Search results for "WINE"

showing 10 items of 1468 documents

Transmission of arterial oxygen partial pressure oscillations to the cerebral microcirculation in a porcine model of acute lung injury caused by cycl…

2013

Cyclic recruitment and derecruitment (R/D) play a key role in the pathomechanism of acute lung injury (ALI) leading to respiration-dependent oscillations of arterial partial pressure of oxygen (Pa(O(2))). These Pa(O(2)) oscillations could also be forwarded to the cerebral microcirculation.In 12 pigs, partial pressure of oxygen was measured in the thoracic aorta (Pa(O(2))) and subcortical cerebral tissue (Pbr(O(2))). Cerebral cortical haemoglobin oxygen saturation (Sbr(O(2))), cerebral blood flow (CBF), and peripheral haemoglobin saturation (Sp(O(2))) were assessed by spectroscopy and laser Doppler flowmetry. Measurements at different fractions of inspired oxygen (F(I(O(2)))) were performed …

medicine.medical_specialtySwineAcute Lung Injurychemistry.chemical_elementBlood PressureLung injuryAnesthesia GeneralOxygenMicrocirculationInternal medicinemedicineLaser-Doppler FlowmetryAnimalsLungOxygen saturation (medicine)Ventilators Mechanicalbusiness.industryMicrocirculationHemodynamicsLaser Doppler velocimetryRespiration Artificialrespiratory tract diseasesOxygenOxygen Saturation MeasurementAnesthesiology and Pain MedicineBlood pressurechemistryCerebral blood flowAnesthesiaCerebrovascular CirculationCardiologybusinessBlood Gas Monitoring TranscutaneousBronchoalveolar Lavage FluidCraniotomyBritish journal of anaesthesia
researchProduct

A regenerative 3D scaffold for inguinal hernia repair. MR imaging and histological cross evidence. Qualitative study

2021

Abstract Background Inguinal hernia is a degenerative disease occurring in a high motile surround. Stopping degeneration and promoting tissue regeneration should be the treatment goal. Groin hernias are conventionally managed with static flat meshes, mostly fixated to the delicate inguinal environment. Far from a regenerative effect, the biologic response of conventional hernia meshes is characterized by a foreign body reaction leading to a stiff/shrunken scar plate, which is often the source of unpleasant complications. Recently, a newly engineered 3D device for inguinal hernia repair – ProFlor-has been developed to produce a regenerative biological response. Unlike conventional hernia mes…

medicine.medical_specialtySwineAdipose tissueHernia InguinalGroinProsthesesDegenerative diseaseMagnetic resonance imagingmedicineAnimalsHerniaHerniorrhaphymedicine.diagnostic_testGroinbusiness.industryInguinal herniaMagnetic resonance imagingHistologyGeneral MedicineSurgical Meshmedicine.diseaseInguinal herniamedicine.anatomical_structureHernia genesisPorcine experimental modelSurgeryRadiologyForeign bodybusinessRegenerative scaffolds
researchProduct

A Continuous Suture Anastomosis Outperforms a Simple Interrupted Suture Anastomosis in Esophageal Elongation.

2020

Abstract Introduction Long-gap esophageal atresia represents a distinct entity among the esophageal atresia spectrum. In many patients, achieving a reasonable anastomosis depends on some millimeters of tissue. We aimed to determine what effect the suturing technique would have on esophageal ex vivo elongation as it may determine the strength of a primary anastomosis. Materials and Methods In an analysis of porcine esophagi from animals for slaughter (100–120 days old with a weight of 100–120 kg), we determined esophageal length gain of simple continuous and simple interrupted suture anastomoses subjected to linear traction until linear breaking strength was reached. Statistical power of 80%…

medicine.medical_specialtySwineAnastomosisBreaking strength03 medical and health sciences0302 clinical medicineEsophagus030225 pediatricsTensile StrengthMedicineAnimalsHumansEsophageal Atresiabusiness.industryPrimary anastomosisAnastomosis SurgicalSuture Techniquesmedicine.diseaseConfidence intervalSurgery030220 oncology & carcinogenesisAtresiaPediatrics Perinatology and Child HealthSurgerybusinessContinuous sutureEuropean journal of pediatric surgery : official journal of Austrian Association of Pediatric Surgery ... [et al] = Zeitschrift fur Kinderchirurgie
researchProduct

The influence of the C1-inhibitor BERINERT® and the protein-free haemodialysate ACTIHAEMYL20%® on the evolution of the depth of scald burns in a porc…

