Impact of integrating photovoltaic based DG on distribution network harmonics
2017
The process of integrating various distributed generation (DG) technologies in power system networks is increasing rapidly in the recent years. One major concern about the integration of DGs is their impact on network harmonics. The aim of this paper is to investigate the effects caused by the integration of photovoltaic DG in distribution networks on system harmonics. The penetration level, number of DG units, and their location are used as parameters in order to verify the effects of DG on system harmonics. Moreover, a study of single and double tuned filters is conducted as harmonics mitigation techniques. Detailed simulations using Matlab/Simulink are inserted in order to explain and ve…
Impedance estimation of FEA's grid in fiji islands by V-I measurement by using the synchronous reference frame-PLL
2017
In recent years there has been a significant increase in distributed renewable energy generation feeding into the grid, with resulting detriment of the stability of the network, since present networks have not been designed for this purpose. To feed-in these renewable energy sources with minimum impact, it is essential to know a few grid parameters (voltage, current, grid impedance) at the point in which power supply is convenient. For this purpose in this paper an algorithm is proposed to obtain the estimated network impedance. This algorithm operates in time domain by a synchronous reference coordinate transformation, it requires only the measurement of the phase voltage with no-load and …
Hybrid passive and communications-based methods for islanding detection in medium and low voltage smart grids
2013
Islanding condition takes place when a distributed generator (DG) continues to power a part of the grid even if power from electric utility is no longer present. Adverse effects of islanding are power quality deterioration, grid-protection interference, equipment damage, and personnel safety hazards. For these reasons, DG systems must detect an islanding condition and immediately disconnect from the grid (anti-islanding protection). This paper proposes an hybrid solution, for both low voltage (LV) and medium voltage (MV) applications, which makes use of passive and communication-based methods for islanding detection. Among the existing communication technologies, the study is focused on pow…
Wind Turbine Mechanical Characteristics and Grid Parameters Influence on the Transient Voltage Stability of a Fixed Speed Wind Turbine
2008
This paper describes the effect of wind turbine mechanical characteristic of construction and grid parameters on the transient voltage stability of a fixed speed wind turbine (FSWT) connected to a simple grid. The model of FSWT has been developed in Matlab/Simulink. Using this model, a three-phase fault is applied close to the wind turbine (WT) and cleared by disconnecting the faulted line. The effects of mechanical construction of WT and of grid parameters on the voltage stability of this simple case are evaluated and discussed. The considered parameters are the inertia coefficient of the WT, the short-circuit power at the connection bus, the hub-generator resonant frequency, the wind spee…
Effects of Electrical Parameters of Induction Generator on the Transient Voltage Stability of a Fixed Speed Wind Turbine
2008
This paper describes the effect of electrical parameters of the induction generator on the transient voltage stability of a fixed speed wind turbine connected to a simple grid; the dynamic behavior of a wind turbine connected to the grid is examined. The model of the fixed speed wind turbine has been developed in the simulation tool Matlab/Simulink. Itpsilas composed by the induction generator, the shaft system, the aerodynamic model of the wind turbine rotor and the pitch control system. Using this model, a three-phases fault is applied close to the wind turbine and cleared by disconnecting the faulted line. The effect of different electrical parameters of the induction generator on the vo…
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…
Finite difference time domain simulation of earth electrodes soil ionisation under lightning surge condition
2008
The non linear effects of soil ionisation on the behaviour of earth electrodes are investigated by a finite difference time domain numerical scheme. A time variable soil resistivity is used in order to simulate the soil breakdown; step by step the resistivity value is controlled by the local instantaneous value of the electric field compared with the electrical strength, fixed for the soil. No a priori hypothesis about the geometrical shape of the ionised zone around the electrodes has to be enforced. Simulation results related to complex earth electrodes of limited extension are reported. The model has been validated by comparing the computed results with data available in technical litera…
A Technique for Power Supply Harmonic Impedance Estimation Using a Controlled Voltage Disturbance
2002
A method for power system impedance estimation is presented. The method employs a power converter to inject a voltage transient onto the supply system. As the technique employs controlled power electronic devices it may be used as a stand alone piece of a portable measurement equipment, or it may be embedded into the functions of an active shunt filter for improved harmonic control. The impedance is estimated through correlation of the measured voltage and current transients. Simulations and experimental results demonstrate the measurement technique is highly accurate and effective.
Post Feed-in Scheme Photovoltaic System Feasibility Evaluation in Italy: Sicilian Case Studies
2014
: Thanks to national energy policies, over recent years the Italian photovoltaic (PV) sector has undergone an extraordinary growth, also affecting the primary sector. In this context, Mediterranean greenhouses are well-adapted to photovoltaic systems because they represent one of the most energy-intensive sectors in agriculture. The Italian feed-in scheme ended at the beginning of 2013, making it necessary to investigate the feasibility of photovoltaic systems devoid of any electricity production-related incentives. In this paper, production cost and profitability analyses of photovoltaic electricity have been conducted, considering Mediterranean solar greenhouses in which, thanks to net me…
A New Solution for Low-Voltage Distributed Generation Interface Protection System
2015
In this paper, a new solution is proposed for the remote monitoring and control of distributed generators (DGs) and energy storage systems (ESSs) connected to low-voltage distribution networks. The proposed system fulfills the in-force standard requirements for the connection of DGs to the utility grid. Moreover, it allows implementing some enhanced functions for the remote control of inverters of DGs and ESSs, not only in terms of disconnection but also in terms of voltage regulation and power shuttering. The proposed solution is based on a new interface protection system and a dedicated secondary substation concentrator, which allows the communication between the distributed system operat…