Search results for "Visual Acuity"

showing 10 items of 456 documents

Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism

2017

Purpose: To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. Methods: A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period wa…

Malemedicine.medical_specialtyKeratoconusCorneal Wavefront AberrationVisual acuityCorneal ectasiagenetic structuresContact LensesVisual AcuityAstigmatismKeratoconusCornea03 medical and health sciences0302 clinical medicineProsthesis FittingOphthalmologyCorneamedicineHumansHigh orderIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyEye Diseases HereditaryCorneoscleral contact lensGeneral MedicineMiddle Agedmedicine.diseaseCorneal topographyeye diseasesOphthalmologyHyperopiamedicine.anatomical_structureEye examination030221 ophthalmology & optometrysense organsmedicine.symptombusinessSclera030217 neurology & neurosurgeryOptometry
researchProduct

Optociliary veins and central retinal vein occlusion.

1993

In a follow up of 94 patients with central retinal vein occlusion (CRVO) whose onset had taken place less than 1 year earlier, optociliary veins (OCVs) were found in 7.4% at first examination. Among the 79 eyes in which the fundus of the eye was very visible after a follow up of more than 1 year OCVs were found in 30.4%, showing a late development of OCVs in many cases of CRVO. No difference was found in the occurrence of OCVs between non-ischaemic and ischaemic forms of CRVO. The visual acuity of the eyes with CRVO that developed OCVs was not significantly different from the visual acuity of the eyes without OCVs. Thus, the presence of OCVs in CRVO does not seem to be associated with bette…

Malemedicine.medical_specialtyLate developmentVisual acuityTime Factorsgenetic structuresAdolescentEye diseaseOptic DiskOptic diskVisual AcuityCellular and Molecular NeuroscienceCentral retinal vein occlusionIschemiaOphthalmologyRetinal Vein OcclusionmedicineHumansFluorescein AngiographyAgedmedicine.diagnostic_testbusiness.industryVascular diseaseMiddle Agedmedicine.diseaseFluorescein angiographyPrognosisSensory Systemseye diseasesSurgeryOphthalmologyFemalemedicine.symptombusinessRetinopathyResearch Article
researchProduct

Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery.

2007

Purpose To determine whether implantation of a microincision intraocular lens (IOL) with a modified anterior surface, designed to compensate for the positive spherical aberration of the cornea in eyes of cataract patients, results in improved pseudophakic quality of vision in pseudophakic eyes after biaxial microincision phacoemulsification. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods In a nonrandomized parallel cohort investigation, the visual performance of 52 eyes of 52 patients unilaterally implanted with the aspherical Acri.Smart 36 A IOL (Acri.Tec) were compared with those of 25 eyes of 25 age-matched patients unilaterally implanted with…

Malemedicine.medical_specialtyMicrosurgerygenetic structuresPseudophakiaMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularCorneaOphthalmologymedicineContrast (vision)HumansProspective StudiesCapsulorhexismedia_commonAgedLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationCataract surgeryMiddle Agedeye diseasesSensory SystemsSurgeryOphthalmologySpherical aberrationmedicine.anatomical_structureSurgeryFemalesense organsbusinessJournal of cataract and refractive surgery
researchProduct

Factors predicting normal visual acuity following anatomically successful macular hole surgery

2021

Purpose: To assess the incidence of normal vision following anatomically successful macular hole surgery and associated clinical variables. Methods: Multicentre, retrospective chart review. Preoperative, intraoperative and postoperative clinical data were extracted from electronic medical records from seven European vitreoretinal units. Inclusion criteria were as follows: eyes undergoing primary vitrectomy for idiopathic full-thickness macular hole from January 2015 to January 2018; postoperative macular hole closure confirmed by spectral domain optical coherence tomography (OCT); preoperative pseudophakia or phakic eyes receiving combined cataract surgery; one-year follow-up. The primary o…

