Search results for "Wave"

showing 10 items of 6009 documents

On-line microwave oven digestion flame atomic absorption analysis of solid samples

1990

Abstract A manifold has been developed for on-line microwave oven digestion and flame atomic absorption spectrometric (FAAS) determination of metallic elements in solid samples. The use of a closed flow system permits sample treatment before analysis by FAAS, the direct injection of slurries avoids a filtration step and the interconnection of two conventional rotary injection valves allows the rapid introduction of samples and standards. The determination of lead in sewage sludge was employed as a test system for the proposed on-line sample digestion manifold. The procedure has a limit of detection of 0.2 μg Pb g−1.

Detection limitChemistryMicrowave ovenAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionDigestion (alchemy)lawSlurryEnvironmental ChemistrySample preparationAtomic absorption spectroscopySpectroscopyFiltrationSludgeAnalytica Chimica Acta
researchProduct

Hydride generation atomic fluorescence spectrometric determination of ultratraces of selenium and tellurium in cow milk

2003

Abstract A sensitive procedure has been developed for selenium and tellurium determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion. The method provides sensitivity values of 1591 and 997 fluorescence units ng−1 ml−1 with detection limits of 0.005 and 0.015 ng ml−1 for Se and Te, respectively. The application of the developed methodology to the analysis of cow milk samples of the Spanish market evidenced the presence of concentration ranges from 11.1 to 26.0 ng ml−1 for Se, and from 1.04 to 9.7 ng ml−1 for Te having found a good comparability with data obtained after dry-ashing of samples.

Detection limitChromatographyHydrideMicrowave ovenchemistry.chemical_elementBiochemistryAtomic fluorescence spectrometryFluorescenceAnalytical ChemistryCow milkchemistryEnvironmental ChemistryTelluriumSpectroscopySeleniumAnalytica Chimica Acta
researchProduct

Rapid microwave assisted hydrolysis of formetanate

1993

Abstract A fast microwave-assisted hydrolysis procedure has been developed for the derivatization of formetanate previously to the flow-injection spectrophotometric determination of m -aminophenol by reaction with p -aminophenol. Formetanate is quantitatively hydrolyzed with 0.1 M NaOH in 150 s using a closed polyetrafluoroethylene reactor with 115 ml internal volume and a radiation power of 390 W. The above procedure has been applied, as a previous step, for the flow-injection spectrophotometric determination of formetanate in spiked water samples and accurate and precise results have been found. The method permits to obtain a limit of detection of 0.025 mg 1 −1 of formetanate. The relativ…

Detection limitChromatographymedicine.diagnostic_testRelative standard deviationBiochemistryMicrowave assistedAnalytical Chemistrychemistry.chemical_compoundHydrolysischemistryFormetanateSpectrophotometrymedicineEnvironmental ChemistryTrace analysisDerivatizationSpectroscopyAnalytica Chimica Acta
researchProduct

Determination of mercury in dry-fish samples by microwave digestion and flow injection analysis system cold vapor atomic absorption spectrometry

1997

Abstract Flow injection analysis system cold vapor atomic absorption spectrometry (FIAS-CV-AAS) preceded by a wet digestion in a microwave oven, as a method for measuring mercury in fish was studied. The digestion process and conditions of the FIAS (carrier concentration: HCl 3% v v ; reducing agent: SnCl2 2% w v : filling and injection times: 8 and 25 min, respectively; and sample volumes) were optimized. The analytical parameters of the proposed method (detection limit = 7.7 ng/g; precision intraassay = 6.7%; interassay = 14.0%) demonstrates its adequacy and are similar to the ones (detection limit = 19.4 ng/g; precision intraassay = 11.2%; interassay = 15.9%) obtained using a conventiona…

Detection limitFlow injection analysisChemistryMicrowave ovenAnalytical chemistrychemistry.chemical_elementGeneral MedicineAnalytical Chemistrylaw.inventionMercury (element)lawReagentCold vapour atomic fluorescence spectroscopyMicrowave digestionAtomic absorption spectroscopyFood ScienceFood Chemistry
researchProduct

Multicommutation hydride generation atomic fluorescence determination of inorganic tellurium species in milk

2005

Abstract A multicommutated flow system has been developed for hydride generation, atomic fluorescence (HG-AFS) determination of tellurate (Te VI ) and tellurite (Te IV ) in milk samples. After a batch leaching of Te by sonication at room temperature for 10 min with aqua regia, sample slurries in acidic medium were merged with sodium borohydride and HCl to obtain data on Te IV . Another portion of the acidic slurry was mixed with KBr and passed through a reaction coil introduced inside a microwave oven to reduce quantitatively Te VI to Te IV which was analyzed by HG-AFS. The detection limit was 0.57 ng g −1 in the original samples. The linear range obtained was till 4 ng ml −1 and the averag…

Detection limitHydrideMicrowave ovenFluorescence spectrometryAnalytical chemistrychemistry.chemical_elementGeneral MedicineTellurateAnalytical Chemistrychemistry.chemical_compoundchemistryReagentAqua regiaTelluriumFood ScienceFood Chemistry
researchProduct

Multi-element trace determinations in pure alkaline earth fluoride powders by high-resolution ICP-MS using wet-chemical sample preparation and laser …

