Search results for "Wave"
showing 10 items of 6009 documents
Computationally efficient dynamical analysis of optically driven injection-locked GaAs FET oscillators
1995
A computer-aided simulation technique for the dynamical analysis of a class of GaAs FET optically-driven injection-locked oscillators (ODILO's) is presented. By combining a measurement-derived nonlinear model of the illuminated transistor with a phasor-domain analysis method, a first-approximation - but phenomenologically complete - differential model of the synchronized oscillator is derived. Since amplitude and phase of waveform evolutions are directly addressed and evaluated in a stroboscopic-time scale, the calculation of the transient response to modulated input signals can be done in a more user-friendly and computationally efficient manner than possible through conventional time-doma…
ANALGESIC EFFECT OF EXTRACORPOREAL SHOCK-WAVE THERAPY ON CHRONIC TENNIS ELBOW
1996
We report a controlled, prospective study to investigate the effect of treatment by low-energy extracorporeal shock waves on pain in tennis elbow. We assigned at random 100 patients who had had symptoms for more than 12 months to two groups to receive low-energy shock-wave therapy. Group I received a total of 3000 impulses of 0.08 mJ/mm2 and group II, the control group, 30 impulses. The patients were reviewed after 3, 6 and 24 weeks. There was significant alleviation of pain and improvement of function after treatment in group I in which there was a good or excellent outcome in 48% and an acceptable result in 42% at the final review, compared with 6% and 24%, respectively, in group II.
Apparent content curves: description and analytical applications. Resolution of binary mixtures
1992
The apparent content curves and their analytical applications are described. Basing on these curves a mathematical method, which permits the identification of the interfering component present in a binary mixture as well as the determination of the contents of both constituents, is proposed. The existence of considerable interaction coefficients is not an impediment for its application. Besides, the analyte contents in the mixture can be obtained without the use of standard interference solutions. The proposed procedure is applied to the analysis of mixtures of dyes with overlapping absorption spectra.
The determination of trace element concentrations in fly ash samples using ultrasound-assisted digestion followed with inductively coupled plasma opt…
2009
Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element (chromium, copper, lead, nickel, vanadium and zinc) concentrations in fly ash samples was developed. All the measurements were performed in robust plasma conditions. Ultrasound-assisted digestion procedures using digestion solutions of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 80% for all the analyte elements. Ultrasound-assisted two-step digestion with digestion solutions of 6 mL of HNO3 (Step 1) and 3 mL of HNO3 + 3 mL of HF (Step 2) resulted in recovery rates of over 92% for all the ana…
Highly Sensitive Detection of Naphthalene in Solvent Vapor Using a Functionalized PBG Refractive Index Sensor
2012
We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 pp…
Hyperbolic subtraction method: Determination of the concentration of an analyte in the presence of an unknown interferent via spectral data.
2018
A theoretical model to determine the concentration of an analyte in the presence of unknown interferents using spectral-type data is described. The method involves absorbance measurements at three wavelengths and the calculation of specific absorbances yielding a hyperbolic relationship between absorbance ratios and analyte concentrations. The concentration of the analyte of known spectrum can be determined in the presence of an interferent or mixture of interferents of unknown concentration(s) and spectra can be determined combining data for different sets of wavelengths. Application to indigo and isatin solutions in DMSO related to the so-called Maya blue problem is reported as an illustr…
Curve resolution procedure for isolating the spectra of unknown interferences from the sample spectrum in analyte determinations
1998
The method described is based on the selection of a wavelength in the sample spectrum that is called ‘reference wavelength’, all measured wavelengths are previously assayed in order to select this reference wavelength. Several wavelengths can be used as the reference. The interferent spectrum is calculated as a function of the interferent absorbance at this wavelength, making use of the ratio between the absorbance of the analyte at the selected wavelength and at every measured wavelength. The proposed methodology can estimate the unknown interferent spectrum from the sample and pure analyte spectra. As a quality guarantee of the estimated spectrum, its shape is also estimated in spiked sam…
Comprehensive analysis of airborne pesticides using hard cap espresso extraction-liquid chromatography-high-resolution mass spectrometry
2017
A hard cap espresso extraction procedure has been developed to recover airborne pesticides in particulate matter trapped in filters. This extraction step was made for 20s at 72°C and 19bar using 50mL of 20% (v/v) acetonitrile in water. After that, based on NaCl salting out, extracts were concentrated 22 times and analysed by ultra-high performance liquid chromatography - high resolution mass spectrometry. 35 pesticides were evaluated, as a proof of concept, being validated the whole methodology and compared the extraction method with that based on microwave assisted extraction for 20min. In short, the method avoids cross-contamination of samples, it is relatively fast and consumes only 10mL…
Trace elemental composition of curry by inductively coupled plasma optical emission spectrometry (ICP-OES)
2008
A methodology based on inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion was developed to determine the content of traces elements in curry samples from the Spanish market. The methodology was validated in terms of accuracy by the analysis of citrus and tomato leaf reference materials achieving comparable results with the certified values. The trace metal content of curry samples was compared with data available from previously published reports concerning Indian samples, especially in terms of heavy metal composition, in order to guarantee the quality of the commercially available spices in the European countries. Values found for th…
Optimization of selenium determination in human milk and whole blood by flow injection hydride atomic absorption spectrometry.
1998
abstract A flow injection hydride atomic absorption spectrometry (FI-HAAS) method was developed for determining selenium in human milk and whole blood after microwave digestion of the sample. The sample (2 mL human milk or 0.25 mL blood) was introduced into the microwave vessel with 1.5 mL HN03 and 0.25 mL H202 and 300 W (4 min) and 600 W (4 min) were applied. The digestion was completed by heating to 140 C (2-3 h). Se (VI) was reduced to Se (IV) with hydrochloric acid. The instrumental conditions for FI-HAAS (concentrations of reducing agent and carrier acid, flow rate of argon carrier gas, and sample volume injected) were optimized. The detection limit of the proposed method was 0.23 ng/m…