their insightful remarks. Vallurupalli and Uretsky raise an interesting point when they underline that a prolonged inflation time is superior to a rapid inflation/deflation technique in terms of both stent expansion and apposition. We acknowledge that we did not take stent inflation time into account in the case report form of the DOCTORS study. The arguments put forward by Vallurupalli and Uretsky suggest that this variable should be systematically recorded and reported. Howev…

Coronary angiographymedicine.medical_specialtyAcute coronary syndromemedicine.medical_treatment030204 cardiovascular system & hematologyCoronary Angiography03 medical and health sciencesPercutaneous Coronary Intervention0302 clinical medicineOptical coherence tomographyPhysiology (medical)medicineHumansMedical physicsIn patient030212 general & internal medicineAcute Coronary SyndromeCase report formmedicine.diagnostic_testbusiness.industryST elevationPercutaneous coronary interventionStentmedicine.diseaseCoronary VesselsSurgeryTreatment OutcomeStentsCardiology and Cardiovascular MedicinebusinessTomography Optical CoherenceCirculation
researchProduct

Anatomical variants and anomalies of the coronary tree studied with MDCT coronary angiography

2010

Le anomalie delle arterie coronariche sono presenti alla nascita nella maggior parte dei casi asintomatiche ma possono manifestarsi con sintomatologia severa quale angina pectoris o addirittura l’arresto cardiaco. L’angiografia coronarica mediante tomografia computerizzata multistrato (TCMS) permette, tramite ricostruzioni multiplanari secondo piani curvilinei e riformattazioni 3D, la visualizzazione dell’albero coronarico e delle sue varianti ed anomalie in maniera non invasiva, fornendo migliore e più accurata alternativa alla angiografia coronarica (AC). Lo scopo di questo pictorial consiste nella descrizione mediante immagini TCMS con ricostruzioni multiplanari e 3D delle principali var…

Coronary angiographymedicine.medical_specialtyFistulaCoronary anomaliesCoronary Vessel AnomaliesFistulaAsymptomaticAnginaImaging Three-DimensionalHumansMedicineRadiology Nuclear Medicine and imagingcardiovascular diseasesNeuroradiologyCoronary variantsmedicine.diagnostic_testbusiness.industryMDCTInterventional radiologyGeneral Medicinemedicine.diseaseMiocardial bridgingRadiographic Image EnhancementCoronary arteriesmedicine.anatomical_structurecardiovascular systemTomographyRadiologymedicine.symptomcoronary angiographyTomography X-Ray ComputedbusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaMDCT; coronary angiography; Coronary anomalies; Coronary variants; Miocardial bridging; FistulaMDCT coronary angiography Coronary anomalies Coronary variants Miocardial bridging Fistula
researchProduct

SYNTAX score is associated with in-hospital mortality as assessed by GRACE risk score in patients with acute myocardial infarction

2013

Coronary angiographymedicine.medical_specialtyFramingham Risk ScoreIn hospital mortalitybusiness.industryCoronary arteriosclerosisHospital mortalitymedicine.diseaseInternal medicineMedicineIn patientMyocardial infarctionMedical emergencyCardiology and Cardiovascular MedicineMulti vessel coronary artery diseasebusinessEuropean Heart Journal
researchProduct

Long-term outcome of patients with NSTEMI and nonobstructive coronary arteries by different angiographic subtypes

2021

Discordant data have been reported on the prognosis of myocardial infarction with nonobstructive coronary arteries (MINOCA). Moreover, few data are available on the impact of angiographic subtypes. The objectives of this study were to assess the prognostic impact on the long-term follow-up of the diagnosis of MINOCA and its angiographic subtypes.We included 591 consecutive patients with non-ST-segment elevation myocardial infarction (NSTEMI) who underwent coronary angiography. MINOCA was classified according to angiographic findings as smooth coronary arteries, mild irregularities (30% stenosis), and moderate atherosclerosis (30%-49% stenosis). The primary endpoint was a composite of mortal…

Coronary angiographymedicine.medical_specialtyMultivariate analysismedicine.medical_treatmentMyocardial Infarction030204 cardiovascular system & hematologyCoronary AngiographyRevascularization03 medical and health sciences0302 clinical medicineInternal medicinemedicineHumansMyocardial infarctionNon-ST Elevated Myocardial Infarctionbusiness.industryGeneral Medicinemedicine.diseaseCoronary VesselsIndependent factorCoronary arteriesmedicine.anatomical_structureCardiologyST Elevation Myocardial InfarctionbusinessMaceRevista Española de Cardiología (English Edition)
researchProduct

Heart Failure: Really Idiopathic?

