Search results for "Wastewater treatment"
showing 10 items of 178 documents
Cost-effectiveness analysis of sewer mining versus centralized wastewater treatment: Case study of the Arga river basin, Spain
2015
ABSTRACT:In the context of the EU Water Framework Directive, a Cost-Effectiveness Analysis (CEA) was performed to compare centralized and decentralized wastewater treatment strategies aimed to improve the ecological status of a Spanish river. The implementation of several hybrid membrane bioreactors within the urban framework for sewer mining (SM) was compared with the more common wastewater treatment plant enlargement option. The assessment ranked 6 alternatives based on 12 potential scenarios, aimed at narrowing the uncertainty of the CEA. The cost analysis illustrated that SM is the most expensive option regarding both investment and operation and maintenance costs. However, the effectiv…
Modelling and dynamic simulation of hybrid moving bed biofilm reactors: model concepts and application to a pilot plant.
2011
In the recent years, there has been an increasing interest in the development of hybrid reactors, especially in the up-grading of existing activated sludge plants that are no longer able to comply with concentration limits established by regulatory agencies. In such systems the biomass grows both as suspended flocs and as biofilm. In this way, it is possible to obtain a higher biomass concentration in the reactor, but without any significant increase of the load to the final clarifier. The paper presents the setting-up of a dynamic mathematical model aimed at quantitatively describing the biokinetic processes occurring in a hybrid moving bed biofilm reactor (HMBBR), and, more in general, in…
Global sensitivity analysis in wastewater applications: A comprehensive comparison of different methods
2013
Three global sensitivity analysis (GSA) methods are applied and compared to assess the most relevant processes occurring in wastewater treatment systems. In particular, the Standardised Regression Coefficients, Morris Screening and Extended-FAST methods are applied to a complex integrated membrane bioreactor (MBR) model considering 21 model outputs and 79 model factors. The three methods are applied with numerical settings as suggested in literature. The main objective considered is to classify important factors (factors prioritisation) as well as non-influential factors (factors fixing). The performance is assessed by comparing the most reliable method (Extended-FAST), by means of proposed…
Instrumentation, control, and automation for submerged anaerobic membrane bioreactors
2015
A submerged anaerobic membrane bioreactor (AnMBR) demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON® , Koch Membrane Systems, PUR-PSH31) was designed and operated for urban wastewater treatment. An instrumentation, control, and automation (ICA) system was designed and implemented for proper process performance. Several single-input-single-output (SISO) feedback control loops based on conventional on off and PID algorithms were implemented to control the following operating variables: flow-rates (influent, permeate, sludge recycling and wasting, and recycled biogas through both reactor and membrane tanks), sludge wasting volume, temperature, transmembrane pr…
Productivity of wastewater treatment plants in the Valencia Region of Spain
2017
Abstract This study analyses the evolution of productivity over the 2008–2012 period for a homogenous set of 199 wastewater treatment plants that are located in the Valencia Region of Spain and utilize the same treatment technology, using the smoothed bootstrap Malmquist productivity index based on Data Envelopment Analysis (DEA). The results reveal a negative trend in productivity that is mainly the result of resource management rather than an inappropriate level of innovation or use of new technologies. In addition, the effect of exogenous factors on productivity is analysed using the Kruskal-Wallis (KW) test, finding that productivity levels were affected by the quality of the influent w…
Uncertainty estimation of a complex water quality model: The influence of Box–Cox transformation on Bayesian approaches and comparison with a non-Bay…
2012
Abstract In urban drainage modelling, uncertainty analysis is of undoubted necessity. However, uncertainty analysis in urban water-quality modelling is still in its infancy and only few studies have been carried out. Therefore, several methodological aspects still need to be experienced and clarified especially regarding water quality modelling. The use of the Bayesian approach for uncertainty analysis has been stimulated by its rigorous theoretical framework and by the possibility of evaluating the impact of new knowledge on the modelling predictions. Nevertheless, the Bayesian approach relies on some restrictive hypotheses that are not present in less formal methods like the Generalised L…
Assessment of data and parameter uncertainties in integrated water-quality model
2011
In integrated urban drainage water quality models, due to the fact that integrated approaches are basically a cascade of sub-models (simulating sewer system, wastewater treatment plant and receiving water body), uncertainty produced in one sub-model propagates to the following ones depending on the model structure, the estimation of parameters and the availability and uncertainty of measurements in the different parts of the system. Uncertainty basically propagates throughout a chain of models in which simulation output from upstream models is transferred to the downstream ones as input. The overall uncertainty can differ from the simple sum of uncertainties generated in each sub-model, dep…
Application of the Morris method for screening the influential parameters of fuzzy controllers applied to wastewater treatment plants
2011
In this paper,we evaluate the application of a sensitivity analysis to help fine-tuning a fuzzy controller for a biological nitrogen and phosphorus removal (BNPR) plant. TheMorris Screeningmethod is proposed and evaluated as a prior step to obtain the parameter significance ranking. First, an iterative procedure has been performed in order to find out the proper repetition number of the elementary effects (r) of the method. The optimal repetition number found in this study (r = 60) is in direct contrast to previous applications of the Morris method, which usually use low repetition number, e.g. r = 10 ~ 20. Working with a non-proper repetition number (r) could lead to Type I error (identify…
Monetary valuation of salicylic acid, methylparaben and THCOOH in a Mediterranean coastal wetland through the shadow prices methodology
2018
The presence of pharmaceutical and personal care products and drugs of abuse (PPCPs) in wastewater treatment plants (WWTPs) indicates discharge of the effluent may not be suitable for the ecological balance of water ecosystems, such as wetlands. These PPCPs degrade water quality, considered as an ecosystem service (ES), provoking serious environmental impacts. Assessing the monetary value of PPCPs can be used as a proxy for environmental status of the ES of water quality (ESWQ). Considering PPCPs as non-desirable outputs of WWTPs, the shadow prices methodology has been implemented using directional distance function to measure the environmental avoided cost of removing salicylic acid (SA), …
Reverse electrodialysis performed at pilot plant scale: Evaluation of redox processes and simultaneous generation of electric energy and treatment of…
2017
Abstract This paper describes the experimental campaign carried out with a reverse electrodialysis (RED) demonstration plant (Marsala, Italy) with the main aims of: (i) evaluating the effect of various operating parameters, including the redox processes, on the system performances; (ii) using the plant for the simultaneous generation of electric energy and treatment of wastewater. The prototype (44 × 44 cm2, 500 cell pairs) was tested using both real (brackish water and brine) and artificial solutions. Tests with two different electrode rinse solutions (with or without iron redox couples) were performed. In agreement with the data obtained in the laboratory, the presence of iron ions contri…