Search results for "Whole body imaging"

showing 8 items of 28 documents

Whole-body magnetic resonance imaging and FDG-PET/CT for lymphoma staging: Assessment of patient experience

2017

Purpose: To compare patient experience of whole-body MRI and FDG-PET/CT performed for lymphoma staging. Methods: One-hundred-fifteen patients (59 males, 56 females; 53 Hodgkin, 62 non-Hodgkin; mean age: 43.8 years) with lymphoma underwent whole-body MRI and FDG-PET/CT for staging and filled a questionnaire regarding their experience of the examinations using a 4-point Likert scale (1, very good; 4,very bad). Differences were evaluated using Wilcoxon signed-rank test. Patients were asked to express their preference on both techniques. Preferences were compared on the basis of gender, age, and Ann Arbor stage using the chi-square test. A p-value ≤ .05 was considered significant. Results: Most…

Patient experiencelcsh:Medical physics. Medical radiology. Nuclear medicinemedicine.medical_specialtyLymphomaWilcoxon signed-rank testlcsh:R895-920Whole body imagingLymphoma staging030218 nuclear medicine & medical imaging03 medical and health sciencesMagnetic resonance imaging0302 clinical medicinePatient experiencemedicineRadiology Nuclear Medicine and imagingStage (cooking)Whole body imagingmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingmedicine.diseaseLymphomaPositron emission tomography030220 oncology & carcinogenesisRadiologyPositron-emission tomographybusinessThe Egyptian Journal of Radiology and Nuclear Medicine
researchProduct

A 20-channel receive-only mouse array coil for a 3 T clinical MRI system

2011

A 20-channel phased-array coil for MRI of mice has been designed, constructed, and validated with bench measurements and high-resolution accelerated imaging. The technical challenges of designing a small, high density array have been overcome using individual small-diameter coil elements arranged on a cylinder in a hexagonal overlapping design with adjacent low impedance preamplifiers to further decouple the array elements. Signal-to-noise ratio (SNR) and noise amplification in accelerated imaging were simulated and quantitatively evaluated in phantoms and in vivo mouse images. Comparison between the 20-channel mouse array and a length-matched quadrature driven small animal birdcage coil sh…

Physicsmedicine.diagnostic_testPreamplifierPhysics::Medical PhysicsWhole body imagingMagnetic resonance imagingequipment and suppliesLow impedanceImaging phantomTransducerNuclear magnetic resonanceElectromagnetic coilArray coilmedicineRadiology Nuclear Medicine and imagingBiomedical engineeringMagnetic Resonance in Medicine
researchProduct

Synthesis and preliminary in vivo evaluation of well-dispersed biomimetic nanocrystalline apatites labeled with positron emission tomographic imaging…

2015

In recent years, biomimetic synthetic apatite nanoparticles (AP-NPs), having chemical similarity with the mineral phase of bone, have attracted a great interest in nanomedicine as potential drug carriers. To evaluate the therapeutic perspectives of AP-NPs through the mechanisms of action and organs they interact with, the noninvasive monitoring of their in vivo behavior is of paramount importance. To this aim, here the feasibility to radiolabel AP-NPs ("naked" and surface-modified with citrate to reduce their aggregation) with two positron emission tomographic (PET) imaging agents ([F-18]NaF and Ga-68-NO(2)AP(BP)) was investigated. [F-18]NaF was used for the direct incorporation of the radi…

inorganic chemicalsMalepositron emission tomographyMaterials scienceNanoparticleNanotechnologyPilot ProjectsDiffusionNanocapsulesIn vivoBiomimetic MaterialsApatitesMaterials TestingmedicineAnimalsGeneral Materials ScienceChelationWhole Body ImagingColloidsParticle SizeRats Wistarmedicine.diagnostic_testtechnology industry and agriculturenanomedicinecalcium phosphatesPositron emission tomographyIsotope LabelingPositron-Emission Tomographydrug deliveryDrug deliverySurface modificationNanomedicineFeasibility StudiesNanoparticlesRadiopharmaceuticalsDrug carrierCrystallizationACS applied materialsinterfaces
researchProduct

Retrospective Analysis of Whole-Body Magnetic Resonance Imaging of Bone Manifestations in Long-Term Treated Patients with Gaucher Disease Type 1

2018

We retrospectively assessed bone and visceral manifestations in patients with Gaucher disease type 1 (GD1) with whole-body magnetic resonance imaging (WB-MRI) to determine the effects of different timing in initiating long-term enzyme replacement therapy.In 17 patients with GD1, we performed 2 WB-MRI examinations at a median interval of 13 months. Patients had received enzyme replacement therapy with alglucerase/imiglucerase for a median of 13 years prior to the first examination. MRI results were retrospectively stratified based on treatment initiation into 2 groups: "early" (age ≤12 years, median 5 years) and "late" (during adulthood, median 32 years). We evaluated occurrence of irreversi…

medicine.medical_specialtyImiglucerase030232 urology & nephrologyDiseaseSeverity of Illness Index03 medical and health sciences0302 clinical medicineBone MarrowAlglucerase030225 pediatricsmedicineRetrospective analysisHumansEnzyme Replacement TherapyWhole Body ImagingRetrospective StudiesGaucher Diseasemedicine.diagnostic_testbusiness.industryOsteonecrosisMagnetic resonance imagingRetrospective cohort studyEnzyme replacement therapyMagnetic Resonance ImagingRecombinant ProteinsSurgeryTreatment OutcomePediatrics Perinatology and Child HealthGlucosylceramidaseWhole bodybusinessmedicine.drugKlinische Pädiatrie
researchProduct

Whole body magnetic resonance in indolent lymphomas under watchful waiting: The time is now.

2017

The indolent non-Hodgkin lymphomas (i-NHLs) are characterised by ‘indolent’ clinical behaviour with slow growth and prolonged natural history. The watchful waiting (WW) strategy is a frequently employed treatment option in these patients. This implies a strict monitoring by imaging examinations, including 18F-fluorodeoxyglucose-positron emission tomography/computed tomography (18F-FDG-PET/CT) and CT. A major concern is radiation exposure due to regularly monitoring by conventional imaging procedures. Several studies have demonstrated the reliability of whole-body magnetic resonance imaging (WB-MRI) for lymphoma staging. WB-MRI could be useful for active surveillance in i-NHLs providing the …

medicine.medical_specialtyLymphomamedicine.medical_treatmentWhole body imaging030218 nuclear medicine & medical imaging03 medical and health sciencesMagnetic resonance imaging0302 clinical medicineimmune system diseaseshemic and lymphatic diseasesmedicinemedia_common.cataloged_instanceHumansRadiology Nuclear Medicine and imagingWhole Body ImagingEuropean unionWatchful WaitingNeuroradiologymedia_commonmedicine.diagnostic_testbusiness.industryLymphoma Non-HodgkinReproducibility of ResultsMagnetic resonance imagingInterventional radiologyGeneral Medicinemedicine.diseaseLymphomaRadiation therapyDiffusion Magnetic Resonance Imaging030220 oncology & carcinogenesisDisease ProgressionIonising radiationRadiologybusinessWatchful waitingEuropean radiology
researchProduct

Pitfalls in whole body MRI with diffusion weighted imaging performed on patients with lymphoma: What radiologists should know

2016

The technological advances in radiological imaging and the relevance of a diagnostic tool that may reduce radiation-induced long-term effects have led to a widespread use of whole body magnetic resonance imaging (WB-MRI) with diffusion weighted imaging for oncologic patients. A lot of studies demonstrated the feasibility and reliability of WB-MRI as an alternative technique for lymphoma staging and response assessment during and after treatment. In this paper, taking advantage of our 2years of experience using WB-MRI for lymphoma, we discuss the main pitfalls and artifacts radiologists should know examining a WB-MRI performed on this typology of patients in order to avoid images misinterpre…

medicine.medical_specialtyRadiology Nuclear Medicine and ImagingLymphomaWhole body mriBiophysicsBiomedical EngineeringPitfall030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineMagnetic resonance imagingRadiologistsHumansMedicineEffective diffusion coefficientWhole Body ImagingMedical physicsDiagnostic ErrorsRadiological imagingmedicine.diagnostic_testbusiness.industryReproducibility of ResultsMagnetic resonance imagingDiffusion weighted imagingmedicine.diseaseOncologic imagingLymphomaResponse assessmentDiffusion Magnetic Resonance ImagingBiophysic030220 oncology & carcinogenesisArtifactClinical CompetenceRadiologyArtifactsbusinessWhole bodySettore MED/36 - Diagnostica Per Immagini E RadioterapiaDiffusion MRI
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct

Whole-body magnetic resonance imaging (WB-MRI) in oncology: an Italian survey.

2019

Purpose: To perform a survey among all members of the Italian Society of Medical and Interventional Radiology (SIRM) to assess how whole-body MRI (WB-MRI) is performed in oncologic patients in Italy. Methods: On March 2019, we administered an online poll to all SIRM members about their use of WB-MRI in 2018 asking 15 questions regarding oncologic indications, imaging protocol, use of contrast media, experience in WB-MRI, duration of scan time and reporting time. Results: Forty-eight members participated to the survey. WB-MRIs/total MRIs ratio was 1%. Lymphoma was the most common indication (17/48, 35%), followed by myeloma and prostate cancer, with these three tumors representing the most c…

medicine.medical_specialtyWhole body imagingContrast MediaGadolinium030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancer0302 clinical medicineBreast cancerNeoplasmsSurveys and QuestionnairesmedicineHumansRadiology Nuclear Medicine and imagingWhole Body ImagingPractice Patterns Physicians'CancerNeuroradiologyWhole-body imagingmedicine.diagnostic_testbusiness.industryCancerInterventional radiologyMagnetic resonance imagingGeneral Medicinemedicine.diseaseMagnetic Resonance ImagingItaly030220 oncology & carcinogenesisDiffusion-weighted imagingRadiologybusinessDiffusion MRILa Radiologia medica
researchProduct