Search results for "Volt"
showing 10 items of 2187 documents
A Compensation Based Method to Model PV Nodes in Backward/Forward Distribution Network Analysis
2007
PurposeThis paper proposes to identify a new model of the fixed voltage nodes (PV nodes) for medium voltage distribution systems analysis. The model is used within backward/forward (b/f) analysis method applied to solve radial and weakly meshed systems.Design/methodology/approachThe model is based on the compensation currents method for multi‐port systems which has been extensively used, within b/f analysis methods, to take into account the presence of meshes and PV nodes.FindingsTest results prove the approach to be more efficient and precise than previous methodologies and put into evidence the good performance of the proposed model in terms of speed and convergence properties.Research li…
Simple Circuit Models for Studying Global Earthing Systems
2007
The paper proposes three simple circuit models for the simulation of the behaviour of a global earthing system during different fault events. The models allow one the evaluation of the maximum earth potential rise at every possible fault location and for every possible fault event. The three considered fault events are: single-line-to-earth fault inside a MV/LV substation, double-earth-fault in a MV line, single-line-to-earth fault inside a HV/MV station. After having illustrated the hypotheses at the basis of the study, the circuit models for the three fault events are presented and a numerical example shows how to use them in order to check the "global safety" of the interconnected earthi…
Experimental investigation on PLC signal crossing of power transformers
2014
In this work the use of PLC in MV-LV networks is investigated, by means of experimental tests in the case of a two-ways MV/LV communication between two secondary substations. The two substations are connected by a MV overhead power line. Moreover each substation has a by-pass connection at MV bus-bars and a MV/LV power transformer. A ST7580 transceiver is used to inject the communication signal. The transceiver is embedded in a new interface device developed by the authors. In the paper the communication issues are introduced and some experimental tests are presented and discussed. Such tests have been carried out in the presence of voltage net, i.e. 24 kV, with the aim to verify the possib…
Electric Power Quality Evaluation in the Presence of Electromagnetic Emissions
2013
The measurements for the assessment of the electric power quality are often carried out in hostile electromagnetic environments. The aim of the paper is analyzing if and how both radiated and conducted electromagnetic emissions can disturb the measurement system used to quantify these disturbances. To achieve the target, an experimental approach is proposed, which, by means of a simple and fast test, allows establishing if the real electromagnetic environment, where power quality analysis is performed, can alter the measurements. © 2013 IEEE.
The Sequential Switching Shunt Maximum Power Regulator and its Application in the Electric Propulsion System of a Spacecraft
2007
This paper describes a baseline solution of a Power Conditioning and Distribution Unit (PCDU) for Electrical Propulsion (EP) systems. The solution adopted uses two high efficiency, low-mass power regulators; a solar array regulator (SAR) based on the classical Sequential Switching Shunt Regulator with Maximum Power Point Tracking (MPPT) capability followed by a step-up converter to achieve the desired regulated bus voltage. This paper focuses on the first part of the PCDU, the Sequential Switching Shunt Maximum Power Regulator (S3MPR). This electrical architecture has been adapted and recently proposed for the Electric Propulsion power system of the European and Japanese Mercury Mission (Be…
Reliability Analysis of a Stand-Alone PV System for the Supply of a Remote Electric Load
2010
The work presents a reliability analysis of a stand-alone photovoltaic system for the supply of electric loads located in remote areas not easily reachable by the low voltage distribution network. The analysis is performed by characterizing the electric load behavior by means of a Montecarlo approach for taking into account the stochastic variability of the electrical energy demand. A Montecarlo approach is used also for evaluating the electricity production of the stand alone photovoltaic system as a function of the hourly solar irradiation of the installation site. The variability both of the load and of the energy production are correlated and the probability that the load can remain uns…
Experimental EMF characterization of a secondary substation
2015
This paper presents the results of the experimental EMC characterization of a new medium/low voltage (MV/LV) secondary substation, which was developed in the framework of the research project "NEW CAB ELARC". It has two MV/LV transformers, with total rated power of 1000 kVA. To perform the experimental characterization, firstly an analysis was performed of the Italian and European standards recommendations. Different approaches were highlighted and the most appropriate procedures were identified for the measurement of the magnetic fields emissions, at power systems frequency (50 Hz) in steady-state conditions. A dedicated test lab was set up for the secondary substation characterization. Th…
Analysis of voltage dips propagation in MV distribution networks by using ATP-EMTP code
2003
In this paper, voltage dips simulation in electric power MV distribution networks by using an improved ATP circuit-breaker model are reported. An equivalent circuit of a MV distribution system is employed. The circuit-breaker is simulated by using a tool written in MODELS language and by arranging a time-variable differential arc-conductance based on the combination of Mayr's and Cassie's equations. The simulations carried out have shown how the amplitude of the voltage dips depends on the type and location of the fault and their duration is strictly related to the circuit-breaker parameters.
Overcoming synchronization issues in wireless technology Partial Discharge measurement
2016
In this paper, several aspects of the fundamentals of wireless Partial Discharge (PD) measurements are first discussed. Then, the relevance of the problem of voltage synchronization in PD wireless diagnosis is outlined. When portable instruments are used for PD detection, the main issue is the voltage measurement at the site where the PD detection is carried out. When such analysis is carried out over shielded cables, the AC (50/60 Hz) voltage reference signal is not easily detectable, while one of the basic parameters for PD diagnosis, the displacement of the inception voltage of the PD as compared to the reference voltage, is not available. Even if highperformance sensors are readily avai…
Integration of distributed on site control actions via combined photovoltaic and solar panels system
2009
A systematic evaluation of the potential energy saving and CO2 emissions reduction on buildings was carried out, when a renewable energy system is locally installed. The exploitation of a combined solar and photovoltaic system and the integration of suitable energy management actions were deeply investigated. A model of these solar and photovoltaic components has been developed and included within a complete house simulator, capable to precisely figure out the daily electric energy consumptions of typical apartments and to measure the positive actions induced by the added renewable energy. Saving up to 40% on the energy consumptions and even more savings on wiring losses seems to be easily …