Search results for "Wavefront"

showing 10 items of 124 documents

Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.

2012

Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…

AdultMaleCorneal Wavefront AberrationIntraclass correlationZernike polynomialsmedicine.medical_treatmentRefraction Ocularsymbols.namesakeYoung AdultOpticsRefractive surgeryAberrometrymedicineHumansProspective StudiesMathematicsWavefrontObserver VariationReproducibilitybusiness.industryAberrometryReproducibility of ResultsRepeatabilityWavefront sensorMiddle AgedRefractive ErrorsOphthalmologysymbolsOptometryFemalebusinessAmerican journal of ophthalmology
researchProduct

The effect of aberrations on objectively assessed image quality and depth of focus

2017

The effects of aberrations on image quality and the objectively assessed depth of focus (DoF) were studied. Aberrometry data from 80 young subjects with a range of refractive errors was used for computing the visual Strehl ratio based on the optical transfer function (VSOTF), and then, through-focus simulations were performed in order to calculate the objective DoF (using two different relative thresholds of 50% and 80%; and two different pupil diameters) and the image quality (the peak VSOTF). Both lower order astigmatism and higher order aberration (HOA) terms up to the fifth radial order were considered. The results revealed that, of the HOAs, the comatic terms (third and fifth order) ex…

AdultMaleDepth of focusCorneal Wavefront AberrationAdolescentImage qualityPopulationVisual AcuityComa (optics)Astigmatism050105 experimental psychologyYoung Adult03 medical and health sciences0302 clinical medicineOpticsOptical transfer functionAberrometrymedicineHumansComputer Simulation0501 psychology and cognitive scienceseducationVision OcularRetrospective StudiesMathematicsDepth Perceptioneducation.field_of_studybusiness.industryAberrometry05 social sciencesAstigmatismStrehl ratiomedicine.diseaseSensory SystemsOphthalmologyVisual Perception030221 ophthalmology & optometryFemalebusinessJournal of Vision
researchProduct

Optical factors influencing the amplitude of accommodation

2017

AbstractThe purpose of this work was to find plausible predictors among optical parameters that may explain the inter-individual differences in subjective amplitude of accommodation not explained by age. An exploratory multivariable regression analysis was carried out retrospectively on a dataset with 180 eyes from 97 subjects (ages ranged from 20 to 58years). Subjective amplitudes of accommodation were recorded with the use of a custom-made Badal system. A commercial aberrometer was used to obtain each eye’s wavefront during the full range of accommodation. The plausible predictors under study were pupil diameter in the unaccommodated eye, its reduction with accommodation; fourth- and six-…

AdultMaleDepth of focusmedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresZernike polynomialsAmplitude of accommodationAudiologyRefraction Ocular050105 experimental psychologyYoung Adult03 medical and health sciencessymbols.namesake0302 clinical medicineOpticsAberrometrymedicineHumans0501 psychology and cognitive sciencesSpherical aberrationRetrospective Studiesbusiness.industryAberrometry05 social sciencesAccommodation OcularPupilPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseSubjective refractioneye diseasesAmplitude of accommodationSensory SystemsStatistical modelingSpherical aberrationOphthalmologyAmplitude030221 ophthalmology & optometrysymbolsRegression AnalysisFemalePsychologybusinessAccommodationVision Research
researchProduct

Accommodative stimulus-response curves to low-pass filtered natural images

2018

To assess how the monocular steady-state accommodative stimulus-response curve is modified when viewing low-pass filtered natural images. Eighteen adult subjects participated in the study. The accommodative stimulus-response curve was objectively assessed by means of a Hartmann-Shack wavefront sensor. Measurements were taken at different accommodative demands. Target images were low-pass filtered versions of a natural image that were obtained applying different digital spatial filters that limited the spatial frequency content of the natural image. Cutoff spatial frequencies were set at 30, 21, and 15 cycles per degree (cy/deg). Mean data obtained for each target were fitted to linear model…

AdultMaleLow-pass filterRefraction Ocular050105 experimental psychologyYoung Adult03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineOpticsVision MonocularLinear regressionMyopiaHumansCutoff0501 psychology and cognitive sciencesMathematicsAnalysis of covarianceMonocularbusiness.industry05 social sciencesLinear modelAccommodation OcularWavefront sensorSensory SystemsOphthalmologySpace Perception030221 ophthalmology & optometryFemaleSpatial frequencybusinessPhotic StimulationGraefe's Archive for Clinical and Experimental Ophthalmology
researchProduct

Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery

2013

To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…

AdultMaleOptics and PhotonicsPhakic Intraocular Lensesmedicine.medical_specialtyCorneal Wavefront AberrationAdolescentgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisPhakic intraocular lensContrast SensitivityYoung AdultLens Implantation IntraocularAberrometryMyopiamedicineHumansIn patientPostoperative PeriodImplantable collamer lensbusiness.industryAberrometryLASIKGeneral Medicineeye diseasesSurgeryOphthalmologySpherical aberrationOptometryFemaleLasers ExcimerbusinessEuropean Journal of Ophthalmology
researchProduct

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct

Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creatio…

2010

Purpose To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Setting Private practice refractive surgery center, Valencia, Spain. Design Comparative case series. Methods Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were …

AdultMaleVisual acuityCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentCorneal StromaKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSurgical FlapsYoung AdultPostoperative ComplicationsMicrokeratomeRefractive surgeryCorneamedicineMyopiaHumansProspective Studiesmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyMiddle AgedCorneal topographyeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structurePrivate practiceOptometrySurgeryFemalesense organsmedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Human eyes do not need monochromatic aberrations for dynamic accommodation

2017

Purpose To determine if human accommodation uses the eye's own monochromatic aberrations to track dynamic accommodative stimuli. Methods Wavefront aberrations were measured while subjects monocularly viewed a monochromatic Maltese cross moving sinusoidally around 2D of accommodative demand with 1D amplitude at 0.2 Hz. The amplitude and phase (delay) of the accommodation response were compared to the actual vergence of the stimulus to obtain gain and temporal phase, calculated from wavefront aberrations recorded over time during experimental trials. The tested conditions were as follows: Correction of all the subject's aberrations except defocus (C); Correction of all the subject's aberratio…

AdultMaledirectional cuesgenetic structuresVisual AcuityRefraction Ocular01 natural sciencesdynamic accommodation010309 opticsYoung Adult03 medical and health sciences0302 clinical medicineOpticsmonochromatic aberrations0103 physical sciencesHumansWavefrontPhysicsdefocusbusiness.industryAccommodation OcularAstigmatismOriginal ArticlesConvergence Oculareye diseasesSensory SystemsOphthalmologySpherical aberrationAmplitude030221 ophthalmology & optometryFemaleOriginal Articlesense organsMonochromatic colorbusinessAccommodationPhotic StimulationOptometryOphthalmic and Physiological Optics
researchProduct

Accommodation Responds to Optical Vergence and Not Defocus Blur Alone.

2017

Purpose To determine whether changes in wavefront spherical curvature (optical vergence) are a directional cue for accommodation. Methods Nine subjects participated in this experiment. The accommodation response to a monochromatic target was measured continuously with a custom-made adaptive optics system while astigmatism and higher-order aberrations were corrected in real time. There were two experimental open-loop conditions: vergence-driven condition, where the deformable mirror provided sinusoidal changes in defocus at the retina between -1 and +1 diopters (D) at 0.2 Hz; and blur-driven condition, in which the level of defocus at the retina was always 0 D, but a sinusoidal defocus blur …

AdultMalegenetic structuresVisual AcuityVergenceAstigmatismRefraction Ocular050105 experimental psychologyDeformable mirror03 medical and health sciences0302 clinical medicineOpticsmedicineHumans0501 psychology and cognitive sciencesAdaptive opticsDioptreMathematicsWavefrontbusiness.industry05 social sciencesAccommodation OcularAstigmatismConvergence Ocularmedicine.diseaseeye diseases030221 ophthalmology & optometryFemalesense organsMonochromatic colorCuesbusinessAccommodationPhotic StimulationInvestigative ophthalmologyvisual science
researchProduct

Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes

2011

Purpose To evaluate visual acuity, refractive outcomes, and anterior corneal higher-order aberrations (HOAs) after myopic laser in situ keratomileusis (LASIK) with uneventful single femtosecond laser pass versus double pass performed for intraoperative suction loss. Setting Private refractive surgery center, Valencia, Spain. Design Cohort study. Methods After the LASIK flap was created with a single pass of an Intralase femtosecond laser in 1 eye and a double pass in the fellow eye, the ablation was performed with a Visx S2 laser. At 12 months, the refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and anterior corneal HOAs were measured with 4.0 mm and 6.0 mm pup…

AdultMalemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuitygenetic structuresCorneal Stromamedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSurgical Flapslaw.inventionCohort StudiesYoung AdultlawRefractive surgeryOphthalmologyMyopiamedicineHumansDioptreRetrospective Studiesbusiness.industryLASIKMiddle AgedLaserAblationeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeFemtosecondFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct