Search results for "Volt"

showing 10 items of 2187 documents

Determination of the Boron/Lead Ratio in Ceramic Materials Based on Electrochemical Quartz Crystal Microbalance

2004

A method for quantitatively determining the relationship boron/lead in ceramic materials is presented. It is based on the attachment of microsamples of ceramic frits to an electrochemical quartz crystal microbalance (EQCM). After a reductive deposition step in the � 0.25 to � 0.85 V (vs. AgCl/Ag) potential range, well-defined stripping peaks are recorded in 0.10 M NaCl plus 0.10 M mannitol. The deposition of boron and lead from suspensions of solid materials, and its subsequent oxidative dissolution can be monitorized at the EQCM. The quotient between the maximum mass gain and the corresponding charge passed enables for a direct quantitation of the boron/lead molar ratio in ceramic material…

inorganic chemicalsMaterials scienceStripping (chemistry)chemistry.chemical_elementQuartz crystal microbalanceCeramic materialsElectrochemistryAnalytical Chemistrychemistryvisual_artElectrochemistryvisual_art.visual_art_mediumDeposition (phase transition)CeramicBoronVoltammetryDissolutionElectroanalysis
researchProduct

The effect of oxygenation on the radiation hardness of silicon studied by surface photovoltage method

2002

The effect of oxygenation on the radiation hardness of silicon detectors was studied. Oxygen-enriched and standard float-zone silicon pin-diodes and oxidized samples were processed and irradiated with 15-MeV protons. After the irradiations, the surface photovoltage (SPV) method was applied to extract minority carrier diffusion lengths of the silicon samples. Adding oxygen to silicon was found to improve the radiation hardness of silicon. The effect was visible in minority carrier diffusion lengths as well as in reverse bias leakage currents. The suitability of SPV method for characterizing irradiated silicon samples was proved.

inorganic chemicalsNuclear and High Energy PhysicsMaterials scienceSiliconPhysics::Instrumentation and Detectorsbusiness.industrySurface photovoltageDetectortechnology industry and agriculturechemistry.chemical_elementCarrier lifetimeequipment and suppliescomplex mixturesOxygenstomatognathic diseasesNuclear Energy and EngineeringchemistryOptoelectronicsIrradiationElectrical and Electronic EngineeringbusinessRadiation hardeningLeakage (electronics)IEEE Transactions on Nuclear Science
researchProduct

Annealing study of oxygenated and non-oxygenated float zone silicon irradiated with protons

2003

Abstract Introducing oxygen into the silicon material is believed to improve the radiation hardness of silicon detectors. In this study, oxygenated and non-oxygenated silicon samples were processed and irradiated with 15 MeV protons. In order to speed up the defect reactions after the exposure to particle radiation, the samples were heat treated at elevated temperatures. In this way, the long-term stability of silicon detectors in hostile radiation environment could be estimated. Current–voltage measurements and Surface Photovoltage (SPV) method were used to characterize the samples.

inorganic chemicalsPhysicsNuclear and High Energy PhysicsSiliconPhysics::Instrumentation and Detectorsbusiness.industryAnnealing (metallurgy)Surface photovoltagetechnology industry and agricultureAnalytical chemistrychemistry.chemical_elementRadiationFloat-zone siliconequipment and suppliescomplex mixtureschemistryOptoelectronicsIrradiationParticle radiationbusinessInstrumentationRadiation hardeningNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Determination of toxic elements by cathodic-stripping-voltammetry

1981

The DPCSV determination of arsenic, selenium and tellurium in the sub-ng/ml range is discussed. After electrolytic deposition of the elements as intermetallic compounds with copper on the electrode surface, the determination is carried out by cathodic stripping. The simultaneous determination of selenium and tellurium or of selenium and arsenic is possible. Problems which occur in the application of these methods are discussed.

inorganic chemicalsStripping (chemistry)Inorganic chemistryIntermetallicfood and beverageschemistry.chemical_elementCopperAnalytical ChemistryCathodic protectionchemistryCathodic stripping voltammetryTelluriumArsenicSeleniumMikrochimica Acta
researchProduct

Molecular basis of early epithelial response to streptococcal exotoxin: role of STIM1 and Orai1 proteins

2011

Streptolysin O (SLO) is a cholesterol-dependent cytolysin (CDC) from Streptococcus pyogenes. SLO induces diverse types of Ca(2+) signalling in host cells which play a key role in membrane repair and cell fate determination. The mechanisms behind SLO-induced Ca(2+) signalling remain poorly understood. Here, we show that in NCI-H441 cells, wild-type SLO as well as non-pore-forming mutant induces long-lasting intracellular Ca(2+) oscillations via IP(3) -mediated depletion of intracellular stores and activation of store-operated Ca(2+) (SOC) entry. SLO-induced activation of SOC entry was confirmed by Ca(2+) add-back experiments, pharmacologically and by overexpression as well as silencing of ST…

inorganic chemicalsVoltage-dependent calcium channelORAI1ImmunologyBiologyMicrobiologyCell biologyCell membranemedicine.anatomical_structureMembrane proteinVirologymedicineStreptolysinsense organsCytolysinIntracellularCalcium signalingCellular Microbiology
researchProduct