1997

Standardized deep partial-thickness burns were inflicted on domestic pigs by scalding 30 per cent of the skin surface for 25 s with 75 degrees C hot water. The animals (n = 18; weight 25-35 kg) were divided into three groups: I, control group (n = 6), Ringer's lactate only; II, haemodialysate group (n = 6), Ringer's lactate and a protein-free haemodialysate of calf-blood (ACTIHAEMYL20%; AH) and III, C1-inhibitor group (n = 6), Ringer's lactate and C1-inhibitor (C1-INH; BERINERT). Skin biopsies were taken at defined time points (4, 28, 52 and 76 h) and investigated histologically. Depth of burn was determined morphometrically after coloration with a modified MTT-staining on frozen sections o…

medicine.medical_specialtySwineComplement C1 Inactivator ProteinsCritical Care and Intensive Care MedicineStatistics NonparametricMicrocirculationC1-inhibitorRandom AllocationReference ValuesBiopsySkin surfacemedicineScaldingAnimalsSkinWound Healingmedicine.diagnostic_testbiologybusiness.industryBiopsy NeedleHistologyGeneral Medicinemedicine.diseaseSurgeryDisease Models AnimalProtein freeAnesthesiaDisease ProgressionEmergency Medicinebiology.proteinActihaemylSurgeryBurnsWound healingbusinessComplement C1 Inhibitor ProteinBurns
researchProduct

Translational development and pre-clinical evaluation of prototype gastrointestinal mock-up devices: only robotic placement of plastic?

2020

Background: The aim of this study was to address the vision of wireless theranostic devices distributed along the gastrointestinal (GI) tract by defining design requirements, developing prototype mock-ups, and establishing a minimally invasive surgical approach for the implantation process. Methods: Questionnaires for contextual analysis and use case scenarios addressing the technical issues of an implantable GI device, a possible scenario for implantation, preparation and calibration of a device, and therapeutic usage by professionals and patients were completed and discussed by an interdisciplinary team of surgeons, engineers, and product designers. Two acute porcine experiments were cond…

medicine.medical_specialtySwineComputer scienceeducation0206 medical engineeringBiomedical Engineering02 engineering and technology01 natural sciencesTranslational Research BiomedicalRobotic Surgical ProceduresmedicineAnimalsMinimally Invasive Surgical ProceduresMedical physics010401 analytical chemistryRobotic Surgical ProceduresEquipment DesignProstheses and ImplantsGeneral Medicineequipment and supplies020601 biomedical engineering0104 chemical sciencesGastrointestinal TractPrinting Three-DimensionalPlasticsClinical evaluationJournal of Medical Engineering & Technology
researchProduct

Microvascular obstruction in the right ventricle in reperfused anterior myocardial infarction. Macroscopic and pathologic evidence in a swine model.

2013

article i nfo Introduction: Data on right ventricular (RV) involvement in anterior myocardial infarction are scarce. The presence of RV microvascular obstruction (MVO) in this context has not been analyzed yet. The aim of the present study was to characterize the presence of MVO in the RV in a controlled experimental swine model of reperfused anterior myocardial infarction. Materials and Methods: Left anterior descending (LAD) artery-perfused area (thioflavin-S staining after selective infusioninLADartery),infarctsize(lackof triphenyltetrazolium-chloride staining) andMVO (lack of thioflavin-S staininginthe core oftheinfarctedarea) inthe RVwere studied.A quantitative(%of theventricularvolume…

medicine.medical_specialtySwineHeart VentriclesMyocardial InfarctionInfarctionContext (language use)chemistry.chemical_compoundEdemaInternal medicinemedicineAnimalsMyocardial infarctionbusiness.industryHematologymedicine.diseaseCoronary VesselsMagnetic Resonance ImagingPathophysiologyStainingmedicine.anatomical_structurechemistryVentricleMicrovesselsCardiologyThioflavinFemalemedicine.symptombusinesshuman activitiesThrombosis research
researchProduct

New applicator improves waterjet dissection quality

2010

Waterjet dissection is accomplished with Helix Hydro-Jet, but a new device with improved operative handling and potentially superior dissection qualities has been developed.Eighty-four fresh cadaveric pig brains were simultaneously cut with Helix Hydro-Jet and Erbejet 2. A commonly used applicator and a new applicator for the Helix Hydro-Jet were directly compared to the new Erbejet 2. Under standardised conditions, different pressure levels were applied to the brain surface without arachnoids. Technical features, cutting depth, tissue damage and differences of applicators were examined.Microscopic analysis of cutting depth revealed different dissection characteristics of both the devices. …

medicine.medical_specialtySwineHydrostatic pressureBrain surfaceDissection (medical)Neurosurgical ProceduresTissue damageHydrostatic PressuremedicineAnimalsNew devicebusiness.industryDissectionBrainEquipment DesignGeneral MedicineSurgical Instrumentsmedicine.diseaseSurgeryArachnoidsModels AnimalSurgeryNeurology (clinical)businessCadaveric spasmBiomedical engineeringBritish Journal of Neurosurgery
researchProduct