2016

Coronary angiography is necessary in the differential diagnosis of a newly discovered heart failure, which may be caused by multivessel disease and/or stenoses of major vessels. However, angiography is associated with a relatively high percentage of false negative findings in the assessment of left main disease. FFR allows unveiling these false negatives, even though special precautions need to be taken when stenoses are present also in the bifurcation branches.

Coronary angiographymedicine.medical_specialtymedicine.diagnostic_testbusiness.industrynutritional and metabolic diseasesMultivessel diseasemedicine.diseaseInternal medicineHeart failureAngiographymedicineCardiologyDifferential diagnosisbusinessLeft main disease
researchProduct

2017

We propose a mesh-free and discrete (particle-based) multi-physics approach for modelling the hydrodynamics in flexible biological valves. In the first part of this study, the method is successfully validated against both traditional modelling techniques and experimental data. In the second part, it is further developed to account for the formation of solid aggregates in the flow and at the membrane surface. Simulations of various types of aggregates highlight the main benefits of discrete multi-physics and indicate the potential of this approach for coupling the hydrodynamics with phenomena such as clotting and calcification in biological valves.

CouplingMultidisciplinaryAggregate (data warehouse)Blood flow01 natural sciencesMesh free010305 fluids & plasmas010101 applied mathematicsFlow (mathematics)Blood vessel prosthesis0103 physical sciencesFluid dynamics0101 mathematicsMembrane surfaceBiological systemPLOS ONE
researchProduct

Measurement of Head Motion during Double-Poling Technique in Cross-Country Ski Classical Race using Kinematic GNSS

2019

Cross countryGNSS applicationsPolingHead (vessel)Motion (geometry)KinematicsGeodesyGeologyThe Proceedings of the Symposium on sports and human dynamics
researchProduct

Automatic Extraction of Blood Vessels, Bifurcations and End Points in the Retinal Vascular Tree

2008

In this paper we present an effective algorithm for automated extraction of the vascular tree in retinal images, including bifurcations, crossovers and end-points detection. Correct identification of these features in the ocular fundus helps the diagnosis of important systematic diseases, such as diabetes and hypertension. The pre-processing consists in artefacts removal based on anisotropic diffusion filter. Then a matched filter is applied to enhance blood vessels. The filter uses a full adaptive kernel because each vessel has a proper orientation and thickness. The kernel of the filter needs to be rotated for all possible directions. As a consequence, a suitable kernel has been designed …

Cross-correlationPixelAnisotropic Diffusion Matched Filter Retinal Vessels ROC curve.Computer scienceAnisotropic diffusionbusiness.industryQuantitative Biology::Tissues and OrgansMatched filterBinary imageComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONRetinalPattern recognitionchemistry.chemical_compoundTree structurechemistryKernel (image processing)Artificial intelligencebusiness
researchProduct

An improved goniometer head for high-temperature single-crystal X-ray diffraction

1999

A reliable and inexpensive goniometer head has been designed. Its stability, resulting from its compact construction, makes it very suitable for accurate measurements. Moreover, its space-saving design facilitates its application in X-ray data collection using charge-coupled device (CCD) detectors. This head has been improved for high-temperature measurements and has been tested by comparison of accurate K0.88Rb0.12TiOPO4data collected both at room temperature and at 973 K on the same crystal. The excellent structure results obtained at 973 K during the 360 h of measurements prove the stability of the goniometer head.

CrystalCrystallographyOpticsbusiness.industryChemistryGoniometerDetectorX-ray crystallographyHead (vessel)businessSingle crystalGeneral Biochemistry Genetics and Molecular BiologyJournal of Applied Crystallography
researchProduct