Metrological performances of voltage and current instrument transformers in harmonics measurements

2018

In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by usin…

instrument transformers020209 energy02 engineering and technologyInstrument TransformerHarmonic analysispower system meaurementsPhase AngleDistortionharmonics0202 electrical engineering electronic engineering information engineeringCalibrationElectronic engineeringMedicineSafety Risk Reliability and QualityInstrumentationbusiness.industry020208 electrical & electronic engineeringHarmonicPower System MeasurementcalibrationCurrent transformerMetrologyHarmonicsHarmonicbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Current transformers effects on the measurement of harmonic active power in LV and MV networks

2011

The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …

instrument transformersEngineeringVoltage and current harmonicsSwitched-mode power supplyAcousticsActive powerTransducersEnergy Engineering and Power TechnologyLinear currentsPower factorHarmonic powerLinear transducersPower errorsPower transformersVoltage transducersHarmonic analysisHarmonic analysisMaximum valuesCurrent transformerElectrical and Electronic EngineeringPower measurementPhase anglesAbsolute valuesHarmonic power flowTotal harmonic distortionbusiness.industryElectric power distributionCurrent harmonicsElectrical engineeringAC powerCurrent transformerMV networksHarmonicsAccuracy classElectric instrument transformersHarmonicPower system harmonicsCurrent transformers (CTs) instrument transformerspower measurement power system harmonics.businessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Results on performance and ageing of solar modules based on Elkem Solar Silicon (ESS™) from installations at various locations

2014

Abstract The present study aims to present the current status of the results obtained using Elkem Solar Silicon (ESS™) as feedstock basis for solar cell and modules. It is shown that solar cells based on ESS™ are able to follow the development of the solar industry obtaining comparable efficiencies to standard polysilicon based cells. The characteristics of ESS™ based solar cells, having normally higher V oc and FF and lower I sc , seem to give clear advantages in the field for solar modules located at high irradiance areas. Results from several locations show enhanced electricity production of ESS™ based solar modules compared to polysilicon at increasing solar irradiance. This is explaine…

integumentary systemSiliconRenewable Energy Sustainability and the Environmentbusiness.industryHigh irradiancefood and beverageschemistry.chemical_elementSolar irradianceEngineering physicsSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialslaw.inventionPhotovoltaic thermal hybrid solar collectorElectricity generationSolar cell efficiencyOpticschemistrySolar industrylawbiological sciencesSolar cellEnvironmental sciencebusinessSolar Energy Materials and Solar Cells
researchProduct

MIGLIORAMENTO TECNOLOGICO-PRESTAZIONALE DI UN COMPONENTE INNOVATIVO PER L’INVOLUCRO EDILIZIO - PERFOMANCE IMPROVEMENT OF AN INNOVATIVE BUILDING COMPO…

2016

L’articolo illustra l’attività di ricerca che gli autori, cofounder della SBskin. Smart Building Skin s.r.l., start up innovativa e spin off accademico dell’Università degli Studi di Palermo, stanno conducendo al fine di ottimizzare le performance energetiche di un componente innovativo per facciate e coperture di edifici (dagli stessi brevettato) in grado di ridurre i consumi energetici e di produrre energia pulita dal sole. L’attività che qui si illustra è stata finalizzata all’ottimizzazione del design dei sub-componenti che contribuiscono alla realizzazione dei pannelli traslucidi multifunzionali (realizzati con vetromattoni innovativi, preassemblati a secco e precompressi) ed alla scel…

involucro edilizio vetromattone efficienza energetica fotovoltaico componenti traslucidi innovazione trasferimento tecnologico spin offSettore ICAR/10 - Architettura Tecnicabuilding envelope glass block energy efficiency photovoltaics translucent components innovation technology transfer spin off
researchProduct

Design and Realization of a Bidirectional Full Bridge Converter with Improved Modulation Strategies

2020

In this paper a Full-Bridge Converter (FBC) for bidirectional power transfer is presented. The proposed FBC is an isolated DC-DC bidirectional converter, connected to a double voltage source&mdash

isolated DC-DC bidirectional converterComputer Networks and CommunicationsComputer science020209 energylcsh:TK7800-836002 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettrici7. Clean energySettore ING-INF/01 - Elettronicafull-bridge converterlaw.inventionFull bridge converterlaw0202 electrical engineering electronic engineering information engineeringElectronic engineeringMaximum power transfer theoremElectrical and Electronic EngineeringTransformerfull-bridge converter; isolated DC-DC bidirectional converter; phase shift modulation; supercapacitorssupercapacitors020208 electrical & electronic engineeringlcsh:Electronicsphase shift modulationHardware and ArchitectureControl and Systems EngineeringSignal ProcessingVoltageElectronics
researchProduct