Magnetic resonance microscopy and correlative histopathology of the infarcted heart

2019

Altres ajuts:The present study was supported by the EU Joint Programming Initiative 'A Healthy Diet for a Healthy Life' (JPI HDHL INTIMIC-085), Generalitat Valenciana (GV/2018/116), INCLIVA and Universitat de Valencia (program VLC-BIOCLINIC 20-nanomIRM-2016A). Delayed enhancement cardiovascular magnetic resonance (MR) is the gold-standard for non-invasive assessment after myocardial infarction (MI). MR microscopy (MRM) provides a level of detail comparable to the macro objective of light microscopy. We used MRM and correlative histopathology to identify infarct and remote tissue in contrast agent-free multi-sequence MRM in swine MI hearts. One control group (n = 3 swine) and two experimenta…

medicine.medical_specialtySwineMyocardial InfarctionIschemiaCardiologylcsh:MedicineDelayed enhancement030204 cardiovascular system & hematologyArticle030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineAnimalsHumansMyocardial infarctionlcsh:ScienceAcute miMicroscopyMultidisciplinaryintegumentary systemmedicine.diagnostic_testbusiness.industryMagnetic resonance microscopylcsh:RMagnetic resonance imagingDiagnostic markersmedicine.diseaseMagnetic Resonance ImagingDisease Models AnimalInfarcted heartlcsh:QHistopathologyNuclear medicinebusiness
researchProduct

Beyond Magnamosis: A Method to Test Sutureless Esophageal Anastomotic Devices in Living Swine by Creating an Esophageal Bypass Loop for Natural Oral …

2019

Abstract Introduction: Thoracoscopic esophageal atresia repair has become increasingly popular, but is still limited to a few expert centers and has some challenges and shortcomings. One of them ha...

medicine.medical_specialtySwineOperative TimeAnastomosis03 medical and health sciences0302 clinical medicineEnteral NutritionEsophagusOutcome Assessment Health CareMedicineAnimalsHumansEsophageal AtresiaDigestive System Surgical Proceduresbusiness.industryAnastomosis Surgicalmedicine.diseaseSurgeryDisease Models Animal030220 oncology & carcinogenesisAtresiaEsophageal surgeryMagnets030211 gastroenterology & hepatologySurgerybusinessJournal of laparoendoscopicadvanced surgical techniques. Part A
researchProduct

Effects of BIS076 in a model of osteoarthritis induced by anterior cruciate ligament transection in ovariectomised rats

2015

Background Osteoarthritis (OA) is the most frequent articular disease and a leading cause of disability. There is a need for effective treatments able to slow the progression of disease. Some of the available treatments are dietary supplements providing natural components. Recent studies have shown that estrogen deficiency contributes to the pathophysiological events of OA progression. Methods We have used the anterior cruciate ligament transection model of OA in ovariectomised rats to study the effects of BIS076, a new formulation of a natural porcine cartilage extract associated with hydroxyapatite (as a source of calcium) and vitamin D3. Cartilage degradation, proteoglycan depletion and …

medicine.medical_specialtySwineOvariectomyType II collagenOsteoarthritisCartilage Oligomeric Matrix ProteinBIS076DinoprostoneBone remodelingRheumatologyOsteoprotegerinInternal medicineOsteoarthritismedicineAnimalsOrthopedics and Sports MedicineRats WistarVitamin DCollagen Type IIGlycosaminoglycansBone mineralCartilage oligomeric matrix proteinbiologybusiness.industryTissue ExtractsCartilageAnterior Cruciate Ligament InjuriesArticular cartilage damageOsteoarthritis Kneemedicine.diseasePeptide FragmentsSurgeryRatsDisease Models Animalmedicine.anatomical_structureEndocrinologyDurapatiteTreatment Outcomebiology.proteinAnterior cruciate ligament transection modelCytokinesFemaleMatrix Metalloproteinase 3businessOvariectomised ratsBiomarkersResearch ArticleBMC Musculoskeletal Disorders
researchProduct