2003

Four alternative analytical procedures for the determination of ten important trace impurities (Mg, Cr, Fe, Cu, Zn, Sr, Zr, Cd, Ba, and Pb) in pure alkaline earth fluoride powders were applied using high-resolution inductively coupled plasma mass spectrometry (ICP-MS). Two procedures are based on a wet-chemical microwave digestion with boric acid and quantification by the standard addition technique and isotope dilution mass spectrometry (IDMS), respectively. In addition, analyses are also performed by laser ablation as a direct solid sampling technique applying matrix-matched external calibration as well as isotope dilution of the powdered sample. For most elements good agreement between t…

Detection limitLaser ablationChemistryStandard additionAnalytical chemistryAnalytical proceduresSample preparationIsotope dilutionMicrowave digestionBiochemistryInductively coupled plasma mass spectrometryAnalytical ChemistryAnalytical and bioanalytical chemistry
researchProduct

Cylindrical optical microcavities: Basic properties and sensor applications

2011

Abstract A detailed theoretical analysis of the basic properties of whispering-gallery modes (WGM) of thin capillaries is presented. The sensitivity of the resonances, as well as the Q factor is analyzed as a function of the structural parameters of the capillary and the refractive index inside the capillary. A practical application where thin capillaries are used for the measurement of glucose concentration in water is presented as a chemical sensor demonstrator. A best sensitivity of 1.24 nm/% of glucose concentration in water is reported, which corresponds to more than 850 nm/RIU. Additionally, different experimental approaches are discussed to improve the sensitivity and the detection l…

Detection limitMaterials scienceCapillary actionbusiness.industryMicrofluidicsCondensed Matter PhysicsAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsOpticsRefractometerHardware and ArchitectureQ factorElectrical and Electronic EngineeringWhispering-gallery wavebusinessRefractive indexExcitationPhotonics and Nanostructures - Fundamentals and Applications
researchProduct

Microwave-assisted vapour-generation Fourier transform infrared spectrometric determination of carbonate in waters

1998

Abstract A microwave-assisted vapour-generation Fourier transform infrared spectrometric procedure is proposed for the determination of total carbonate in waters. The method is based on the simultaneous injection of 100 μl of sample and 300 μl of 0.1 M nitric acid in a two-channel manifold with a merging zone; a coil located inside a microwave oven encourages the removal of CO 2 . The carbon dioxide is separated from the distilled water employed as carrier by means of gas–liquid separator and is introduced by a nitrogen carrier flow inside a long-path infrared absorption gas cell, from which the corresponding flow analysis recording is registered as a function of time in the wavenumber rang…

Detection limitMicrowave ovenAnalytical chemistryInfrared spectroscopyBiochemistryAnalytical Chemistrychemistry.chemical_compoundsymbols.namesakeFourier transformchemistryDistilled waterNitric acidsymbolsEnvironmental ChemistryCarbonateFourier transform infrared spectroscopySpectroscopyAnalytica Chimica Acta
researchProduct

Determination of mercury in rice by cold vapor atomic fluorescence spectrometry after microwave-assisted digestion.

2010

Abstract A cold vapor atomic fluorescence spectrometry method (CV-AFS) has been developed for the determination of Hg in rice samples at a few ng g−1 concentration level. The method is based on the previous digestion of samples in a microwave oven with HNO3 and H2O2 followed by dilution with water containing KBr/KBrO3 and hydroxylamine and reduction with SnCl2 in HCl using external calibration. The matrix interferences and the effect of nitrogen oxide vapors have been evaluated and the method validated using a certified reference material. The limit of detection of the method was 0.9 ng g−1 with a recovery percentage of 95 ± 4% at an added concentration of 5 ng g−1. The concentration level …

Detection limitMicrowave ovenAnalytical chemistrychemistry.chemical_elementTin CompoundsOryzaHydrogen PeroxideMercuryBiochemistryNitric AcidAnalytical ChemistryDilutionMercury (element)Cold Temperaturechemistry.chemical_compoundHydroxylamineCertified reference materialsSpectrometry FluorescencechemistryEnvironmental ChemistryNitrogen oxideGasesMicrowave digestionMicrowavesSpectroscopyAnalytica chimica acta
researchProduct

GFAAS determination of selenium in infant formulas using a microwave digestion method.

1994

A method for determining the selenium content of infant formulas is proposed. It includes wet digestion with nitric acid and hydrogen peroxide in medium pressure teflon bombs in a microwave oven and determination by graphite furnace atomic absorption spectrometry (GFAAS). The absence of interferences is checked. Values obtained for the limit of detection (19.4 ng/g), precision (RSD = 2.2%) and accuracy by analysis of a reference material show that the method is reliable.

Detection limitMicrowave ovenSpectrophotometry AtomicAnalytical chemistrychemistry.chemical_elementInfantHydrogen PeroxideNitric Acidlaw.inventionchemistry.chemical_compoundSeleniumchemistrylawNitric acidHumansSample preparationInfant FoodMagnesiumMicrowave digestionGraphite furnace atomic absorptionAtomic absorption spectroscopyMicrowavesSeleniumPalladiumFood ScienceDie Nahrung
researchProduct