Malemedicine.medical_specialtyMultivariate analysisVisual acuitygenetic structuresPseudophakiamacular hole closuremedicine.medical_treatmentVisual AcuityvitrectomyVitrectomyTime-to-Treatment03 medical and health sciences0302 clinical medicinefull-thickness macular hole; idiopathic macular hole; macular hole closure; macular hole surgery; vitrectomymedicineFull-thickness macular holeHumansMacular holeAgedRetrospective Studiesfull-thickness macular holeidiopathic macular holebusiness.industryGeneral MedicineOdds ratioCataract surgeryMiddle Agedmedicine.diseaseRetinal Perforationseye diseasesConfidence intervalSurgeryOphthalmologyTreatment Outcomemacular hole surgery030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryTomography Optical CoherenceFollow-Up Studies
researchProduct

Lack of effect of intraocular lens asphericity on visual performance with acrylic intraocular lenses.

2011

Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and…

Malemedicine.medical_specialtyOptics and PhotonicsVisual acuityMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityLens Implantation IntraocularOphthalmologyMedicineContrast (vision)Humansmedia_commonAgedAged 80 and overLenses Intraocularbusiness.industryStrehl ratioGeneral MedicineMiddle AgedOphthalmologySpherical aberrationFemalemedicine.symptombusinessPhotopic visionEuropean journal of ophthalmology
researchProduct

PHOTODYNAMIC THERAPY WITH VERTEPORFIN FOR CHOROIDAL NEOVASCULARIZATION ASSOCIATED WITH RETINAL PIGMENT EPITHELIAL DETACHMENT IN AGE-RELATED MACULAR D…

2007

Abstract PURPOSE: To assess the effectiveness of photodynamic therapy (PDT) with verteporfin for choroidal neovascularization (CNV) associated with retinal pigment epithelium detachment (PED) in age-related macular degeneration. METHODS: Thirty eyes of 26 patients with CNV and PED were treated with PDT. The eyes were divided in two groups based on CNV location in relation to PED; group 1 included 13 eyes with CNV within PED, and group 2 included 17 eyes with CNV at the edge of PED. The median follow-up was 16 months. RESULTS: Patients received a mean +/- SD of 2.83 +/- 1.26 treatments (range, 1-6 treatments). In the whole cohort, the mean preoperative visual acuity changed from 20/144 (0.86…

Malemedicine.medical_specialtyPorphyrinsVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityPhotodynamic therapyMacular DegenerationAge relatedOphthalmologymedicineHumansProspective StudiesFluorescein AngiographyPigment Epithelium of EyeAgedAged 80 and overPhotosensitizing AgentsRetinal pigment epitheliumSettore MED/30 - Malattie Apparato Visivobusiness.industryRetinal DetachmentVerteporfinGeneral MedicineMiddle AgedMacular degenerationmedicine.diseaseVerteporfinChoroidal Neovascularizationeye diseasesOphthalmologyTreatment Outcomemedicine.anatomical_structureChoroidal neovascularizationPhotochemotherapyFemaleRetinal pigment epithelial detachmentsense organsPhotodynamic therapy choroidal neovascularization age-related macular degenerationmedicine.symptombusinessFollow-Up Studiesmedicine.drugRetina
researchProduct

Clinical Outcome and Subjective Quality of Life after Photodynamic Therapy in Patients with Age-Related Macular Degeneration

2005

PURPOSE. Whereas the efficacy of photodynamic therapy (PDT) in preventing the progression of age-related macular degeneration (ARMD) is established, its effect on quality of life is under discussion. METHODS. All patientswho underwent PDT during 2000 and 2001 at the University Eye Hospital of Mainz were interviewed using a standardized 82-item questionnaire on quality of life and patient satisfaction in ophthalmologic patients. Information was assessed in terms of 82 questions; global scores ranging from 1.0 (optimum self-estimated quality of life) to 4.0 (worst) were derived. Cataract patients' scores were used to characterize the ARMD patients' subjective outcome; the latter were then rel…

Malemedicine.medical_specialtyPorphyrinsVisual acuitymedicine.medical_treatmentVisual AcuityPsychological interventionPhotodynamic therapyLogistic regressionMacular Degeneration03 medical and health sciences0302 clinical medicinePatient satisfactionQuality of lifeSurveys and QuestionnairesInternal medicineActivities of Daily LivingmedicineHumansIn patientAgedRetrospective StudiesAged 80 and overPhotosensitizing Agentsbusiness.industryVerteporfinGeneral MedicineMacular degenerationmedicine.diseaseChoroidal Neovascularizationeye diseasesOphthalmologyCross-Sectional StudiesTreatment OutcomePhotochemotherapyPatient SatisfactionQuality of Life030221 ophthalmology & optometryPhysical therapyFemalemedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Impact of lens material on objective refraction in eyes with trifocal diffractive intraocular lenses

2021

Purpose: Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Methods: Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M…

Malemedicine.medical_specialtyPseudophakiaMesopic visionmedicine.medical_treatmentVisual AcuityUlls -- Acomodació i refraccióIntraocular lensRefraction OcularIntraocular lensesPupillaw.invention03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicinelawOphthalmologymedicineHumansPostoperative PeriodProspective StudiesMathematicsAgedEye -- Accomodation and refractionVision BinocularIntraocular lensOpticsTrifocal diffractiveLents intraocularsHydrofilicRefractionSubjective refractionMultifocal Intraocular LensesSensory SystemsLens (optics)OphthalmologyRefractionAutorefractorPatient SatisfactionDifracció030221 ophthalmology & optometryFemale:Ciències de la visió [Àrees temàtiques de la UPC]Diffraction030217 neurology & neurosurgeryHydrofobicPhotopic visionFollow-Up Studies
researchProduct

Non-infectious uveitis burden on quality of life and work impairment assessed through different psychometric questionnaires

2021

Background: The purpose of this study was to evaluate the association between a novel psychometric 12-item questionnaire (U-qest) and other validated questionnaires to assess quality of life and work impairment in patients with non-infectious uveitis. Methods: Data were collected at baseline and 3 months postbaseline using U-qest and two other validated questionnaires: The National Eye Institute 25-Item Visual Function Questionnaire (VFQ-25) and the 12-Item Short-Form Health Survey (SF-12). Results: A total of 136 patients (52.2% female) aged 47.9 ± 14.8 years (mean ± SD) were enrolled in 14 uveitis referral centres. U-qest correlated moderately with VFQ-25 and SF-12 at baseline and at 3 mo…

Malemedicine.medical_specialtyQoLPsychometricsReferralVisual Acuityuveitis questionnaire; QoL; disease burden; work impairmentDiseaseAffect (psychology)Uveitisdisease burdenInfectious uveitisQuality of lifeCronbach's alphawork impairmentSurveys and QuestionnairesmedicineHumansDisease burdenbusiness.industryReproducibility of ResultsGeneral Medicinemedicine.diseaseOphthalmologyQoL; Uveitis questionnaire; disease burden; work impairmentQuality of LifePhysical therapydisease burden QoL Uveitis questionnaire work impairmentFemalebusinessUveitis questionnaireUveitisuveitis questionnaire
researchProduct

Relationship among Corneal Biomechanics, Refractive Error, and Axial Length

2014

Purpose To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickne…

Malemedicine.medical_specialtyRefractive errorIntraocular pressureocular parametersAdolescentgenetic structuresAnterior ChamberVisual AcuityEmmetropiaCorneachildrenOphthalmologyHumansMedicinerefractive errorChildIntraocular PressureDioptreÓpticabusiness.industryBiomechanicsHigh myopiaAxial lengthElastic TissueRefractive Errorsmedicine.diseaseeye diseasesBiomechanical PhenomenaAxial Length EyeOphthalmologyCross-Sectional Studiesagecorneal biomechanical propertiesRegression AnalysisOptometryFemaleMultiple linear regression analysissense organsbusinessTomography Optical CoherenceOptometryOptometry and Vision Science
researchProduct